Voltage and current regulator: usage of 'regulators' parent node in device tree
Dear maintainer,
I see a lot of Device trees wrapping the regulator nodes within a parent node like this
regulators {
compatible = "simple-bus";
#address-cells = <1>;
#size-cells = <0>;
reg_p3v3: regulator@0 {
compatible = "regulator-fixed";
[...]
regulator-always-on;
};
[...]Contrary to that, patches exist removing the 'regulators' node, because the 'simple-bus' doesn't really exist in hardware. Unfortunately, the documentation is unclear about wrapping regulator nodes like shown above.
Should I avoid the parent 'regulators' node and why?
Is the given naming schema in fixed-regulator.yaml best practice to follow?
reg_xyz: regulator-xyz {
compatible = "regulator-fixed";
regulator-name = "xyz";Thank you for clarification.
Carsten Stelling
I'd really appreciate it, if you can give me feedback on my question. Thank you.
Quoted 31 lines
Dear maintainer,
I see a lot of Device trees wrapping the regulator nodes within a parent node like this
regulators { compatible = "simple-bus"; #address-cells = <1>; #size-cells = <0>; reg_p3v3: regulator@0 { compatible = "regulator-fixed"; [...] regulator-always-on; }; [...]Contrary to that, patches exist removing the 'regulators' node, because the 'simple-bus' doesn't really exist in hardware. Unfortunately, the documentation is unclear about wrapping regulator nodes like shown above.
Should I avoid the parent 'regulators' node and why?
Is the given naming schema in
fixed-regulator.yamlbest practice to follow?reg_xyz: regulator-xyz { compatible = "regulator-fixed"; regulator-name = "xyz";Thank you for clarification.
Carsten Stelling
Quoted 17 lines · embedded (VIVAVIS AG)
Dear maintainer,
I see a lot of Device trees wrapping the regulator nodes within a parent node like this
regulators { compatible = "simple-bus"; #address-cells = <1>; #size-cells = <0>; reg_p3v3: regulator@0 { compatible = "regulator-fixed"; [...] regulator-always-on; }; [...]
Quoted 5 lines
Contrary to that, patches exist removing the 'regulators' node, because the 'simple-bus' doesn't really exist in hardware. Unfortunately, the documentation is unclear about wrapping regulator nodes like shown above.
Should I avoid the parent 'regulators' node and why?
Yes and no. Yes, in the above case as there is no bus nor grouping of fixed regulators. For a MFD that includes regulators, then a child 'regulators' node is appropriate. To put it another way, if you have a schema defining a 'regulators' node, then it probably is appropriate.
Quoted 5 lines
Is the given naming schema in
fixed-regulator.yamlbest practice to follow?reg_xyz: regulator-xyz { compatible = "regulator-fixed"; regulator-name = "xyz";
Yes, pretty much.
Rob
Hi Rob,
Quoted 32 lines
Quoted 17 lines · embedded (VIVAVIS AG)
Dear maintainer,
I see a lot of Device trees wrapping the regulator nodes within a parent node like this
regulators { compatible = "simple-bus"; #address-cells = <1>; #size-cells = <0>; reg_p3v3: regulator@0 { compatible = "regulator-fixed"; [...] regulator-always-on; }; [...]Quoted 5 lines
Contrary to that, patches exist removing the 'regulators' node, because the 'simple-bus' doesn't really exist in hardware. Unfortunately, the documentation is unclear about wrapping regulator nodes like shown above.
Should I avoid the parent 'regulators' node and why?
Yes and no. Yes, in the above case as there is no bus nor grouping of fixed regulators. For a MFD that includes regulators, then a child 'regulators' node is appropriate. To put it another way, if you have a schema defining a 'regulators' node, then it probably is appropriate.
Quoted 2 lines
Is the given naming schema in
fixed-regulator.yamlbest practice to follow?
Quoted 7 lines
Quoted 3 lines
reg_xyz: regulator-xyz { compatible = "regulator-fixed"; regulator-name = "xyz";Yes, pretty much.
Rob
Think I understand.
MFD might be an integrated power management controller connected to an I2C bus or kind of GPIO. In this case the regulators node is used as child node under the node describing the PMIC. Found this binding example for MAX8997 /devicetree/bindings/regulator/max8997-regulator.txt.
max8997_pmic@66 {
compatible = "maxim,max8997-pmic";
<snip>
regulators: { // child node here
regulators {
ldo1_reg: LDO1 {
regulator-name = "VDD_ABB_3.3V";
regulator-min-microvolt = <3300000>;
regulator-max-microvolt = <3300000>;
};
ldo2_reg: LDO2 {
regulator-name = "VDD_ALIVE_1.1V";
regulator-min-microvolt = <1100000>;
regulator-max-microvolt = <1100000>;
regulator-always-on;
};
buck1_reg: BUCK1 {
regulator-name = "VDD_ARM_1.2V";
regulator-min-microvolt = <950000>;
regulator-max-microvolt = <1350000>;
regulator-always-on;
regulator-boot-on;
};
};
};To describe my simple 3.3V and 5.0V voltage regulators on the board (not integrated in a PMIC nor connected to a bus), I should not use the regulators node and put their descriptions to the root node.
reg_3v3: regulator-3v3 {
compatible = "regulator-fixed";
regulator-name = "3v3";
regulator-min-microvolt = <3300000>;
regulator-max-microvolt = <3300000>;
regulator-always-on;
};
reg_5v0: regulator-5v0 {
compatible = "regulator-fixed";
regulator-name = "5v0";
regulator-min-microvolt = <5000000>;
regulator-max-microvolt = <5000000>;
regulator-always-on;
};Thank you very much.
Carsten