Raid 6 - TLER/CCTL/ERC
Subsystems (2)
Hey all,
I have a question regarding Linux raid and degraded arrays.
My configuration involves:
- 8x Samsung HD103UJ 1TB drives (terrible consumer-grade)
- AOC-USAS-L8i Controller
- CentOS 5.5 2.6.18-194.11.1.el5xen (64-bit)
- Each drive has one maximum-sized partition.
- 8-drives are configured in a raid 6.
My understanding is that with a raid 6, if a disk cannot return a given sector, it should still be possible to get what should have been returned from the first disk, from two other disks. My understanding is also that if this is successful, this should be written back to the disk that originally failed to read the given sector. I'm assuming that's what a message such as this indicates:
Sep 17 04:01:12 doorstop kernel: raid5:md0: read error corrected (8 sectors at 1647989048 on sde1)
I was hoping to confirm my suspicion on the meaning of that message.
On occasion, I'll also see this:
Oct 1 01:50:53 doorstop kernel: raid5:md0: read error not correctable (sector 1647369400 on sdh1).
This seems to involved the drive being kicked from the array, even though the drive is still readable for the most part (save for a few sectors).
What exactly is the criteria for a disk being kicked out of an array?
Furthermore, if an 8-disk raid 6 is running on the bare-minimum 6-disks, why on earth would it kick any more disks out? At this point, doesn't it makes sense to simply return an error to whatever tried to read from that part of the array instead of killing the array?
In other words, I would rather be able to read from a degraded raid-6 using something like dd with "conv=sync,noerror" (as I would be able to expect with a single disk with some bad sectors), than have it kick out the last drive that it can possibly run on, and die completely. Is there a good reason for this behavior?
Finally, why do the kernel messages that all say "raid5:" when it is clearly a raid 6?:
<snip>
[root@doorstop log]# cat /proc/mdstat
Personalities : [raid0] [raid6] [raid5] [raid4]
md0 : active raid6 sdc1[8](F) sdf1[7] sde1[6] sdd1[5] sda1[3] sdb1[1]
5860559616 blocks level 6, 64k chunk, algorithm 2 [8/5] [_U_U_UUU]
unused devices: <none>
</snip>
As for intimate details about the behavior of the drives themselves, I've noticed the following:
- Over time, each disk develops a slowly increasing number of "Current_Pending_Sector" (ID 197).
- The pending sector count returns to zero if a disk is removed from an array and filled with /dev/zero, or random data.
- Interestingly, on some occasions, the pending sector count did not return to zero after wiping the partition i.e. /dev/sda1.
- It did, however, return to zero when wiping the entire disk (/dev/sda)
- I had a feeling that this was the result of the drive "reading ahead", into the small area of unusable space after the first partition, and before the end of the disk, and then making note of this in SMART, but not necessarily causing a noticeable problem, as the sector was never actually requested by the kernel.
- I dd'd just that part of the drive, and the pending sectors went away in those cases
- I have on rare occasion had these drives go completely bad before (i.e., there were non-zero values for either "Reallocated_Event_Count", "Reallocated_Sector_Ct", or "Offline_Uncorrectable" (#196, #5, #198, respectively), and the drive seemed unwilling to read any sectors. These were RMA'd.
- As for the other drives, again, pending sectors do crop up, and always disappear when written to. I do not consider these drives bad. Flaky, sure. Slow to respond on error? Almost undoubtedly.
Finally, I should mention that I have tried the smartctl erc commands:
http://www.csc.liv.ac.uk/~greg/projects/erc/
I could not pass them through the controller I was using, but was able to connect the drives to the controller on the motherboard, set the erc values, and still have drives dropping out.
As a terrible band-aid, if I make sure to remove a drive when I see pending sectors, nuke it with random data (or /dev/zero), and resync the array, I get the drive pending sector count to return to zero and the array is happy. Once I have too many drives with pending sectors, however, a resync is almost guaranteed to fail, and I end up having to copy my data off and rebuild the array.
Instead of scripting the above (which sadly, I have done), is there any hope of saving the investment in disks? I have a feeling that this is simply something hitting a timeout, and likely causing problems for many more than just myself.
