Calibration logic assumes that the platform timer (HPET or ACPI PM timer) and the TSC are read at about the same time. This assumption may not hold when a long latency event (e.g. SMI or NMI) occurs between the two reads. Reduce the risk of reading uncorrelated values by doing at least four pairs of reads, using the tuple where the delta between the enclosing TSC reads was smallest. From the fourth iteration onwards bail if the new TSC delta isn't better (smaller) than the best earlier one.
---
Obviously (I think) instead of having both read_{hpet,pmtmr}_and_tsc() the calibration logic could be folded between HPET and PMTMR, at the expense of a couple more indirect calls (which may not be that much of a problem as this is all boot-time only). Really such folding would have been possible already before, just that the amount of duplicate code hasn't been this large so far. IOW if so desired, then perhaps the folding should be a separate prereq patch.
xen/arch/x86/time.c +63 -9
@@ -392,9 +392,36 @@ static u64 read_hpet_count(void)return hpet_read32 (HPET_COUNTER ); } +static uint32_t __init read_hpet_and_tsc (uint64_t *tsc) +{ +uint64_t tsc_prev = *tsc =rdtsc_ordered (), tsc_min = ~0 ; +uint32_t best = best; +unsigned int i; + +for ( i =0 ; ; ++i ) + { +uint32_t hpet =hpet_read32 (HPET_COUNTER ); +uint64_t tsc_cur =rdtsc_ordered (); +uint64_t tsc_delta = tsc_cur - tsc_prev; + +if ( tsc_delta < tsc_min ) + { + tsc_min = tsc_delta; + *tsc = tsc_cur; + best = hpet; + } +else if ( i >2 ) +break ; + + tsc_prev = tsc_cur; + } + +return best; +} +static int64_t __init init_hpet (struct platform_timesource *pts) { -uint64_t hpet_rate, start; +uint64_t hpet_rate, start, end;uint32_t count, target, elapsed;/* * Allow HPET to be setup, but report a frequency of 0 so it's not selected
@@ -466,13 +493,13 @@ static int64_t __init init_hpet(struct p pts->frequency = hpet_rate; - count =hpet_read32 (HPET_COUNTER ); - start =rdtsc_ordered (); + count =read_hpet_and_tsc (&start); target =CALIBRATE_VALUE (hpet_rate);while ( (elapsed =hpet_read32 (HPET_COUNTER ) - count) < target )continue ; + elapsed =read_hpet_and_tsc (&end) - count; -return adjust_elapsed (rdtsc_ordered () - start, elapsed, target); +return adjust_elapsed (end - start, elapsed, target); }static void resume_hpet (struct platform_timesource *pts)
@@ -505,9 +532,36 @@ static u64 read_pmtimer_count(void)return inl (pmtmr_ioport); } +static uint32_t __init read_pmtmr_and_tsc (uint64_t *tsc) +{ +uint64_t tsc_prev = *tsc =rdtsc_ordered (), tsc_min = ~0 ; +uint32_t best = best; +unsigned int i; + +for ( i =0 ; ; ++i ) + { +uint32_t pmtmr =inl (pmtmr_ioport); +uint64_t tsc_cur =rdtsc_ordered (); +uint64_t tsc_delta = tsc_cur - tsc_prev; + +if ( tsc_delta < tsc_min ) + { + tsc_min = tsc_delta; + *tsc = tsc_cur; + best = pmtmr; + } +else if ( i >2 ) +break ; + + tsc_prev = tsc_cur; + } + +return best; +} +static s64 __init init_pmtimer (struct platform_timesource *pts) { -uint64_t start; +uint64_t start, end;uint32_t count, target, mask, elapsed;if ( !pmtmr_ioport || (pmtmr_width !=24 && pmtmr_width !=32 ) )
@@ -516,13 +570,13 @@ static s64 __init init_pmtimer(struct pl pts->counter_bits = pmtmr_width; mask =0xffffffff >> (32 - pmtmr_width); - count =inl (pmtmr_ioport); - start =rdtsc_ordered (); + count =read_pmtmr_and_tsc (&start); target =CALIBRATE_VALUE (ACPI_PM_FREQUENCY ); -while ( (elapsed = (inl (pmtmr_ioport) - count) & mask) < target ) +while ( ((inl (pmtmr_ioport) - count) & mask) < target )continue ; + elapsed =read_pmtmr_and_tsc (&end) - count; -return adjust_elapsed (rdtsc_ordered () - start, elapsed, target); +return adjust_elapsed (end - start, elapsed, target); } static struct platform_timesource __initdata plt_pmtimer =
Quoted 9 lines · Jan Beulich
Calibration logic assumes that the platform timer (HPET or ACPI PM timer) and the TSC are read at about the same time. This assumption may not hold when a long latency event (e.g. SMI or NMI) occurs between the two reads. Reduce the risk of reading uncorrelated values by doing at least four pairs of reads, using the tuple where the delta between the enclosing TSC reads was smallest. From the fourth iteration onwards bail if the new TSC delta isn't better (smaller) than the best earlier one.
