Skip to contentSkip to conversation

M-Audio transit: illegal sync type and noise on startup?

DISCUSSION Pierre-Louis Bossart 1 participant 1 message Aug 13, 2015

lore
Share & tools
lore
#0 lore raw

While playing with my M-Audio Transit USB device (0763:2006) I saw a synchronization type that doesn't exist in the USB audio class. I get audio out but often the start is garbled with white noise and cracks. Wondering what's going on.

more /proc/asound/card1/stream0
M-Audio Transit USB at usb-0000:00:14.0-2, full speed : USB Audio

Playback:
Status: Stop
Interface 1

    Altset 1
    Format: S24_3LE
    Channels: 2
    Endpoint: 3 OUT (ADAPTIVE)
    Rates: 48001 - 96000 (continuous)u
  Interface 1
    Altset 2
    Format: S24_3LE
    Channels: 2
    Endpoint: 3 OUT (NONE)  <<<<<<< illegal
    Rates: 8000 - 48000 (continuous)
  Interface 1
    Altset 3
    Format: S16_LE
    Channels: 2
    Endpoint: 3 OUT (ASYNC)
    Rates: 8000 - 48000 (continuous)

The only definitions in the spec are Asynchronous, Adaptive or Synchronous...

lsusb tells me that there seems to be a synch endpoint for this setting:

Endpoint Descriptor:
bLength 9
bDescriptorType 5
bEndpointAddress 0x03 EP 3 OUT
bmAttributes 1
Transfer Type Isochronous
Synch Type None
Usage Type Data
wMaxPacketSize 0x0126 1x 294 bytes
bInterval 1
bRefresh 0
bSynchAddress 131
AudioControl Endpoint Descriptor:
bLength 7
bDescriptorType 37
bDescriptorSubtype 1 (EP_GENERAL)
bmAttributes 0x01
Sampling Frequency
bLockDelayUnits 1 Milliseconds
wLockDelay 100 Milliseconds
Endpoint Descriptor:
bLength 9
bDescriptorType 5
bEndpointAddress 0x83 EP 3 IN
bmAttributes 1
Transfer Type Isochronous
Synch Type None
Usage Type Data
wMaxPacketSize 0x0003 1x 3 bytes
bInterval 1
bRefresh 2
bSynchAddress 0

I couldn't figure out what the code does in this case. I didn't find any sync URBs being retired so wondering if this is considered as a synchronous or asynchronous endpoint based on the additional sync endpoint? Any idea on how to debug further? It looks like there could be a second error in the descriptors: if this is a synchronous endpoint then the sync endpoint is meaningless, and if it is asynchronous then the information on locking time is irrelevant...

Regarding the noise on startup, should a delay be inserted after the mode is set? the spec recommends that the host sends silence periods for adaptive and synchronous modes. I see a set of mdelays being added in the quirks, should a new one be added?

Thanks for any pointers,