I greatly appreciate the time taken to read this, and any feedback provided.
Thank you,
Peter Zieba
312-285-3794
Quoted 12 lines · Peter Zieba
Hey all,
I have a question regarding Linux raid and degraded arrays.
My configuration involves:
- 8x Samsung HD103UJ 1TB drives (terrible consumer-grade)
- AOC-USAS-L8i Controller
- CentOS 5.5 2.6.18-194.11.1.el5xen (64-bit)
- Each drive has one maximum-sized partition.
- 8-drives are configured in a raid 6.My understanding is that with a raid 6, if a disk cannot return a given sector, it should still be possible to get what should have been returned from the first disk, from two other disks. My understanding is also that if this is successful, this should be written back to the disk that originally failed to read the given sector. I'm assuming that's what a message such as this indicates:
Quoted 8 lines
Sep 17 04:01:12 doorstop kernel: raid5:md0: read error corrected (8 sectors at 1647989048 on sde1)I was hoping to confirm my suspicion on the meaning of that message.
On occasion, I'll also see this:
Oct 1 01:50:53 doorstop kernel: raid5:md0: read error not correctable (sector 1647369400 on sdh1).This seems to involved the drive being kicked from the array, even though the drive is still readable for the most part (save for a few sectors).
[snip /]
Hi Peter,
For read errors that aren't permanent (gone after writing to the affected sectors), a "repair" action is your friend. I used to deal with occasional kicked-out drives in my arrays until I started running the following script in a weekly cron job:
#!/bin/bash
#
for x in /sys/block/md*/md/sync_action ; do
echo repair >$x
done
HTH,
Phil
Quoted 3 lines · Peter Zieba
- AOC-USAS-L8i Controller
I could not pass them through the controller I was using, but was able to connect the drives to the controller on the motherboard, set the erc values, and still have drives dropping out.
This controller uses the LSI 1068 controller chip and up until kernel 2.6.36, is likely to offline attached drives if smartctl or smartd is used.
If you update to this kernel or later , or apply the one line patch to the LSI driver in earlier ones, you will be able to safely use these monitoring utilities.
Patch as outined by the author on the bug list and subsequently accepted by LSI:
"It seems the mptsas driver could use blk_queue_dma_alignment() to advertise a stricter alignment requirement. If it does, sd does the right thing and bounces misaligned buffers (see block/blk-map.c line 57). The following patch to 2.6.34-rc5 makes my symptoms go away. I'm sure this is the wrong place for this code, but it gets my idea across."
drivers/message/fusion/mptscsih.c +2 -0
@@ -2450,6 +2450,8 @@ mptscsih_slave_configure(struct scsi_device *sdev) ioc->name,sdev->tagged_supported, sdev->simple_tags, sdev->ordered_tags)); +blk_queue_dma_alignment (sdev->request_queue,512 -1 ); +return 0 ; }
Regards,
Richard
Quoted 6 lines · Peter Zieba
Hey all,
I have a question regarding Linux raid and degraded arrays.
My configuration involves:
- 8x Samsung HD103UJ 1TB drives (terrible consumer-grade)
I have some of these drives too. I wouldn't go so far as to call them terrible, though 2 out of 3 did manage to get to a couple of pending sectors, which went away when I ran badblocks and haven't reappeared.
Quoted 9 lines
- AOC-USAS-L8i Controller
- CentOS 5.5 2.6.18-194.11.1.el5xen (64-bit)
- Each drive has one maximum-sized partition.
- 8-drives are configured in a raid 6.My understanding is that with a raid 6, if a disk cannot return a given sector, it should still be possible to get what should have been returned from the first disk, from two other disks. My understanding is also that if this is successful, this should be written back to the disk that originally failed to read the given sector. I'm assuming that's what a message such as this indicates:
Sep 17 04:01:12 doorstop kernel: raid5:md0: read error corrected (8 sectors at 1647989048 on sde1)I was hoping to confirm my suspicion on the meaning of that message.
Yup.
Quoted 4 lines
On occasion, I'll also see this:
Oct 1 01:50:53 doorstop kernel: raid5:md0: read error not correctable (sector 1647369400 on sdh1).This seems to involved the drive being kicked from the array, even though the drive is still readable for the most part (save for a few sectors).
