ARM Xen Bug #45: Is there a solution?
Hello,
is there a solution for
arm: domain 0 disables clocks which are in fact being used
http://bugs.xenproject.org/xen/bug/45
?
On an ARM based board I have to use 'clk_ignore_unused' preventing that Dom0 disables the UART clock for the console UART configured with console=hvc0.
Best regards
Dirk
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 1 line · Dirk Behme
Hello,
Hello Dirk,
Quoted 10 lines
is there a solution for
arm: domain 0 disables clocks which are in fact being used
http://bugs.xenproject.org/xen/bug/45?
On an ARM based board I have to use '
clk_ignore_unused' preventing that Dom0 disables the UART clock for the console UART configured with console=hvc0.
There is no better solution than passing "clk_ignore_unused" on the kernel command line so far.
Regards,
Signature · 6 lines
Julien Grall _______________________________________________ Xen-devel mailing list [email protected] http://lists.xen.org/xen-devel
Hi Julien,
Quoted 7 lines · Julien Grall
Hello Dirk,
Quoted 5 lines
is there a solution for
arm: domain 0 disables clocks which are in fact being used
http://bugs.xenproject.org/xen/bug/45
Quoted 8 lines
Quoted 5 lines
?
On an ARM based board I have to use '
clk_ignore_unused' preventing that Dom0 disables the UART clock for the console UART configured with console=hvc0.There is no better solution than passing "
clk_ignore_unused" on the kernel command line so far.
What would be the solution for this issue? The
"propagate any clock related properties from the UART node into the Xen hypervisor node"
mentioned in the ticket?
Best regards
Dirk
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 1 line · Dirk Behme
Hi Julien,
Hello Dirk,
Quoted 18 lines · Julien Grall
Quoted 7 lines
Hello Dirk,
Quoted 5 lines
is there a solution for
arm: domain 0 disables clocks which are in fact being used
http://bugs.xenproject.org/xen/bug/45Quoted 8 lines
Quoted 5 lines
?
On an ARM based board I have to use '
clk_ignore_unused' preventing that Dom0 disables the UART clock for the console UART configured with console=hvc0.There is no better solution than passing "
clk_ignore_unused" on the kernel command line so far.
Quoted 6 lines
What would be the solution for this issue? The
"propagate any clock related properties from the UART node into the Xen hypervisor node"
mentioned in the ticket?
That is correct. Xen would copy the property "clocks" of the UART into the hypervisor node.
DOM0 would then parse the clocks associated to this node and mark them as used by Xen (I think CLK_IGNORE_UNUSED could do the job for us).
Regards,
Signature · 6 lines
Julien Grall _______________________________________________ Xen-devel mailing list [email protected] http://lists.xen.org/xen-devel
Hi Julien,
Quoted 31 lines · Julien Grall
Quoted 1 line · Dirk Behme
Hi Julien,
Hello Dirk,
Quoted 24 lines · Julien Grall
Quoted 9 lines
Hello Dirk,
Quoted 7 lines
is there a solution for
arm: domain 0 disables clocks which are in fact being used
http://bugs.xenproject.org/xen/bug/45?
Quoted 7 lines
Quoted 4 lines
On an ARM based board I have to use '
clk_ignore_unused' preventing that
Dom0 disables the UART clock for the console UART configured with console=hvc0.There is no better solution than passing "
clk_ignore_unused" on the kernel command line so far.What would be the solution for this issue? The
"propagate any clock related properties from the UART node into the Xen hypervisor node"
Quoted 7 lines
Quoted 1 line
mentioned in the ticket?
That is correct. Xen would copy the property "clocks" of the UART into the hypervisor node.
DOM0 would then parse the clocks associated to this node and mark them as used by Xen (I think
CLK_IGNORE_UNUSEDcould do the job for us).
I've started to look into this:
I'd think in arm_uart.c in dt_uart_init() after
if ( !dev )
we know the UART node we are looking for. From this we have to read the clock configuration.
To be clarified: How to read the clock configuration? I couldn't find any convenient function dt_device_get_clock() or similar for that.
Now, we have the clocks we are looking for.
These are needed in domain_build.c in make_hypervisor_node(), then.
To be clarified: How to pass the clock configuration from arm_uart.c to domain_build.c (and not break the non-dt / non-ARM platforms)?
Any ideas or comments?
Best regards
Dirk
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 1 line · Dirk Behme
Hi Julien,
Hello Dirk,
Quoted 45 lines · Julien Grall
Quoted 31 lines · Dirk Behme
Quoted 1 line
Hi Julien,
Hello Dirk,
Quoted 24 lines · Julien Grall
Quoted 9 lines
Hello Dirk,
Quoted 7 lines
is there a solution for
arm: domain 0 disables clocks which are in fact being used
http://bugs.xenproject.org/xen/bug/45?
