We have an issue where lustre servers and clients cannot talk to each other. There are about 11,000 clients all trying to connect to a server that just been rebooted (nbp6-oss3 in this example)

pfe21 is a lustre client thats trying to remount the filesystem from nbp6-oss3.

running rping server on pfe21 hangs and waits until the client tried to connect, then it prints out debug information up to cq_thread started. and hangs there, for a minute or so until issuing the two UNREACHABLE errors:

pfe21 ~ # rping -v -s -d -P -p2 -a 10.151.27.19
port 2
created cm_id 0x60e350
rdma_bind_addr successful
rdma_listen
cma_event type RDMA_CM_EVENT_CONNECT_REQUEST cma_id 0x60b620 (child) child cma 0x60b620
created pd 0x60bd80
created channel 0x60bda0
created cq 0x60bdc0
created qp 0x60bf00
rping_setup_buffers called on cb 0x60b8c0
allocated & registered buffers...
accepting client connection request
cq_thread started.
cma_event type RDMA_CM_EVENT_UNREACHABLE cma_id 0x60b620 (child) cma event RDMA_CM_EVENT_UNREACHABLE, error -110

The rping client is started below. As soon as it starts, it runs up to the point of cq_thread started. Hangs there and eventually times out as well, issuing 4 error messages:

nbp6-oss3 ~ # rping -c -vp-d -S 30 -p 2 -a 10.151.27.19 size 30
port 2
created cm_id 0x60f640
cma_event type RDMA_CM_EVENT_ADDR_RESOLVED cma_id 0x60f640 (parent) cma_event type RDMA_CM_EVENT_ROUTE_RESOLVED cma_id 0x60f640 (parent) rdma_resolve_addr - rdma_resolve_route successful
created pd 0x60ab10
created channel 0x60ab30
created cq 0x60ab50
created qp 0x60ac60
rping_setup_buffers called on cb 0x6072e0
allocated & registered buffers...
cq_thread started.
cma_event type RDMA_CM_EVENT_UNREACHABLE cma_id 0x60f640 (parent) cma event RDMA_CM_EVENT_UNREACHABLE, error -110
wait for CONNECTED state 4
connect error -1

Any ideas? The neighbor entries on both side were in a reachable state before the test. And the two systems did manage to find one another. Keep in mind that when this is going on, 11,000+ clients are trying to connect to nbp6-oss3

Normally lustre mounts fine and rping have no issues. We have noticed some neighbor resolution issues and are considering ucast_solicit, mcast_solicit, and unres_qlen changes because we also occationally experience issues with icmp ping. Its typically been the experience that changing these configs have little effect. Yes its probably the case that unicast arp refresh has long failed and 11,000+ clients may be multicasting for
for arp.

Any help or insight greatly appreciated.

thx, bob

--
To unsubscribe from this list: send the line "unsubscribe linux-rdma" in the body of a message to [email protected] More majordomo info at http://vger.kernel.org/majordomo-info.html

A message that is not in the archive (sent off-list or not yet received): [email protected]

#2 lore raw
Quoted 74 lines · Bob Ciotti

We have an issue where lustre servers and clients cannot talk to each other.
There are about 11,000 clients all trying to connect to a server that just been rebooted
(nbp6-oss3 in this example)

pfe21 is a lustre client thats trying to remount the filesystem from nbp6-oss3.

running rping server on pfe21 hangs and waits until the client tried to connect, then it prints out
debug information up to cq_thread started. and hangs there, for a minute or so until issuing the two UNREACHABLE errors:

pfe21 ~ # rping -v -s -d -P -p2 -a 10.151.27.19
port 2
created cm_id 0x60e350
rdma_bind_addr successful
rdma_listen
cma_event type RDMA_CM_EVENT_CONNECT_REQUEST cma_id 0x60b620 (child) child cma 0x60b620
created pd 0x60bd80
created channel 0x60bda0
created cq 0x60bdc0
created qp 0x60bf00
rping_setup_buffers called on cb 0x60b8c0
allocated & registered buffers...
accepting client connection request
cq_thread started.
cma_event type RDMA_CM_EVENT_UNREACHABLE cma_id 0x60b620 (child) cma event RDMA_CM_EVENT_UNREACHABLE, error -110

The rping client is started below. As soon as it starts, it runs up to the point
of cq_thread started. Hangs there and eventually times out as well, issuing 4 error
messages:

nbp6-oss3 ~ # rping -c -vp-d -S 30 -p 2 -a 10.151.27.19 size 30
port 2
created cm_id 0x60f640
cma_event type RDMA_CM_EVENT_ADDR_RESOLVED cma_id 0x60f640 (parent) cma_event type RDMA_CM_EVENT_ROUTE_RESOLVED cma_id 0x60f640 (parent) rdma_resolve_addr - rdma_resolve_route successful
created pd 0x60ab10
created channel 0x60ab30
created cq 0x60ab50
created qp 0x60ac60
rping_setup_buffers called on cb 0x6072e0
allocated & registered buffers...
cq_thread started.
cma_event type RDMA_CM_EVENT_UNREACHABLE cma_id 0x60f640 (parent) cma event RDMA_CM_EVENT_UNREACHABLE, error -110
wait for CONNECTED state 4
connect error -1

