CD-ROM size not updated when switching CD-ROM images.

DISCUSSION Alex Davis 3 participants 6 messages Oct 19, 2010 – Oct 30, 2010 KVM

lore
Share & tools
lore

Alex Davis

author
#0 lore raw

Steps to reproduce:
) Download the first two Slackware-13.1 32-bit CD-ROM ISO images. ) Start KVM with the following command

   qemu-system-x86_64 -m 1024M \
     -cdrom < full path of 1st install disk > \
     -boot d

) Hit return when prompted for extra boot parameters.
) Hit return when asked to select a keyboard map.
) Hit return at the login prompt.
) cat /sys/block/sr0/size: this should return 1209360.
) Press Alt-Ctrl-2 to access the monitor
) eject ide1-cd0
) change ide1-cd0 < full path name of 2nd install disk >
) Press Alt-Ctrl-1 to return to the guest.
) dd if=/dev/sr0 of=/dev/null bs=512 skip=1209360 count=3
this should return
3+0 records in
3+0 records out.
instead it returns 0+0....
) cat /sys/block/sr0/size: this still returns 1209360; it should return 1376736.

Oddly, when "mount /dev/sr0 ...." is executed in the guest, ls of the mounted directory shows the correct contents for the 2nd CD.

KVM version is kvm-qemu-0.13.0

Host CPU model name : Intel(R) Core(TM)2 Duo CPU E8600 @ 3.33GHz
Host kernel is 2.6.32.12 Host arch is x86_64

Guest is Slackware 13.1 32-bit Guest kernel version is 2.6.33.4

Start command:
qemu-system-x86_64 -m 1024M \
-cdrom /spare2/slackware-13.1-install-d1.iso \
-boot d

Not affected by -no-kvm-irqchip Not affected by -no-kvm-pit Not affected by -no-kvm

I can test patches.

Built with:
bash-3.2$ ./configure --prefix=/usr/kvm-qemu-0.13.0 --extra-ldflags="-L/usr/X11R7.4/lib"

Install prefix    /usr/kvm-qemu-0.13.0
BIOS directory    /usr/kvm-qemu-0.13.0/share/qemu
binary directory  /usr/kvm-qemu-0.13.0/bin
config directory  /usr/kvm-qemu-0.13.0/etc
Manual directory  /usr/kvm-qemu-0.13.0/share/man
ELF interp prefix /usr/gnemul/qemu-%M
Source path       /sources/qemu-kvm-0.13.0
C compiler        gcc
Host C compiler   gcc
CFLAGS            -O2 -g
QEMU_CFLAGS       -m64 -fstack-protector-all -Wold-style-definition -I. -I$(SRC_PATH) -D_FORTIFY_SOURCE=2 -D_GNU_SOURCE -D_FILE_OFFSET_BITS=64 -D_LARGEFILE_SOURCE -Wstrict-prototypes -Wredundant-decls -Wall -Wundef -Wendif-labels -Wwrite-strings -Wmissing-prototypes -fno-strict-aliasing
LDFLAGS           -Wl,--warn-common -m64 -g -L/usr/X11R7.4/lib
make              make
install           install
host CPU          x86_64
host big endian   no
target list       x86_64-softmmu
tcg debug enabled no
Mon debug enabled no
gprof enabled     no
sparse enabled    no
strip binaries    yes
profiler          no
static build      no
-Werror enabled   no
SDL support       yes
curses support    yes
curl support      yes
check support     no
mingw32 support   no
Audio drivers     oss
Extra audio cards ac97 es1370 sb16
Block whitelist
Mixer emulation   no
VNC TLS support   no
VNC SASL support  yes
VNC JPEG support  yes
VNC PNG support   yes
VNC thread        no
xen support       no
CPU emulation     yes
brlapi support    no
bluez  support    no
Documentation     yes
NPTL support      yes
GUEST_BASE        yes
PIE user targets  no
vde support       no
IO thread         no
Linux AIO support no
ATTR/XATTR support yes
Install blobs     yes
KVM support       yes
KVM PIT support   yes
KVM device assig. yes
fdt support       no
preadv support    no
fdatasync         yes
uuid support      yes