Quoted 7 lines
Quoted 4 lines
On an ARM based board I have to use '
clk_ignore_unused' preventing that
Dom0 disables the UART clock for the console UART configured with console=hvc0.There is no better solution than passing "
clk_ignore_unused" on the kernel command line so far.What would be the solution for this issue? The
"propagate any clock related properties from the UART node into the Xen hypervisor node"
Quoted 7 lines
Quoted 1 line
mentioned in the ticket?
That is correct. Xen would copy the property "clocks" of the UART into the hypervisor node.
DOM0 would then parse the clocks associated to this node and mark them as used by Xen (I think
CLK_IGNORE_UNUSEDcould do the job for us).I've started to look into this:
I'd think in
arm_uart.cindt_uart_init()after
Quoted 7 lines
if ( !dev )
we know the UART node we are looking for. From this we have to read the clock configuration.
To be clarified: How to read the clock configuration? I couldn't find any convenient function
dt_device_get_clock()or similar for that.
Xen does not need to parse the content of the property "clocks" but copy the raw value to the DOM0 DT.
You cand find the value of a property with dt_get_property.
Quoted 9 lines
Now, we have the clocks we are looking for.
These are needed in
domain_build.cinmake_hypervisor_node(), then.To be clarified: How to pass the clock configuration from
arm_uart.ctodomain_build.c(and not break the non-dt / non-ARM platforms)?Any ideas or comments?
All the devices (UART included) used by Xen will return DOMID_XEN when dt_device_used_by is called to the node.
You could use it to collect the clocks of all those devices and gather the value in a single property to be created in the hypervisor node.
Regards,
Signature · 6 lines
Julien Grall _______________________________________________ Xen-devel mailing list [email protected] http://lists.xen.org/xen-devel
Quoted 61 lines · Julien Grall
Quoted 39 lines · Dirk Behme
Quoted 25 lines · Julien Grall
Quoted 24 lines · Dirk Behme
Quoted 9 lines · Julien Grall
Hello Dirk,
Quoted 7 lines
is there a solution for
arm: domain 0 disables clocks which are in fact being used
http://bugs.xenproject.org/xen/bug/45?
Quoted 7 lines
Quoted 4 lines
On an ARM based board I have to use '
clk_ignore_unused' preventing that
Dom0 disables the UART clock for the console UART configured with console=hvc0.There is no better solution than passing "
clk_ignore_unused" on the kernel command line so far.What would be the solution for this issue? The
"propagate any clock related properties from the UART node into the Xen hypervisor node"
Quoted 7 lines
Quoted 1 line
mentioned in the ticket?
That is correct. Xen would copy the property "clocks" of the UART into the hypervisor node.
DOM0 would then parse the clocks associated to this node and mark them as used by Xen (I think
CLK_IGNORE_UNUSEDcould do the job for us).I've started to look into this:
I'd think in
arm_uart.cindt_uart_init()afterQuoted 7 lines
if ( !dev )
we know the UART node we are looking for. From this we have to read the clock configuration.
To be clarified: How to read the clock configuration? I couldn't find any convenient function
dt_device_get_clock()or similar for that.Xen does not need to parse the content of the property "clocks" but copy the raw value to the DOM0 DT.
You cand find the value of a property with
dt_get_property.Quoted 8 lines
Now, we have the clocks we are looking for.
These are needed in
domain_build.cinmake_hypervisor_node(), then.To be clarified: How to pass the clock configuration from
arm_uart.ctodomain_build.c(and not break the non-dt / non-ARM platforms)?
Quoted 7 lines
Quoted 1 line
Any ideas or comments?
All the devices (UART included) used by Xen will return
DOMID_XENwhendt_device_used_byis called to the node.You could use it to collect the clocks of all those devices and gather the value in a single property to be created in the hypervisor node.
Anything like below (untested) [1]?
I'm unhappy about the global variables and the max clocks, though.
