Hi,

I have a PowerMac G5. (Newer Model with SMU).
It has a Sungem ethernet with "PHY ID: 2060d2".

When this ethernet is connected to
"Tigon3 [partno(BCM95704A6) rev 2002 PHY(5704)] " or to the cisco switch, The PowerMac declares link up with 100 Mbs, while the other end declares link up with 1000Mbs. In this setup both end cannot ping each other.

If I lower the speed of Tigon based adapter or Cisco's switch port to 100Mbs, both end can ping each other.

Is it a bug? or Am I missing something?

Thanks in advance for the help.
Ajay

#1 lore raw
Quoted 11 lines · Ajay Patel

Hi,

I have a PowerMac G5. (Newer Model with SMU).
It has a Sungem ethernet with "PHY ID: 2060d2".

When this ethernet is connected to
"Tigon3 [partno(BCM95704A6) rev 2002 PHY(5704)] " or to the cisco switch, The PowerMac declares link up with 100 Mbs, while the other end declares link up with 1000Mbs. In this setup both end cannot ping each other.

Quoted 4 lines

If I lower the speed of Tigon based adapter or Cisco's switch port to 100Mbs, both end can ping each other.

Is it a bug? or Am I missing something?

I posted a patch that might fix it a while ago. What kernel version have you tested specifically ?