Signed-off-by Jan Beulich <[email protected]>
When running virtualized, scheduling in the host would also constitute long latency events. I wonder whether, to compensate for that, we'd want more than 3 "base" iterations, as I would expect scheduling events to occur more frequently than e.g. SMI (and with a higher probability of multiple ones occurring in close succession).
Jan
Quoted 9 lines · Jan Beulich
Quoted 8 lines · Jan Beulich
Calibration logic assumes that the platform timer (HPET or ACPI PM timer) and the TSC are read at about the same time. This assumption may not hold when a long latency event (e.g. SMI or NMI) occurs between the two reads. Reduce the risk of reading uncorrelated values by doing at least four pairs of reads, using the tuple where the delta between the enclosing TSC reads was smallest. From the fourth iteration onwards bail if the new TSC delta isn't better (smaller) than the best earlier one.
Quoted 7 lines
Quoted 1 line
Signed-off-by Jan Beulich <[email protected]>When running virtualized, scheduling in the host would also constitute long latency events. I wonder whether, to compensate for that, we'd want more than 3 "base" iterations, as I would expect scheduling events to occur more frequently than e.g. SMI (and with a higher probability of multiple ones occurring in close succession).
Should Xen be continually or periodically recalibrating? Rather than trying to get it perfect at the start of day?
You may also be able to find inspiration from the design or implementation of the Precision Time Protocol which has to similarly filter out outliers due to transmission delays.
David
Quoted 7 lines · Jan Beulich
Calibration logic assumes that the platform timer (HPET or ACPI PM timer) and the TSC are read at about the same time. This assumption may not hold when a long latency event (e.g. SMI or NMI) occurs between the two reads. Reduce the risk of reading uncorrelated values by doing at least four pairs of reads, using the tuple where the delta between the enclosing TSC reads was smallest. From the fourth iteration onwards bail if the new TSC delta isn't better (smaller) than the best earlier one.
Do you have some measurements as to whether this makes the frequency detection any more accurate?
Quoted 4 lines
Signed-off-by Jan Beulich <[email protected]>---
Obviously (I think) instead of having both read_{hpet,pmtmr}_and_tsc() the calibration logic could be folded between HPET and PMTMR, at the
As an intermediate solution you could have a read_counter_and_tsc I would think?
Quoted 5 lines
expense of a couple more indirect calls (which may not be that much of a problem as this is all boot-time only). Really such folding would have been possible already before, just that the amount of duplicate code hasn't been this large so far. IOW if so desired, then perhaps the folding should be a separate prereq patch.
You could even pass a platform_timesource as a parameter to that generic read counter and TSC helper.
Quoted 18 lines
xen/arch/x86/time.c +12
-0@@ -392,9 +392,36 @@ static u64 read_hpet_count(void)return hpet_read32 (HPET_COUNTER ); } +static uint32_t __init read_hpet_and_tsc (uint64_t *tsc) +{ +uint64_t tsc_prev = *tsc =rdtsc_ordered (), tsc_min = ~0 ; +uint32_t best = best; +unsigned int i; + +for ( i =0 ; ; ++i ) + { +uint32_t hpet =hpet_read32 (HPET_COUNTER ); +uint64_t tsc_cur =rdtsc_ordered (); +uint64_t tsc_delta = tsc_cur - tsc_prev; +
xen/arch/x86/time.c static u64 read_hpet_count(void) · line 416
Quoted 10 lines
xen/arch/x86/time.c +10
-0+if ( tsc_delta < tsc_min ) + { + tsc_min = tsc_delta; + *tsc = tsc_cur; + best = hpet; + } +else if ( i >2 ) +break ; + + tsc_prev = tsc_cur;
Would it be better to set tsc_prev to the current TSC value here in order to minimize the window you are measuring? Or else tsc_delta will also account for the time in the loop code, and there's more likeliness from being interrupted?