vhost-net support yes
I code, therefore I am

#1 lore raw
Quoted 21 lines · Alex Davis

Steps to reproduce:
) Download the first two Slackware-13.1 32-bit CD-ROM ISO images.
) Start KVM with the following command
  qemu-system-x86_64 -m 1024M \
    -cdrom < full path of 1st install disk > \
    -boot d
) Hit return when prompted for extra boot parameters.
) Hit return when asked to select a keyboard map.
) Hit return at the login prompt.
) cat /sys/block/sr0/size: this should return 1209360.
) Press Alt-Ctrl-2 to access the monitor
) eject ide1-cd0
) change ide1-cd0 < full path name of 2nd install disk >
) Press Alt-Ctrl-1 to return to the guest.
) dd if=/dev/sr0 of=/dev/null bs=512 skip=1209360 count=3
 this should return
  3+0 records in
  3+0 records out.
 instead it returns 0+0....
) cat /sys/block/sr0/size: this still returns 1209360; it should return 1376736.

Quoted 1 line

Oddly, when "mount /dev/sr0 ...." is  executed in the guest, ls of the mounted directory shows the correct contents for the 2nd CD.

After changing the CD-ROM, does running "blockdev --rereadpt /dev/sr0" update the size as expected?

You ejected the CD-ROM on the QEMU side, the guest doesn't necessarily know about the medium change. What happens when you use "eject /dev/sr0" inside the guest instead?

I don't know how CD-ROM media change works on real hardware, but that is the behavior that QEMU should be following.

Stefan

author
#2 lore raw

I code, therefore I am

Quoted 35 lines · Stefan Hajnoczi

From: Stefan Hajnoczi <[email protected]>
Subject: Re: CD-ROM size not updated when switching CD-ROM images.
To: "Alex Davis" <[email protected]>
Cc: [email protected]
Date: Tuesday, October 19, 2010, 4:31 AM

Quoted 2 lines · Alex Davis

Steps to reproduce:
) Download the first two Slackware-13.1 32-bit CD-ROM

ISO images.

Quoted 3 lines

) Start KVM with the following command
  qemu-system-x86_64 -m 1024M \
    -cdrom < full path of 1st install disk >

\

Quoted 5 lines

    -boot d
) Hit return when prompted for extra boot parameters. ) Hit return when asked to select a keyboard map. ) Hit return at the login prompt.
) cat /sys/block/sr0/size: this should return

1209360.

Quoted 3 lines

) Press Alt-Ctrl-2 to access the monitor
) eject ide1-cd0
) change ide1-cd0 < full path name of 2nd install

disk >

Quoted 2 lines

) Press Alt-Ctrl-1 to return to the guest.
) dd if=/dev/sr0 of=/dev/null bs=512 skip=1209360

count=3

Quoted 5 lines

 this should return
  3+0 records in
  3+0 records out.
 instead it returns 0+0....
) cat /sys/block/sr0/size: this still returns 1209360;

it should return 1376736.

Quoted 1 line
Quoted 7 lines
Quoted 1 line

Oddly, when "mount /dev/sr0 ...." is  executed in the

guest, ls of the mounted directory shows the correct contents for the 2nd CD.

After changing the CD-ROM, does running "blockdev
--rereadpt /dev/sr0"
update the size as expected?

The install CD does not have the blockdev command.

Quoted 5 lines

You ejected the CD-ROM on the QEMU side, the guest doesn't necessarily
know about the medium change.  What happens when you use "eject
/dev/sr0" inside the guest instead?

I get a 'no medium found' error from the 'dd..' command. After going into the the monitor, ejecting and reloading the disk, I still get the size of the first disk in the guest.

Quoted 6 lines

I don't know how CD-ROM media change works on real hardware, but that
is the behavior that QEMU should be following.

Stefan

#3 lore raw
Quoted 8 lines · Alex Davis
Quoted 5 lines

You ejected the CD-ROM on the QEMU side, the guest doesn't necessarily
know about the medium change. What happens when you use "eject
/dev/sr0" inside the guest instead?

I get a 'no medium found' error from the 'dd..' command. After going into the the monitor, ejecting and reloading the disk, I still get the size of the first disk in the guest.