The above indicates that a write failed. The drive should probably be replaced, though if you're seeing a lot of these I'd start suspecting cabling, drive chassis and/or SATA controller problems.
Hmm, is yours the SATA controller that doesn't like SMART commands? Or at least didn't in older kernels? Do you run smartd? Try without it for a bit... If that helps, look on Red Hat bugzilla and perhaps post a bug report.
Quoted 3 lines
What exactly is the criteria for a disk being kicked out of an array?
Furthermore, if an 8-disk raid 6 is running on the bare-minimum 6-disks, why on earth would it kick any more disks out? At this point, doesn't it makes sense to simply return an error to whatever tried to read from that part of the array instead of killing the array?
Because RAID isn't supposed to return bad data while bare drives are.
[...]
Quoted 1 line
Finally, why do the kernel messages that all say "raid5:" when it is clearly a raid 6?:
RAIDs 4, 5 and 6 are handled by the raid5 kernel module. Again I think the message has been changed in more recent kernels.
[...]
Quoted 4 lines
Finally, I should mention that I have tried the smartctl erc commands:
http://www.csc.liv.ac.uk/~greg/projects/erc/I could not pass them through the controller I was using, but was able to connect the drives to the controller on the motherboard, set the erc values, and still have drives dropping out.
Those settings don't stick across power cycles and presumably you powered the drives down to change which controller they were connected to, so your setting will have been lost.
Hope this helps.
Cheers,
John.
Quoted 10 lines · Peter Zieba
I have a question regarding Linux raid and degraded arrays.
My configuration involves:
- 8x Samsung HD103UJ 1TB drives (terrible consumer-grade)
- AOC-USAS-L8i Controller
- CentOS 5.5 2.6.18-194.11.1.el5xen (64-bit)
- Each drive has one maximum-sized partition.
- 8-drives are configured in a raid 6.My understanding is that with a raid 6, if a disk cannot return a given sector, it should still be possible to get what should have been returned from the first disk, from two other disks. My understanding is also that if this is successful, this should be written back to the disk that originally failed to read the given sector. I'm assuming that's what a message such as this indicates:
Quoted 8 lines
Sep 17 04:01:12 doorstop kernel: raid5:md0: read error corrected (8 sectors at 1647989048 on sde1)I was hoping to confirm my suspicion on the meaning of that message.
On occasion, I'll also see this:
Oct 1 01:50:53 doorstop kernel: raid5:md0: read error not correctable (sector 1647369400 on sdh1).This seems to involved the drive being kicked from the array, even though the drive is still readable for the most part (save for a few sectors).
Hi Peter,
I've just been in the *exact* same situation recently, so I can probably answer some of your questions (only as another end-user, though!). I'm using similar samsung drives (the consumer 1.5TB drives), the AOC-USASLP-L8i, and ubuntu kernels.
First off, I don't think the LSI1068E really works properly in any non-recent kernel; I was using 2.6.32 (stock Ubuntu 10.04 kernel), and having all sorts of problems with the card (read errors, bus errors, timeouts, etc.). I ended up going back to my old controller for a while. However, I've recently changed kernel (to 2.6.35) for other reasons (described below), and now the card is working fine. So I'm not sure how different it will be in CentOS, but you may want to consider trying a newer kernel in case the card is causing problems.
As for the read errors/kicking drives from the array, I'm not sure why it gets kicked reading some sectors and not others, however I know there were changes to the md stuff which handled that more gracefully earlier this year. I had the same problem -- on my 2.6.32 kernel, a rebuild of one drive would hit a bad sector on another and drop the drive, then hit another bad sector on a different drive and drop it as well, making the array unusable. However, with a 2.6.35 kernel it recovers gracefully and keeps going with the rebuild. (I can't find the exact patch, but Neil had it in an earlier email to me on the list; maybe a month or two ago?) So again, I'd suggest trying a newer kernel if you're having trouble.
Mind you, this is only as another end-user, not a developer, so I'm sure I've probably got something wrong in all that. :-) But that's what worked for me.
Hope that helps,
Michael