I guess being interrupted four times so that all loops are bad is very unlikely.
Since this loop could in theory run multiple times, do we need to check that the counter doesn't overflow? Or else the elapsed counter value would be miscalculated.
Thanks, Roger.
Quoted 14 lines · David Vrabel
Quoted 11 lines · Jan Beulich
Quoted 9 lines · Jan Beulich
Calibration logic assumes that the platform timer (HPET or ACPI PM timer) and the TSC are read at about the same time. This assumption may not hold when a long latency event (e.g. SMI or NMI) occurs between the two reads. Reduce the risk of reading uncorrelated values by doing at least four pairs of reads, using the tuple where the delta between the enclosing TSC reads was smallest. From the fourth iteration onwards bail if the new TSC delta isn't better (smaller) than the best earlier one.
Signed-off-by Jan Beulich <[email protected]>
Quoted 8 lines
Quoted 5 lines
When running virtualized, scheduling in the host would also constitute long latency events. I wonder whether, to compensate for that, we'd want more than 3 "base" iterations, as I would expect scheduling events to occur more frequently than e.g. SMI (and with a higher probability of multiple ones occurring in close succession).
Should Xen be continually or periodically recalibrating? Rather than trying to get it perfect at the start of day?
I wouldn't call dealing with bad samples "getting it perfect". IOW I think recalibrating later may be an option, but independent of what I'm doing here.
Quoted 3 lines
You may also be able to find inspiration from the design or implementation of the Precision Time Protocol which has to similarly filter out outliers due to transmission delays.
Thanks for the pointer.
Jan
Quoted 11 lines · Roger Pau Monné
Quoted 7 lines · Jan Beulich
Calibration logic assumes that the platform timer (HPET or ACPI PM timer) and the TSC are read at about the same time. This assumption may not hold when a long latency event (e.g. SMI or NMI) occurs between the two reads. Reduce the risk of reading uncorrelated values by doing at least four pairs of reads, using the tuple where the delta between the enclosing TSC reads was smallest. From the fourth iteration onwards bail if the new TSC delta isn't better (smaller) than the best earlier one.
Do you have some measurements as to whether this makes the frequency detection any more accurate?
In the normal case (no SMI or alike) I haven't observed any further improvement on top of the earlier patch.
Quoted 7 lines
Quoted 4 lines
Signed-off-by Jan Beulich <[email protected]>---
Obviously (I think) instead of having both read_{hpet,pmtmr}_and_tsc() the calibration logic could be folded between HPET and PMTMR, at theAs an intermediate solution you could have a
read_counter_and_tscI would think?
Not sure in which way you view this as "intermediate".
Quoted 8 lines
Quoted 5 lines
expense of a couple more indirect calls (which may not be that much of a problem as this is all boot-time only). Really such folding would have been possible already before, just that the amount of duplicate code hasn't been this large so far. IOW if so desired, then perhaps the folding should be a separate prereq patch.
You could even pass a
platform_timesourceas a parameter to that generic read counter and TSC helper.
This was the plan, yes, in case I was asked to follow that route (or if I decided myself that I'd prefer that significantly over the redundancy).