As I recall the old data is coming from the host page cache; it is not seeing the media change. Try dropping the cache in the host on a media change (echo 3 > /proc/sys/vm/drop_caches) or modify qemu to close and reopen the cdrom device.

David

Quoted 14 lines
Quoted 6 lines

I don't know how CD-ROM media change works on real hardware, but that
is the behavior that QEMU should be following.

Stefan

--
To unsubscribe from this list: send the line "unsubscribe kvm" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

author
#4 lore raw

I code, therefore I am

Quoted 19 lines · David Ahern

From: David Ahern <[email protected]>
Subject: Re: CD-ROM size not updated when switching CD-ROM images.
To: "Alex Davis" <[email protected]>
Cc: "Stefan Hajnoczi" <[email protected]>, [email protected]
Date: Wednesday, October 20, 2010, 12:44 PM

Quoted 1 line · Alex Davis
Quoted 1 line

You ejected the CD-ROM on the QEMU side, the guest

doesn't

Quoted 2 lines
Quoted 2 lines

necessarily
know about the medium change.  What happens

when you

Quoted 3 lines
Quoted 2 lines

use "eject
/dev/sr0" inside the guest instead?

I get a 'no medium found' error from the 'dd..'

command. After

Quoted 1 line

going into the the monitor, ejecting and reloading the

Quoted 8 lines

disk,

Quoted 1 line

I still get the size of the first disk in the guest.

As I recall the old data is coming from the host page cache; it is not
seeing the media change. Try dropping the cache in the host on a media
change (echo 3 > /proc/sys/vm/drop_caches)

This had no effect.

Quoted 3 lines

or modify
qemu to close and
reopen the cdrom device.

QEMU already does this.

Quoted 20 lines

David

Quoted 2 lines
Quoted 2 lines

I don't know how CD-ROM media change works on

real

Quoted 9 lines
Quoted 4 lines

hardware, but that
is the behavior that QEMU should be following.

Stefan


--
To unsubscribe from this list: send the line

"unsubscribe kvm" in

Quoted 3 lines

the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html

author
#5 lore raw
In reply to David Ahern
Quoted 30 lines · David Ahern

From: David Ahern <[email protected]>
Subject: Re: CD-ROM size not updated when switching CD-ROM images.
To: "Alex Davis" <[email protected]>
Cc: "Stefan Hajnoczi" <[email protected]>, [email protected]
Date: Wednesday, October 20, 2010, 12:44 PM

Quoted 1 line · Alex Davis
Quoted 1 line

You ejected the CD-ROM on the QEMU side, the guest

doesn't

Quoted 2 lines
Quoted 2 lines

necessarily
know about the medium change. What happens

when you

Quoted 3 lines
Quoted 2 lines

use "eject
/dev/sr0" inside the guest instead?

I get a 'no medium found' error from the 'dd..'

command. After

Quoted 1 line

going into the the monitor, ejecting and reloading the

disk,

Quoted 1 line

I still get the size of the first disk in the guest.

As I recall the old data is coming from the host page cache; it is not
seeing the media change. Try dropping the cache in the host on a media
change (echo 3 > /proc/sys/vm/drop_caches) or modify qemu to close and
reopen the cdrom device.

Quoted 1 line

David

I am able to reproduce this problem with just a plain kernel using the ata_piix driver, an initrd that just starts a shell, and plain qemu. When the disk is changed via the monitor, the guest invokes the error- handling code on the next read of the CD-ROM, but the code path doesn't trigger the 'update size' logic. I did an experiment where I placed the line 'sdev->changed = 1' in the sr_open method in sr.c of the guest kernel source, the size was updated, but I will look to see if there's something in qemu that can be changed to make it work properly.

Of course any input from the qemu/kvm developers is appreciated.

I code, therefore I am

Quoted 18 lines
Quoted 3 lines
Quoted 3 lines

I don't know how CD-ROM media change works on

real

Quoted 9 lines
Quoted 4 lines

hardware, but that
is the behavior that QEMU should be following.

Stefan

--
To unsubscribe from this list: send the line

"unsubscribe kvm" in

Quoted 3 lines

the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html