Best regards
Dirk
[1]
--- xen/arch/arm/domain_build.c | 24 ++++++++++++++++++++++++ 1 file changed, 24 insertions(+)
xen/arch/arm/domain_build.c +24 -0
@@ -42,6 +42,10 @@ static void __init parse_dom0_mem(const }custom_param ("dom0_mem" , parse_dom0_mem); +#define MAX_DT_CLOCKS 256 +static unsigned char dt_clocks[MAX_DT_CLOCKS ]; +static unsigned int clk_cnt; +//#define DEBUG_DT #ifdef DEBUG_DT
@@ -657,6 +661,10 @@ static int make_hypervisor_node(const stif ( res )return res; + res =fdt_property (fdt,"clocks" , dt_clocks, clk_cnt); +if ( res ) +return res; + res =fdt_end_node (fdt);return res;
@@ -1213,9 +1221,11 @@ static int handle_node(struct domain *d, { /* sentinel */ }, };struct dt_device_node *child; +unsigned int len;int res;const char *name;const char *path; +const char *clocks; path =dt_node_full_name (node);
@@ -1246,6 +1256,20 @@ static int handle_node(struct domain *d,if (dt_device_used_by (node) ==DOMID_XEN ) {DPRINT (" Skip it (used by Xen)\n" ); + +/* +* Remember the clock used by the skipped node +* We add it later to the hypervisor node to make the +* Linux kernel aware of its usage +*/ + clocks =dt_get_property (node,"clocks" , &len); +if ( clk_cnt + len >=MAX_DT_CLOCKS ) { +printk ("Failed to remember the clock node of %s\n" , path); +printk ("Use the Linux kernel command 'clk_ignore_unused'\n" ); +return 0 ; + } +memcpy (&dt_clocks[clk_cnt], clocks, len); + clk_cnt += len;return 0 ; }
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Hello Dirk,
Quoted 5 lines · Dirk Behme
Quoted 4 lines · Julien Grall
Quoted 3 lines · Dirk Behme
Quoted 2 lines · Julien Grall
Quoted 1 line · Dirk Behme
On 23.05.2016 22:15, Julien Grall wrote:
Quoted 8 lines
Quoted 5 lines
All the devices (UART included) used by Xen will return
DOMID_XENwhendt_device_used_byis called to the node.You could use it to collect the clocks of all those devices and gather the value in a single property to be created in the hypervisor node.
Anything like below (untested) [1]?
Yes.
Quoted 1 line
I'm unhappy about the global variables and the max clocks, though.
How about moving those variables in the structure kernel_info?
Quoted 70 lines
Best regards
Dirk
[1]
--- xen/arch/arm/domain_build.c | 24 ++++++++++++++++++++++++ 1 file changed, 24 insertions(+)Index:
xen.git/xen/arch/arm/domain_build.c
===================================================================xen/arch/arm/domain_build.c +24
-0@@ -42,6 +42,10 @@ static void __init parse_dom0_mem(const }custom_param ("dom0_mem" , parse_dom0_mem); +#define MAX_DT_CLOCKS 256 +static unsigned char dt_clocks[MAX_DT_CLOCKS ]; +static unsigned int clk_cnt; +//#define DEBUG_DT #ifdef DEBUG_DT @@ -657,6 +661,10 @@ static int make_hypervisor_node(const stif ( res )return res; + res =fdt_property (fdt,"clocks" , dt_clocks, clk_cnt); +if ( res ) +return res; + res =fdt_end_node (fdt);return res;@@ -1213,9 +1221,11 @@ static int handle_node(struct domain *d, { /* sentinel */ }, };struct dt_device_node *child; +unsigned int len;int res;const char *name;const char *path; +const char *clocks; path =dt_node_full_name (node);@@ -1246,6 +1256,20 @@ static int handle_node(struct domain *d,if (dt_device_used_by (node) ==DOMID_XEN ) {DPRINT (" Skip it (used by Xen)\n" ); + +/* +* Remember the clock used by the skipped node +* We add it later to the hypervisor node to make the +* Linux kernel aware of its usage +*/ + clocks =dt_get_property (node,"clocks" , &len); +if ( clk_cnt + len >=MAX_DT_CLOCKS ) { +printk ("Failed to remember the clock node of %s\n" , path); +printk ("Use the Linux kernel command 'clk_ignore_unused'\n" ); +return 0 ; + } +memcpy (&dt_clocks[clk_cnt], clocks, len); + clk_cnt += len;return 0 ; }
Signature · 6 lines
Julien Grall _______________________________________________ Xen-devel mailing list [email protected] http://lists.xen.org/xen-devel
Quoted 24 lines
Subject: Re: ARM Xen Bug #45: Is there a solution?
Date: Tue, 31 May 2016 11:44:23 +0100
From: Julien Grall <[email protected]>
To: Dirk Behme <[email protected]>, [email protected] <[email protected]>
CC: Stefano Stabellini <[email protected]>, Ian Jackson <[email protected]>Hello Dirk,
Quoted 12 lines · Dirk Behme
Quoted 9 lines · Julien Grall
Quoted 3 lines · Dirk Behme
Quoted 2 lines · Julien Grall
Quoted 1 line · Dirk Behme
On 23.05.2016 22:15, Julien Grall wrote:
All the devices (UART included) used by Xen will return
DOMID_XENwhendt_device_used_byis called to the node.You could use it to collect the clocks of all those devices and gather the value in a single property to be created in the hypervisor node.
Quoted 7 lines
Quoted 1 line
Anything like below (untested) [1]?
Yes.
Quoted 1 line
I'm unhappy about the global variables and the max clocks, though.
How about moving those variables in the structure
kernel_info?
Just for the logs to finish this thread:
https://lists.xen.org/archives/html/xen-devel/2016-06/msg02607.html
http://lists.infradead.org/pipermail/linux-arm-kernel/2016-June/438067.html
Best regards
Dirk