Quoted 25 lines
Quoted 25 lines
xen/arch/x86/time.c +19
-0@@ -392,9 +392,36 @@ static u64 read_hpet_count(void)return hpet_read32 (HPET_COUNTER ); } +static uint32_t __init read_hpet_and_tsc (uint64_t *tsc) +{ +uint64_t tsc_prev = *tsc =rdtsc_ordered (), tsc_min = ~0 ; +uint32_t best = best; +unsigned int i; + +for ( i =0 ; ; ++i ) + { +uint32_t hpet =hpet_read32 (HPET_COUNTER ); +uint64_t tsc_cur =rdtsc_ordered (); +uint64_t tsc_delta = tsc_cur - tsc_prev; + +if ( tsc_delta < tsc_min ) + { + tsc_min = tsc_delta; + *tsc = tsc_cur; + best = hpet; + } +else if ( i >2 )
Quoted 8 lines
xen/arch/x86/time.c static u64 read_hpet_count(void) · line 416
Quoted 3 lines
xen/arch/x86/time.c +3
-0+break ; + + tsc_prev = tsc_cur;Would it be better to set
tsc_prevto the current TSC value here in order to minimize the window you are measuring? Or elsetsc_deltawill also account for the time in the loop code, and there's more likeliness from being interrupted?
I did consider this (or some variant thereof), but did for the moment conclude that it wouldn't make enough of a difference. If you think it would be meaningfully better that way, I'll switch.
Both here and for the aspect above, please express you preference (i.e. not in the form of a question).
Quoted 6 lines
I guess being interrupted four times so that all loops are bad is very unlikely.
Since this loop could in theory run multiple times, do we need to check that the counter doesn't overflow? Or else the elapsed counter value would be miscalculated.
I don't think I see any issue with overflow here. It's the callers who need to care about that. And I don't think this function will run for long enough such that a counter would not only wrap, but also reach its initial count again.
Jan
Quoted 21 lines · Jan Beulich
Quoted 11 lines · Roger Pau Monné
Quoted 7 lines · Jan Beulich
Calibration logic assumes that the platform timer (HPET or ACPI PM timer) and the TSC are read at about the same time. This assumption may not hold when a long latency event (e.g. SMI or NMI) occurs between the two reads. Reduce the risk of reading uncorrelated values by doing at least four pairs of reads, using the tuple where the delta between the enclosing TSC reads was smallest. From the fourth iteration onwards bail if the new TSC delta isn't better (smaller) than the best earlier one.
Do you have some measurements as to whether this makes the frequency detection any more accurate?
In the normal case (no SMI or alike) I haven't observed any further improvement on top of the earlier patch.
Quoted 5 lines
Quoted 4 lines
Signed-off-by Jan Beulich <[email protected]>---
Obviously (I think) instead of having both read_{hpet,pmtmr}_and_tsc() the calibration logic could be folded between HPET and PMTMR, at the
Quoted 4 lines
Quoted 2 lines
As an intermediate solution you could have a
read_counter_and_tscI would think?Not sure in which way you view this as "intermediate".
As in not unifying both calibration logic into a single function, but rather just use a generic function to read the counter and TSC.
With your original remark I assumed that you wanted to unify all the calibration code in init_hpet and init_pmtimer into a generic function, but maybe I've misunderstood.
Quoted 6 lines
Quoted 6 lines
Quoted 5 lines
expense of a couple more indirect calls (which may not be that much of a problem as this is all boot-time only). Really such folding would have been possible already before, just that the amount of duplicate code hasn't been this large so far. IOW if so desired, then perhaps the folding should be a separate prereq patch.
Quoted 6 lines
Quoted 2 lines
You could even pass a
platform_timesourceas a parameter to that generic read counter and TSC helper.This was the plan, yes, in case I was asked to follow that route (or if I decided myself that I'd prefer that significantly over the redundancy).
I think having a generic read_counter_and_tsc would be better than having read_{hpet,pmtmr}_and_tsc.
Quoted 35 lines
Quoted 26 lines
Quoted 26 lines
xen/arch/x86/time.c +19
-0@@ -392,9 +392,36 @@ static u64 read_hpet_count(void)return hpet_read32 (HPET_COUNTER ); } +static uint32_t __init read_hpet_and_tsc (uint64_t *tsc) +{ +uint64_t tsc_prev = *tsc =rdtsc_ordered (), tsc_min = ~0 ; +uint32_t best = best; +unsigned int i; + +for ( i =0 ; ; ++i ) + { +uint32_t hpet =hpet_read32 (HPET_COUNTER ); +uint64_t tsc_cur =rdtsc_ordered (); +uint64_t tsc_delta = tsc_cur - tsc_prev; + +if ( tsc_delta < tsc_min ) + { + tsc_min = tsc_delta; + *tsc = tsc_cur; + best = hpet; + } +else if ( i >2 )Quoted 8 lines
xen/arch/x86/time.c static u64 read_hpet_count(void) · line 416
Quoted 3 lines
xen/arch/x86/time.c +3
-0+break ; + + tsc_prev = tsc_cur;Would it be better to set
tsc_prevto the current TSC value here in order to minimize the window you are measuring? Or elsetsc_deltawill also account for the time in the loop code, and there's more likeliness from being interrupted?
