SIMCOM support
Hello folks,
I cleaned my work on the SIMCOM plugin according to Denis' suggestions and add some new quirks. The patches will follow this mail.
Moreover, I have two new questions:
- In my patches, I had to add a function in src/network.c to be able
to report a new network technology. I was surprised that the function didn't exist. Maybe there are an other mecanism which I didn't see to change the network technology and send the dbus signal ?
- I see in mail sent by Jesper Larsen a patch about configuration of
the serial port. The patch adds the option "Read" to "on". I didn't understand the behaviour of this option. What do this option make ?
Have a good holidays,
Regards,
Anthony V.
Signature · 8 lines
----------------------------------------- Viallard Anthony (+41 024 455 24 82) [ Embedded System | Software Designer ] ----------------------------------------- Syscom Instruments SA Rue de l'industrie 21 1450 Sainte-Croix -----------------------------------------
Quoted 7 lines · Viallard Anthony
Hello folks,
I cleaned my work on the SIMCOM plugin according to Denis' suggestions and add some new quirks. The patches will follow this mail.
Moreover, I have two new questions:
Quoted 8 lines
- In my patches, I had to add a function in
src/network.cto be able to
report a new network technology. I was surprised that the function didn't exist. Maybe there are an other mecanism which I didn't see to change the network technology and send the dbus signal ?
- I see in mail sent by Jesper Larsen a patch about configuration of the
serial port. The patch adds the option "Read" to "on". I didn't understand the behaviour of this option. What do this option make ?
It sets the CREAD flag in the termios structure applied to the tty (
http://linux.die.net/man/3/termios). The man page merely says that what it does is "Enable receiver". Without it I didn't get any reply from the module to AT commands.
Quoted 20 lines
Have a good holidays,
Regards,
Anthony V.--
------------------------------**-----------
Viallard Anthony (+41 024 455 24 82)
[ Embedded System | Software Designer ]
------------------------------**-----------
Syscom Instruments SA
Rue de l'industrie 21
1450 Sainte-Croix
------------------------------**-----------
______________________________**_________________
ofono mailing list
ofono(a)ofono.org
https://lists.ofono.org/**mailman/listinfo/ofono<https://lists.ofono.org/mailman/listinfo/ofono>