Skip to contentSkip to conversation

:dt-binding:Documents the mbigen bindings

PATCH Superseded majun (F) 2 participants 3 messages May 30, 2015 – Jun 2, 2015 Device tree bindings

v1 of 10 Superseded Latest is v10 →

lore
Share & tools
lore

majun (F)

author
#0 lore raw

PATCH 4/4 :dt-binding:Documents the mbigen bindings

Add the mbigen msi interrupt controller bindings document

---
 Documentation/devicetree/bindings/arm/mbigen.txt |   51 ++++++++++++++++++++++
 1 files changed, 51 insertions(+), 0 deletions(-)
 create mode 100755 Documentation/devicetree/bindings/arm/mbigen.txt
Documentation/devicetree/bindings/arm/mbigen.txt new file +51 -0
new file mode 100755
index 0000000..d442b31
@@ -0,0 +1,51 @@
+Hisilicon mbigen device tree bindings.
+=======================================
+
+Mbigen means: message based interrupt generator.
+
+MBI is kind of msi interrupt only used on Non-PCI devices.
+
+To reduce the wired interrupt number connected to GIC,
+Hisilicon designed mbigen to collect and generate interrupt.
+
+
+Non-pci devices can connect to mbigen and gnerate the inteerrupt
+by wirtting ITS register.
+
+The mbigen and devices connect to mbigen have the following properties:
+
+
+Mbigen required properties:
+-------------------------------------------
+-compatible: Should be "hisilicon,mbi-gen"
+-msi-parent: should specified the ITS mbigen connected
+-interrupt controller: Identifies the node as an interrupt controller
+- #interrupt-cells : Specifies the number of cells needed to encode an
+  interrupt source. The value is 2 for now.
+- reg: Specifies the base physical address and size of the ITS
+  registers.
+
+Examples:
+
+	mbigen_pa: interrupt-controller at 4c030000 {
+			compatible = "hisilicon,mbi-gen";
+			msi-parent = <&its_pa>;
+			interrupt-controller;
+			#interrupt-cells = <2>;
+			reg = <0x4c030000 0x10000>;
+		};
+
+Device connect to mbigen required properties:
+----------------------------------------------------
+-interrupt-parent: Specifies the mbigen node which device connected.
+-interrupts:specifies the interrupt source.The first cell is hwirq num, the
+  second number is trigger type.
+
+Examples:
+	usb0: ehci at a1000000 {
+		compatible = "generic-ehci";
+		interrupt-parent = <&mbigen_pa>;
+		reg = <0xa1000000 0x10000>;
+		interrupts = <20 4>;
+	};
+
Signature · 1 line
1.7.1
#1 lore raw
Quoted 18 lines · majun (F)

Add the mbigen msi interrupt controller bindings document

---
 Documentation/devicetree/bindings/arm/mbigen.txt |   51 ++++++++++++++++++++++
 1 files changed, 51 insertions(+), 0 deletions(-)
 create mode 100755 Documentation/devicetree/bindings/arm/mbigen.txt
Documentation/devicetree/bindings/arm/mbigen.txt new file +3 -0
new file mode 100755
index 0000000..d442b31
@@ -0,0 +1,51 @@
+Hisilicon mbigen device tree bindings.
+=======================================
+

Documentation/devicetree/bindings/arm/mbigen.txt line 13

Quoted 10 lines
Documentation/devicetree/bindings/arm/mbigen.txt new file +10 -0
+Mbigen means: message based interrupt generator.
+
+MBI is kind of msi interrupt only used on Non-PCI devices.
+
+To reduce the wired interrupt number connected to GIC,
+Hisilicon designed mbigen to collect and generate interrupt.
+
+
+Non-pci devices can connect to mbigen and gnerate the inteerrupt
+by wirtting ITS register.

Typos.

Documentation/devicetree/bindings/arm/mbigen.txt line 24

Quoted 11 lines
Documentation/devicetree/bindings/arm/mbigen.txt new file +11 -0
+
+The mbigen and devices connect to mbigen have the following properties:
+
+
+Mbigen required properties:
+-------------------------------------------
+-compatible: Should be "hisilicon,mbi-gen"
+-msi-parent: should specified the ITS mbigen connected
+-interrupt controller: Identifies the node as an interrupt controller
+- #interrupt-cells : Specifies the number of cells needed to encode an
+  interrupt source. The value is 2 for now.

The precise format of these cells needs to be specified, at this point in the binding document.

Why do you say "The value is 2 for now"? Do you expect this to grow in future? If so, why?

Documentation/devicetree/bindings/arm/mbigen.txt line 26

Quoted 2 lines
Documentation/devicetree/bindings/arm/mbigen.txt new file +2 -0
+- reg: Specifies the base physical address and size of the ITS
+  registers.