Quoted 6 lines
I did consider this (or some variant thereof), but did for the moment conclude that it wouldn't make enough of a difference. If you think it would be meaningfully better that way, I'll switch.
Both here and for the aspect above, please express you preference (i.e. not in the form of a question).
Let's leave it as-is (just one TSC read per loop iteration).
Quoted 11 lines
Quoted 6 lines
I guess being interrupted four times so that all loops are bad is very unlikely.
Since this loop could in theory run multiple times, do we need to check that the counter doesn't overflow? Or else the elapsed counter value would be miscalculated.
I don't think I see any issue with overflow here. It's the callers who need to care about that. And I don't think this function will run for long enough such that a counter would not only wrap, but also reach its initial count again.
Right, I haven't expressed myself correctly. It's not overflowing the issue, but rather wrapping to the start count value. Limiting the iterations to some fixed value (10?) in order to remove that possibility completely would be OK for me.
Thanks, Roger.
Quoted 25 lines · Roger Pau Monné
Quoted 24 lines · Jan Beulich
Quoted 11 lines · Roger Pau Monné
Quoted 7 lines · Jan Beulich
Calibration logic assumes that the platform timer (HPET or ACPI PM timer) and the TSC are read at about the same time. This assumption may not hold when a long latency event (e.g. SMI or NMI) occurs between the two reads. Reduce the risk of reading uncorrelated values by doing at least four pairs of reads, using the tuple where the delta between the enclosing TSC reads was smallest. From the fourth iteration onwards bail if the new TSC delta isn't better (smaller) than the best earlier one.
Do you have some measurements as to whether this makes the frequency detection any more accurate?
In the normal case (no SMI or alike) I haven't observed any further improvement on top of the earlier patch.
Quoted 7 lines
Quoted 4 lines
Signed-off-by Jan Beulich <[email protected]>---
Obviously (I think) instead of having both read_{hpet,pmtmr}_and_tsc() the calibration logic could be folded between HPET and PMTMR, at theAs an intermediate solution you could have a
read_counter_and_tscI would think?
Quoted 8 lines
Quoted 1 line
Not sure in which way you view this as "intermediate".
As in not unifying both calibration logic into a single function, but rather just use a generic function to read the counter and TSC.
With your original remark I assumed that you wanted to unify all the calibration code in
init_hpetandinit_pmtimerinto a generic function, but maybe I've misunderstood.
Oh, I see. I have to admit that I see little value (at this point) to break out just the pair-read logic. While I did say we have similar issues elsewhere, my initial analysis has left me with the impression that those other cases are sufficiently different for such a helper to be of no use there.
Quoted 72 lines
Quoted 6 lines
Quoted 6 lines
Quoted 5 lines
expense of a couple more indirect calls (which may not be that much of a problem as this is all boot-time only). Really such folding would have been possible already before, just that the amount of duplicate code hasn't been this large so far. IOW if so desired, then perhaps the folding should be a separate prereq patch.
Quoted 6 lines
Quoted 2 lines
You could even pass a
platform_timesourceas a parameter to that generic read counter and TSC helper.This was the plan, yes, in case I was asked to follow that route (or if I decided myself that I'd prefer that significantly over the redundancy).
