Skip to contentSkip to conversation

IPMI Show DIMM SPD Feature

DISCUSSION Yonghui YH21 Liu 2 participants 2 messages Dec 2, 2019 – Dec 3, 2019

lore
Share & tools
lore
#0 lore raw

Hi all,
Could you help double confirm whether BMC can show DIMM SPD information by IPMI interface in current openBMC design? If yes, could you help provide some guidance on implementing the feature.

Thank your great support.

#1 lore raw
Quoted 8 lines · 02.12.2019 14:49, Yonghui YH21 Liu wrote:

Hi all,

       Could you help double confirm whether BMC can show DIMM SPD information by IPMI interface in current openBMC design?

       If yes, could you help provide some guidance on implementing the feature.

If you're referring to product info like part number, vendor, etc., then yes, OpenBMC can show it.

Your host system must be sending SPD info into BMC as IPMI FRU. OpenPOWER Firmware does that. Can't say for other types of hosts.

You must have a proper configuration for phosphor-ipmi-fru. Take a look at how this is done for YADRO VESNIN:

https://github.com/openbmc/openbmc/blob/master/meta-yadro/meta-vesnin/recipes-phosphor/ipmi/phosphor-ipmi-fru_%25.bbappend

https://github.com/openbmc/openbmc/blob/master/meta-yadro/meta-vesnin/recipes-phosphor/configuration/vesnin-yaml-config.bb

https://github.com/openbmc/openbmc/blob/master/meta-yadro/meta-vesnin/recipes-phosphor/configuration/vesnin-yaml-config/vesnin-ipmi-fru.yaml

The first number there is the FRU ID used by the host in IPMI Write FRU Data command:

Quoted 2 lines

  22:
         /system/chassis/motherboard/dimm8:

With best regards,
Alexander Amelkin