Adaptec AHA-2940U2W "Data Parity Error Dectected" messages
I recently installed a SCSI tape drive and Adaptec AHA-2940U2W SCSI controller into my server to run backups.
Since then, the driver issues these warnings on a semi-regular basis while the drive is busy:
Aug 9 17:00:26 anu kernel: scsi0: Data Parity Error Detected during address or write data phase Aug 9 17:00:26 anu kernel: scsi0: PCI error Interrupt at seqaddr = 0x8
[...]
Aug 9 17:03:34 anu kernel: scsi0: Data Parity Error Detected during address or write data phase
[...]
Aug 9 17:04:36 anu kernel: scsi0: PCI parity error checking has been disabled. Aug 9 17:04:36 anu kernel: scsi0: Some device on this bus is generating bad parity. Aug 9 17:04:36 anu kernel: scsi0: This is an error *observed by*, not *generated by*, this controller. Aug 9 17:04:36 anu kernel: scsi0: Too many PCI parity errors observed as a target. Aug 9 17:04:36 anu kernel: scsi0: WARNING WARNING WARNING WARNING
Now, the log message claims that the SCSI controller is not responsible for these parity errors, so my questions are:
* should I panic about this?
* should I have seen this before the SCSI controller was installed?
* can I do anything about it, or identifying the cause?
Thanks,
Daniel
Quoted 8 lines · Daniel Pittman
I recently installed a SCSI tape drive and Adaptec AHA-2940U2W SCSI controller into my server to run backups.
Since then, the driver issues these warnings on a semi-regular basis while the drive is busy:
Aug 9 17:00:26 anu kernel: scsi0: Data Parity Error Detected during address or write data phase Aug 9 17:00:26 anu kernel: scsi0: PCI error Interrupt at seqaddr = 0x8
Make sure the hardware is all installed correctly. Check that the card is fully seated, or try it in another PCI slot. Also check your cabling and termination.
Lee
Quoted 4 lines · Lee Revell
Quoted 3 lines · Daniel Pittman
I recently installed a SCSI tape drive and Adaptec AHA-2940U2W SCSI controller into my server to run backups.
Quoted 8 lines
Quoted 5 lines
Since then, the driver issues these warnings on a semi-regular basis while the drive is busy:
Aug 9 17:00:26 anu kernel: scsi0: Data Parity Error Detected during address or write data phase Aug 9 17:00:26 anu kernel: scsi0: PCI error Interrupt at seqaddr = 0x8Make sure the hardware is all installed correctly. Check that the card is fully seated, or try it in another PCI slot.
Thanks. I will take the server down shortly and give that a shot.
Quoted 1 line
Also check your cabling and termination.
Could SCSI cabling and/or termination cause the card to report *PCI* errors, or am I misunderstanding these messages?
I guess that the fact that the "PCI" bit kept showing up in them is what confuses me. I didn't except a SCSI card to report PCI bus issues through the Linux driver, and since it claimed to be a victim, not a cause, I didn't know quite how to trace the problem down...
Thanks,
Daniel