I think having a generic
read_counter_and_tscwould be better than having read_{hpet,pmtmr}_and_tsc.Quoted 35 lines
Quoted 26 lines
Quoted 26 lines
xen/arch/x86/time.c +19
-0@@ -392,9 +392,36 @@ static u64 read_hpet_count(void)return hpet_read32 (HPET_COUNTER ); } +static uint32_t __init read_hpet_and_tsc (uint64_t *tsc) +{ +uint64_t tsc_prev = *tsc =rdtsc_ordered (), tsc_min = ~0 ; +uint32_t best = best; +unsigned int i; + +for ( i =0 ; ; ++i ) + { +uint32_t hpet =hpet_read32 (HPET_COUNTER ); +uint64_t tsc_cur =rdtsc_ordered (); +uint64_t tsc_delta = tsc_cur - tsc_prev; + +if ( tsc_delta < tsc_min ) + { + tsc_min = tsc_delta; + *tsc = tsc_cur; + best = hpet; + } +else if ( i >2 )Quoted 8 lines
xen/arch/x86/time.c static u64 read_hpet_count(void) · line 416
Quoted 3 lines
xen/arch/x86/time.c +3
-0+break ; + + tsc_prev = tsc_cur;Would it be better to set
tsc_prevto the current TSC value here in order to minimize the window you are measuring? Or elsetsc_deltawill also account for the time in the loop code, and there's more likeliness from being interrupted?Quoted 6 lines
I did consider this (or some variant thereof), but did for the moment conclude that it wouldn't make enough of a difference. If you think it would be meaningfully better that way, I'll switch.
Both here and for the aspect above, please express you preference (i.e. not in the form of a question).
Let's leave it as-is (just one TSC read per loop iteration).
Quoted 11 lines
Quoted 6 lines
I guess being interrupted four times so that all loops are bad is very unlikely.
Since this loop could in theory run multiple times, do we need to check that the counter doesn't overflow? Or else the elapsed counter value would be miscalculated.
I don't think I see any issue with overflow here. It's the callers who need to care about that. And I don't think this function will run for long enough such that a counter would not only wrap, but also reach its initial count again.
Quoted 4 lines
Right, I haven't expressed myself correctly. It's not overflowing the issue, but rather wrapping to the start count value. Limiting the iterations to some fixed value (10?) in order to remove that possibility completely would be OK for me.
Hmm, I was in fact hoping (and trying) to get away without any arbitrarily chosen numbers. The loop cannot be infinite in any event ... Please let me know how strong you feel about putting in place such an arbitrary limit.
Jan
Quoted 113 lines · Jan Beulich
Quoted 25 lines · Roger Pau Monné
Quoted 24 lines · Jan Beulich
Quoted 11 lines · Roger Pau Monné
Quoted 7 lines · Jan Beulich
Calibration logic assumes that the platform timer (HPET or ACPI PM timer) and the TSC are read at about the same time. This assumption may not hold when a long latency event (e.g. SMI or NMI) occurs between the two reads. Reduce the risk of reading uncorrelated values by doing at least four pairs of reads, using the tuple where the delta between the enclosing TSC reads was smallest. From the fourth iteration onwards bail if the new TSC delta isn't better (smaller) than the best earlier one.
Do you have some measurements as to whether this makes the frequency detection any more accurate?
In the normal case (no SMI or alike) I haven't observed any further improvement on top of the earlier patch.
Quoted 7 lines
Quoted 4 lines
Signed-off-by Jan Beulich <[email protected]>---
Obviously (I think) instead of having both read_{hpet,pmtmr}_and_tsc() the calibration logic could be folded between HPET and PMTMR, at theAs an intermediate solution you could have a
read_counter_and_tscI would think?Quoted 8 lines
Quoted 1 line
Not sure in which way you view this as "intermediate".
As in not unifying both calibration logic into a single function, but rather just use a generic function to read the counter and TSC.
With your original remark I assumed that you wanted to unify all the calibration code in
init_hpetandinit_pmtimerinto a generic function, but maybe I've misunderstood.Oh, I see. I have to admit that I see little value (at this point) to break out just the pair-read logic. While I did say we have similar issues elsewhere, my initial analysis has left me with the impression that those other cases are sufficiently different for such a helper to be of no use there.
Quoted 72 lines
Quoted 6 lines
Quoted 6 lines
Quoted 5 lines
expense of a couple more indirect calls (which may not be that much of a problem as this is all boot-time only). Really such folding would have been possible already before, just that the amount of duplicate code hasn't been this large so far. IOW if so desired, then perhaps the folding should be a separate prereq patch.