This doesn't sound right. This isn't the ITS, so it shouldn't refer to the ITS registers in this manner.

Does the mbigen not have its own set of registers?

Thanks,
Mark.

Quoted 29 lines
Documentation/devicetree/bindings/arm/mbigen.txt new file +25 -0
+
+Examples:
+
+	mbigen_pa: interrupt-controller at 4c030000 {
+			compatible = "hisilicon,mbi-gen";
+			msi-parent = <&its_pa>;
+			interrupt-controller;
+			#interrupt-cells = <2>;
+			reg = <0x4c030000 0x10000>;
+		};
+
+Device connect to mbigen required properties:
+----------------------------------------------------
+-interrupt-parent: Specifies the mbigen node which device connected.
+-interrupts:specifies the interrupt source.The first cell is hwirq num, the
+  second number is trigger type.
+
+Examples:
+	usb0: ehci at a1000000 {
+		compatible = "generic-ehci";
+		interrupt-parent = <&mbigen_pa>;
+		reg = <0xa1000000 0x10000>;
+		interrupts = <20 4>;
+	};
+
Signature · 1 line
1.7.1
author
#2 lore raw

? 2015/6/1 18:04, Mark Rutland ??:

Quoted 32 lines · majun (F)
Quoted 18 lines

Add the mbigen msi interrupt controller bindings document

---
 Documentation/devicetree/bindings/arm/mbigen.txt |   51 ++++++++++++++++++++++
 1 files changed, 51 insertions(+), 0 deletions(-)
 create mode 100755 Documentation/devicetree/bindings/arm/mbigen.txt
Documentation/devicetree/bindings/arm/mbigen.txt new file +3 -0
new file mode 100755
index 0000000..d442b31
@@ -0,0 +1,51 @@
+Hisilicon mbigen device tree bindings.
+=======================================
+

Documentation/devicetree/bindings/arm/mbigen.txt line 13

Quoted 10 lines
Documentation/devicetree/bindings/arm/mbigen.txt new file +10 -0
+Mbigen means: message based interrupt generator.
+
+MBI is kind of msi interrupt only used on Non-PCI devices.
+
+To reduce the wired interrupt number connected to GIC,
+Hisilicon designed mbigen to collect and generate interrupt.
+
+
+Non-pci devices can connect to mbigen and gnerate the inteerrupt
+by wirtting ITS register.

Typos.

Quoted 15 lines

Documentation/devicetree/bindings/arm/mbigen.txt line 24

Quoted 11 lines
Documentation/devicetree/bindings/arm/mbigen.txt new file +11 -0
+
+The mbigen and devices connect to mbigen have the following properties:
+
+
+Mbigen required properties:
+-------------------------------------------
+-compatible: Should be "hisilicon,mbi-gen"
+-msi-parent: should specified the ITS mbigen connected
+-interrupt controller: Identifies the node as an interrupt controller
+- #interrupt-cells : Specifies the number of cells needed to encode an
+  interrupt source. The value is 2 for now.

The precise format of these cells needs to be specified, at this point in the binding document.

ok, i will fix this in next version

Quoted 3 lines

Why do you say "The value is 2 for now"? Do you expect this to grow in future? If so, why?

Because the hardware design will be changed in the near future, to compatible with these chips, this value need to change either.

Quoted 11 lines

Documentation/devicetree/bindings/arm/mbigen.txt line 26

Quoted 2 lines
Documentation/devicetree/bindings/arm/mbigen.txt new file +2 -0
+- reg: Specifies the base physical address and size of the ITS
+  registers.

This doesn't sound right. This isn't the ITS, so it shouldn't refer to the ITS registers in this manner.

Does the mbigen not have its own set of registers?

Thanks,
Mark.

yes, you are right, it should be mbigen register.

Quoted 32 lines
Quoted 29 lines
Documentation/devicetree/bindings/arm/mbigen.txt new file +25 -0
+
+Examples:
+
+	mbigen_pa: interrupt-controller at 4c030000 {
+			compatible = "hisilicon,mbi-gen";
+			msi-parent = <&its_pa>;
+			interrupt-controller;
+			#interrupt-cells = <2>;
+			reg = <0x4c030000 0x10000>;
+		};
+
+Device connect to mbigen required properties:
+----------------------------------------------------
+-interrupt-parent: Specifies the mbigen node which device connected.
+-interrupts:specifies the interrupt source.The first cell is hwirq num, the
+  second number is trigger type.
+
+Examples:
+	usb0: ehci at a1000000 {
+		compatible = "generic-ehci";
+		interrupt-parent = <&mbigen_pa>;
+		reg = <0xa1000000 0x10000>;
+		interrupts = <20 4>;
+	};
+
Signature · 1 line