Any ideas? The neighbor entries on both side were in a reachable state before the test. And the two systems did manage to find one another. Keep in mind that when this
is going on, 11,000+ clients are trying to connect to nbp6-oss3

Normally lustre mounts fine and rping have no issues. We have noticed some neighbor resolution issues and are considering ucast_solicit, mcast_solicit, and unres_qlen changes
because we also occationally experience issues with icmp ping. Its typically been the experience that changing these configs have little effect. Yes its probably the case that
unicast arp refresh has long failed and 11,000+ clients may be multicasting for
for arp.

Quoted 1 line

Any help or insight greatly appreciated.

RDMA_CM_EVENT_UNREACHABLE is indicated when there are timeouts in underlying CM protocol exchange. I suspect that the server is really busy and doesn't respond to the low level CM MADs in a timely manner. RDMA CM (and other kernel ULPs like IPoIB and SRP use hard coded local and remote response timeouts of 20 which is ~4.3 sec. This was discussed back in 2006 in
http://comments.gmane.org/gmane.linux.drivers.openib/27664. In this scenario, the response took more than 30 seconds. More recently, there was proposal to base RDMA CM response timeout on subnet timeout
(http://permalink.gmane.org/gmane.linux.drivers.rdma/19969).

HTH,
Hal

Quoted 10 lines

thx, bob

Signature · 3 lines
To unsubscribe from this list: send the line "unsubscribe linux-rdma" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html

--
To unsubscribe from this list: send the line "unsubscribe linux-rdma" in the body of a message to [email protected] More majordomo info at http://vger.kernel.org/majordomo-info.html

A message that is not in the archive (sent off-list or not yet received): 55783D21.1050104-LDSdmyG8hGV8YrgS2mwiifqBs+8SCbDb@public.gmane.org

#4 lore raw

PiBSRE1BX0NNX0VWRU5UX1VOUkVBQ0hBQkxFIGlzIGluZGljYXRlZCB3aGVuIHRoZXJlIGFyZSB0 aW1lb3V0cyBpbg0KPiB1bmRlcmx5aW5nIENNIHByb3RvY29sIGV4Y2hhbmdlLiBJIHN1c3BlY3Qg dGhhdCB0aGUgc2VydmVyIGlzIHJlYWxseQ0KPiBidXN5IGFuZCBkb2Vzbid0IHJlc3BvbmQgdG8g dGhlIGxvdyBsZXZlbCBDTSBNQURzIGluIGEgdGltZWx5IG1hbm5lci4NCj4gUkRNQSBDTSAoYW5k IG90aGVyIGtlcm5lbCBVTFBzIGxpa2UgSVBvSUIgYW5kIFNSUCB1c2UgaGFyZCBjb2RlZCBsb2Nh bA0KPiBhbmQgcmVtb3RlIHJlc3BvbnNlIHRpbWVvdXRzIG9mIDIwIHdoaWNoIGlzIH40LjMgc2Vj LiBUaGlzIHdhcyBkaXNjdXNzZWQNCj4gYmFjayBpbiAyMDA2IGluDQo+IGh0dHA6Ly9jb21tZW50 cy5nbWFuZS5vcmcvZ21hbmUubGludXguZHJpdmVycy5vcGVuaWIvMjc2NjQuIEluIHRoaXMNCj4g c2NlbmFyaW8sIHRoZSByZXNwb25zZSB0b29rIG1vcmUgdGhhbiAzMCBzZWNvbmRzLiAgTW9yZSBy ZWNlbnRseSwgdGhlcmUNCj4gd2FzIHByb3Bvc2FsIHRvIGJhc2UgUkRNQSBDTSByZXNwb25zZSB0 aW1lb3V0IG9uIHN1Ym5ldCB0aW1lb3V0DQo+IChodHRwOi8vcGVybWFsaW5rLmdtYW5lLm9yZy9n bWFuZS5saW51eC5kcml2ZXJzLnJkbWEvMTk5NjkpLg0KDQpIYWwncyBhc3Nlc3NtZW50IHNlZW1z IGxpa2VseS4gIEVycm9yIGNvZGUgLTExMCBpcyBFVElNRURPVVQuICBIb3dldmVyLCB0aGUgSUIg Q00gdGltZW91dCB3aGVuIHVzZWQgdGhyb3VnaCB0aGUgUkRNQSBDTSBzaG91bGQgYmUgbXVjaCBs YXJnZXIsIGFzIGl0IG1ha2VzIHVzZSBvZiB0aGUgQ00gTVJBIHByb3RvY29sLiAgVW5sZXNzIGEg bG90IG9mIE1BRHMgYXJlIGJlaW5nIGxvc3QsIG9yIEknbSBub3QgcmVtZW1iZXJpbmcgdGhlIFJE TUEgQ00gY29kZSBjb3JyZWN0bHksIHRoZXJlJ3Mgc3RpbGwgYW4gaXNzdWUgaGVyZSB0aGF0IEkn bSBub3QgdW5kZXJzdGFuZGluZy4NCg0KLSBTZWFuDQo=
--
To unsubscribe from this list: send the line "unsubscribe linux-rdma" in the body of a message to [email protected] More majordomo info at http://vger.kernel.org/majordomo-info.html

author
#5 lore raw
In reply to a message not in the archive
Quoted 88 lines · Hal Rosenstock
Quoted 74 lines · Bob Ciotti