Quoted 6 lines
Quoted 2 lines
You could even pass a
platform_timesourceas a parameter to that generic read counter and TSC helper.This was the plan, yes, in case I was asked to follow that route (or if I decided myself that I'd prefer that significantly over the redundancy).
I think having a generic
read_counter_and_tscwould be better than having read_{hpet,pmtmr}_and_tsc.Quoted 35 lines
Quoted 26 lines
Quoted 26 lines
xen/arch/x86/time.c +19
-0@@ -392,9 +392,36 @@ static u64 read_hpet_count(void)return hpet_read32 (HPET_COUNTER ); } +static uint32_t __init read_hpet_and_tsc (uint64_t *tsc) +{ +uint64_t tsc_prev = *tsc =rdtsc_ordered (), tsc_min = ~0 ; +uint32_t best = best; +unsigned int i; + +for ( i =0 ; ; ++i ) + { +uint32_t hpet =hpet_read32 (HPET_COUNTER ); +uint64_t tsc_cur =rdtsc_ordered (); +uint64_t tsc_delta = tsc_cur - tsc_prev; + +if ( tsc_delta < tsc_min ) + { + tsc_min = tsc_delta; + *tsc = tsc_cur; + best = hpet; + } +else if ( i >2 )Quoted 8 lines
xen/arch/x86/time.c static u64 read_hpet_count(void) · line 416
Quoted 3 lines
xen/arch/x86/time.c +3
-0+break ; + + tsc_prev = tsc_cur;Would it be better to set
tsc_prevto the current TSC value here in order to minimize the window you are measuring? Or elsetsc_deltawill also account for the time in the loop code, and there's more likeliness from being interrupted?Quoted 6 lines
I did consider this (or some variant thereof), but did for the moment conclude that it wouldn't make enough of a difference. If you think it would be meaningfully better that way, I'll switch.
Both here and for the aspect above, please express you preference (i.e. not in the form of a question).
Let's leave it as-is (just one TSC read per loop iteration).
Quoted 11 lines
Quoted 6 lines
I guess being interrupted four times so that all loops are bad is very unlikely.
Since this loop could in theory run multiple times, do we need to check that the counter doesn't overflow? Or else the elapsed counter value would be miscalculated.
I don't think I see any issue with overflow here. It's the callers who need to care about that. And I don't think this function will run for long enough such that a counter would not only wrap, but also reach its initial count again.
Quoted 8 lines
Quoted 4 lines
Right, I haven't expressed myself correctly. It's not overflowing the issue, but rather wrapping to the start count value. Limiting the iterations to some fixed value (10?) in order to remove that possibility completely would be OK for me.
Hmm, I was in fact hoping (and trying) to get away without any arbitrarily chosen numbers. The loop cannot be infinite in any event ... Please let me know how strong you feel about putting in place such an arbitrary limit.
It was mostly for safety reasons, I wouldn't expect that loop to need more than 4 iterations really (which is also an arbitrary chosen number). Let's leave it without any limit then for the time being.
Roger.
Quoted 51 lines · Roger Pau Monné
Quoted 50 lines · Jan Beulich
Quoted 25 lines · Roger Pau Monné
Quoted 24 lines · Jan Beulich
Quoted 11 lines · Roger Pau Monné
Quoted 7 lines · Jan Beulich
Calibration logic assumes that the platform timer (HPET or ACPI PM timer) and the TSC are read at about the same time. This assumption may not hold when a long latency event (e.g. SMI or NMI) occurs between the two reads. Reduce the risk of reading uncorrelated values by doing at least four pairs of reads, using the tuple where the delta between the enclosing TSC reads was smallest. From the fourth iteration onwards bail if the new TSC delta isn't better (smaller) than the best earlier one.
Do you have some measurements as to whether this makes the frequency detection any more accurate?
In the normal case (no SMI or alike) I haven't observed any further improvement on top of the earlier patch.
Quoted 7 lines
Quoted 4 lines
Signed-off-by Jan Beulich <[email protected]>---
Obviously (I think) instead of having both read_{hpet,pmtmr}_and_tsc() the calibration logic could be folded between HPET and PMTMR, at theAs an intermediate solution you could have a
read_counter_and_tscI would think?Quoted 8 lines
Quoted 1 line
Not sure in which way you view this as "intermediate".
