PE 2450 with flashing health light and PERC Raid utility says Raid status is critical
I have a PE 2450 here that has had a flashing orange health light for a couple of months now. I scheduled some downtime for it last night to investigate. The raid utility says that RAID0 (a raid 5 array with 3 18G drives, the only raid array on the system and the only drives in the system) is critical, but it does not tell me why or what is wrong. It lists all 3 disks and it doesn't show any errors for them at all.
This server is running redhat 6.2 and kernel 2.2.14-6.1.1smp, loading the percraid kernel module. It has been running fine now for quite some time but I would like to figure out if there is really a problem or not.
After rebooting it the health light on the front of the server is now solid green, which I think is how it should be if there are no problems. But, during bootup I still see the error from the scsi card saying that the raid is critical.
I came accross this site:
http://www.redflag-linux.com/ppd/product_files/2003-AP001-01-01/base_doc/Dell_AACRAID.htm
And installed the Dell command line interface software from:
http://www.domsch.com/linux/aacraid/afaapps-2.6-0.tar.gz
I then can use the software and get the following for output:
FASTCMD> controller list
Executing: controller list
Adapter Name Adapter Type Availability Clustering ------------ ------------ ------------ ------------ afa0 PERC 3/Si read/write No_controller show > open afa0
Executing: open "afa0"
_controller show > controller show channels
Executing: controller show channels
Ch# Host ID Targets Type Max Usage
--- ------- ------- --------- ---------
0 7 15 Ultra160 NoInfo
_controller firmware > disk list
Executing: disk list
B:ID:L Device Type Blocks Bytes/Block Usage Shared Rate ------ -------------- --------- ----------- ---------------- ------ ---- 0:00:0 Disk 35566478 512 Initialized NO 160
0:01:0 Disk 35566478 512 Initialized NO 160
0:02:0 Disk 35566478 512 Initialized NO 160
AFA0> disk show defects 0
Executing: disk show defects (ID=0)
Number of PRIMARY defects on drive: 951
Number of GROWN defects on drive: 0
AFA0> disk show defects 1
Executing: disk show defects (ID=1)
Number of PRIMARY defects on drive: 641
Number of GROWN defects on drive: 0
AFA0> disk show defects 2
Executing: disk show defects (ID=2)
Number of PRIMARY defects on drive: 168
Number of GROWN defects on drive: 0
_enclosure identify > enclosure list
Executing: enclosure list
Enclosure
ID (B:ID:L) Fan Power Slot Sensor Door Speaker Standard Diagnostic ----------- --- ----- ---- ------ ---- -------- -------- ---------- 0 0:06:0 0 0 4 2 0 No SAF-TE PASSED
_enclosure identify > enclosure show status
Executing: enclosure show status
Enclosure
ID (B:ID:L) UpTime D:H:M PowerCycle Interval Door Alarm ----------- -------------- ---------- -------- -------- ----- 0 0:06:0 0:00:00 0 10 UNLOCKED OFF
Enclosure
ID (B:ID:L) Fan Status
----------- --- -------------
Enclosure
ID (B:ID:L) Power State Status
----------- ----- ------------ -------
Enclosure
ID (B:ID:L) Slot scsiId Insert Status
----------- ---- ------ ------- ------------------------------------------ 0 0:06:0 0 0:00:0 1 OK FAILED CRITICAL ACTIVATE
0 0:06:0 1 0:01:0 1 OK FAILED CRITICAL ACTIVATE
0 0:06:0 2 0:02:0 1 OK FAILED CRITICAL ACTIVATE
0 0:06:0 3 0:255:0 0 OK UNCONFIG EMPTY I/R READY NOTACTIVATE
Enclosure
ID (B:ID:L) Sensor Temperature Threshold Status
----------- ------ ----------- --------- --------
0 0:06:0 0 73 F 120 NORMAL
0 0:06:0 1 86 F 120 NORMAL
Pretty cool software but it's still not telling where the problem is. Could it be flaky software on the PERC controller, and there really isn't a problem?
Any help would be really appreciated.
Thanks