We have an issue where lustre servers and clients cannot talk to each other.
There are about 11,000 clients all trying to connect to a server that just been rebooted
(nbp6-oss3 in this example)

pfe21 is a lustre client thats trying to remount the filesystem from nbp6-oss3.

running rping server on pfe21 hangs and waits until the client tried to connect, then it prints out
debug information up to cq_thread started. and hangs there, for a minute or so until issuing the two UNREACHABLE errors:

pfe21 ~ # rping -v -s -d -P -p2 -a 10.151.27.19
port 2
created cm_id 0x60e350
rdma_bind_addr successful
rdma_listen
cma_event type RDMA_CM_EVENT_CONNECT_REQUEST cma_id 0x60b620 (child) child cma 0x60b620
created pd 0x60bd80
created channel 0x60bda0
created cq 0x60bdc0
created qp 0x60bf00
rping_setup_buffers called on cb 0x60b8c0
allocated & registered buffers...
accepting client connection request
cq_thread started.
cma_event type RDMA_CM_EVENT_UNREACHABLE cma_id 0x60b620 (child) cma event RDMA_CM_EVENT_UNREACHABLE, error -110

The rping client is started below. As soon as it starts, it runs up to the point
of cq_thread started. Hangs there and eventually times out as well, issuing 4 error
messages:

nbp6-oss3 ~ # rping -c -vp-d -S 30 -p 2 -a 10.151.27.19 size 30
port 2
created cm_id 0x60f640
cma_event type RDMA_CM_EVENT_ADDR_RESOLVED cma_id 0x60f640 (parent) cma_event type RDMA_CM_EVENT_ROUTE_RESOLVED cma_id 0x60f640 (parent) rdma_resolve_addr - rdma_resolve_route successful
created pd 0x60ab10
created channel 0x60ab30
created cq 0x60ab50
created qp 0x60ac60
rping_setup_buffers called on cb 0x6072e0
allocated & registered buffers...
cq_thread started.
cma_event type RDMA_CM_EVENT_UNREACHABLE cma_id 0x60f640 (parent) cma event RDMA_CM_EVENT_UNREACHABLE, error -110
wait for CONNECTED state 4
connect error -1

Any ideas? The neighbor entries on both side were in a reachable state before the test. And the two systems did manage to find one another. Keep in mind that when this
is going on, 11,000+ clients are trying to connect to nbp6-oss3

Normally lustre mounts fine and rping have no issues. We have noticed some neighbor resolution issues and are considering ucast_solicit, mcast_solicit, and unres_qlen changes
because we also occationally experience issues with icmp ping. Its typically been the experience that changing these configs have little effect. Yes its probably the case that
unicast arp refresh has long failed and 11,000+ clients may be multicasting for
for arp.

Quoted 1 line

Any help or insight greatly appreciated.

RDMA_CM_EVENT_UNREACHABLE is indicated when there are timeouts in underlying CM protocol exchange. I suspect that the server is really busy and doesn't respond to the low level CM MADs in a timely manner. RDMA CM (and other kernel ULPs like IPoIB and SRP use hard coded local and remote response timeouts of 20 which is ~4.3 sec. This was discussed back in 2006 in
http://comments.gmane.org/gmane.linux.drivers.openib/27664. In this scenario, the response took more than 30 seconds. More recently, there was proposal to base RDMA CM response timeout on subnet timeout
(http://permalink.gmane.org/gmane.linux.drivers.rdma/19969).

Quoted 6 lines

HTH,
Hal

Quoted 3 lines

thx, bob

Looking more carefully at our configuration, we dropped a module configuration parameter for ib_cm. In the past we set /sys/module/ib_cm/parameters/max_timeout to 24

That change was dropped (maybe intentionally because we found it necessary), so will pick up the default of 21. Since rdma_cm set this based on subnet timeout + 2 made this necessary for some time. Our subnet timeout value is 20, so rdma_cm adds +2 to that value, getting it back to a value of 22 == 1.024 second, instead of the previous 4 seconds. Now, these values seem giant, but its still possible that we could be seeing retry flooding because lustre is persistent. Since rdma_cm bases its timeouts on +2 over subnet, then either we increase subnet timeout or change rdma_cm. This looks like another case where exponential backoff of retries could be beneficial.

bob

(hal/sean - thanks!)
--