As in not unifying both calibration logic into a single function, but rather just use a generic function to read the counter and TSC.
With your original remark I assumed that you wanted to unify all the calibration code in
init_hpetandinit_pmtimerinto a generic function, but maybe I've misunderstood.Oh, I see. I have to admit that I see little value (at this point) to break out just the pair-read logic. While I did say we have similar issues elsewhere, my initial analysis has left me with the impression that those other cases are sufficiently different for such a helper to be of no use there.
Quoted 9 lines
Quoted 9 lines
Quoted 8 lines
Quoted 5 lines
expense of a couple more indirect calls (which may not be that much of a problem as this is all boot-time only). Really such folding would have been possible already before, just that the amount of duplicate code hasn't been this large so far. IOW if so desired, then perhaps the folding should be a separate prereq patch.
You could even pass a
platform_timesourceas a parameter to that generic read counter and TSC helper.
Quoted 6 lines
Quoted 6 lines
Quoted 6 lines
Quoted 3 lines
This was the plan, yes, in case I was asked to follow that route (or if I decided myself that I'd prefer that significantly over the redundancy).
I think having a generic
read_counter_and_tscwould be better than having read_{hpet,pmtmr}_and_tsc.
Btw, I think I will want to break out the full calibration logic, to then further generalize it to make suitable for LAPIC timer calibration (then no longer against the PIT, but against the earlier chosen platform timer).
Quoted 60 lines
Quoted 60 lines
Quoted 59 lines
Quoted 34 lines
Quoted 25 lines
Quoted 25 lines
xen/arch/x86/time.c +19
-0@@ -392,9 +392,36 @@ static u64 read_hpet_count(void)return hpet_read32 (HPET_COUNTER ); } +static uint32_t __init read_hpet_and_tsc (uint64_t *tsc) +{ +uint64_t tsc_prev = *tsc =rdtsc_ordered (), tsc_min = ~0 ; +uint32_t best = best; +unsigned int i; + +for ( i =0 ; ; ++i ) + { +uint32_t hpet =hpet_read32 (HPET_COUNTER ); +uint64_t tsc_cur =rdtsc_ordered (); +uint64_t tsc_delta = tsc_cur - tsc_prev; + +if ( tsc_delta < tsc_min ) + { + tsc_min = tsc_delta; + *tsc = tsc_cur; + best = hpet; + } +else if ( i >2 )Quoted 8 lines
xen/arch/x86/time.c static u64 read_hpet_count(void) · line 416
Quoted 3 lines
xen/arch/x86/time.c +3
-0+break ; + + tsc_prev = tsc_cur;Would it be better to set
tsc_prevto the current TSC value here in order to minimize the window you are measuring? Or elsetsc_deltawill also account for the time in the loop code, and there's more likeliness from being interrupted?Quoted 6 lines
I did consider this (or some variant thereof), but did for the moment conclude that it wouldn't make enough of a difference. If you think it would be meaningfully better that way, I'll switch.
Both here and for the aspect above, please express you preference (i.e. not in the form of a question).
Let's leave it as-is (just one TSC read per loop iteration).
Quoted 11 lines
Quoted 6 lines
I guess being interrupted four times so that all loops are bad is very unlikely.
Since this loop could in theory run multiple times, do we need to check that the counter doesn't overflow? Or else the elapsed counter value would be miscalculated.
I don't think I see any issue with overflow here. It's the callers who need to care about that. And I don't think this function will run for long enough such that a counter would not only wrap, but also reach its initial count again.
Right, I haven't expressed myself correctly. It's not overflowing the issue, but rather wrapping to the start count value. Limiting the iterations to some fixed value (10?) in order to remove that possibility completely would be OK for me.
Quoted 7 lines
Quoted 3 lines
Hmm, I was in fact hoping (and trying) to get away without any arbitrarily chosen numbers. The loop cannot be infinite in any event ... Please let me know how strong you feel about putting in place such an arbitrary limit.
It was mostly for safety reasons, I wouldn't expect that loop to need more than 4 iterations really (which is also an arbitrary chosen number).
Fair point - I should have said "without further arbitrarily chosen numbers".
Quoted 1 line
Let's leave it without any limit then for the time being.
Thanks.
Jan