make ATAPI PIO work
If "BSY=0, DRQ=0" condition happens on ATAPI just complete the command as this condition happens for:
* the end of the PIO transfer (ie. REQUEST_SENSE seems to return only 18 of 96 requested bytes)
* unsupported ATAPI commands (ie. REPORT_LUNS)
Signed-off-by Bartlomiej Zolnierkiewicz <[email protected]>
drivers/scsi/libata-core.c +19 -8
@@ -2327,19 +2327,30 @@ } } -/* handle BSY=0, DRQ=0 as error */ -if ((status &ATA_DRQ ) ==0 ) { - ap->pio_task_state =PIO_ST_ERR ; -return ; - } - qc =ata_qc_from_tag (ap, ap->active_tag);assert (qc !=NULL ); -if (is_atapi_taskfile (&qc->tf)) +if (is_atapi_taskfile (&qc->tf)) { +/* no more data to transfer or unsupported ATAPI command */ +if ((status &ATA_DRQ ) ==0 ) { + ap->pio_task_state =PIO_ST_IDLE ; + +ata_irq_on (ap); + +ata_qc_complete (qc, status); +return ; + } +atapi_pio_bytes (qc); -else + }else { +/* handle BSY=0, DRQ=0 as error */ +if ((status &ATA_DRQ ) ==0 ) { + ap->pio_task_state =PIO_ST_ERR ; +return ; + } +ata_pio_sector (qc); + } }static void ata_pio_error (struct ata_port *ap)