Hi. I have a 6 members raid5 set using software raid under linux. The array is comprised of 5 1 TB disks and a member that is a raid0 array of 2 500 MB disks. Use of the nested raid helped me do a transition of the system to this new array since I didn't have enough 1 TB drives. It has been working very reliably, but performance seems a little lackluster, and I have 2 new 1 TB drives of the same make and model that I would like to substitute.

I have always been taught that if you wanted to replace a disk in a raid5 array, you add the new disk as a member, and the fail the old disk and then remove it, which will cause the array to rebuild around the new disk.

But since all of the members are healthy, I was wondering if there was a way to replace the disk so I would not be running without redundancy during the rebuild process. That is, is there a way to swap the disk without failing the old member, but to basically have mdadm shadow the disk about to be replaced onto the new disk and then when it's in sync to remove the old disk. This seems like a much safer way of doing a swap, and since it takes about 12 hrs to do a resync, it is not a small amount of time where bad things could happen. I haven't seen anything that leads me to believe there is a way to do this, but thought I would ask here anyway before kicking off the process.

Also, since I have two new disks, I also want to grow the array by 1 TB (1 disk swaps out the old 2 member raid0 member of the raid5 array, and the new disk would expand the array) if there is a way to do the raid5 set rebuild and the grow at the same time? Since they both take a very long time to complete, and both are reading in the full contents of the all the members of the array, I was hoping to avoid this being done twice and save a lot of time. :-)

Thanks,
Mike

#1 lore raw
Quoted 13 lines · Mike Myers

Hi. I have a 6 members raid5 set using software raid under linux. The array is comprised of 5 1 TB disks and a member that is a raid0 array of 2 500 MB disks. Use of the nested raid helped me do a transition of the system to this new array since I didn't have enough 1 TB drives. It has been working very reliably, but performance seems a little lackluster, and I have 2 new 1 TB drives of the same make and model that I would like to substitute.

I have always been taught that if you wanted to replace a disk in a raid5 array, you add the new disk as a member, and the fail the old disk and then remove it, which will cause the array to rebuild around the new disk.

Quoted 10 lines

But since all of the members are healthy, I was wondering if there was a way to replace the disk so I would not be running without redundancy during the rebuild process. That is, is there a way to swap the disk without failing the old member, but to basically have mdadm shadow the disk about to be replaced onto the new disk and then when it's in sync to remove the old disk. This seems like a much safer way of doing a swap, and since it takes about 12 hrs to do a resync, it is not a small amount of time where bad things could happen. I haven't seen anything that leads me to believe there is a way to do this, but thought I would ask here anyway before kicking off the process.

There are a couple paths you could take here depending on how the current array is used. The first is you could down the array and just use dd to copy the contents of the two 500mb disks to the 1tb disk. This implies you *can* down the array. If that's not possible, then I would suggest you run a check of the array first (echo "check"

Quoted 1 line

/sys/block/md<devnum>/md/sync_action). This will scan all the drives

and pick out any bad sectors waiting to happen and then rewrite them with good data. This helps to prevent any bad things from happening after you remove the good device and start the rebuild on the spare device. I don't know of a way to make the md stack start that rebuild before you fail the old device though, so this is the best suggestion I've got, and it's not 100% guaranteed as you could develop a bad sector after the check pass completes (although chances of that are very slim).

Quoted 7 lines

Also, since I have two new disks, I also want to grow the array by 1 TB (1 disk swaps out the old 2 member raid0 member of the raid5 array, and the new disk would expand the array) if there is a way to do the raid5 set rebuild and the grow at the same time? Since they both take a very long time to complete, and both are reading in the full contents of the all the members of the array, I was hoping to avoid this being done twice and save a lot of time. :-)

Neil would need to answer that. Honestly, I doubt it. By the time you include the check pass, I think you are going to need to do three passes of the array to replace the raid set and grow it. But, I could be wrong.

Signature · 6 lines
Doug Ledford <[email protected]>
              GPG KeyID: CFBFF194
              http://people.redhat.com/dledford

Infiniband specific RPMs available at
              http://people.redhat.com/dledford/Infiniband
author
#2 lore raw

Thanks. I hadn't heard of the "check" technique. Is that described somewhere? It should be in the software raid howto.

I just initiated a "check" on the array, so we'll see how that goes....

thx
mike

----- Original Message ----
From: Doug Ledford <[email protected]>
To: Mike Myers <[email protected]>
Cc: [email protected]
Sent: Tuesday, November 11, 2008 1:21:30 PM
Subject: Re: Swapping a disk in a raid5 array

Quoted 13 lines · Mike Myers

Hi. I have a 6 members raid5 set using software raid under linux. The array is comprised of 5 1 TB disks and a member that is a raid0 array of 2 500 MB disks. Use of the nested raid helped me do a transition of the system to this new array since I didn't have enough 1 TB drives. It has been working very reliably, but performance seems a little lackluster, and I have 2 new 1 TB drives of the same make and model that I would like to substitute.

I have always been taught that if you wanted to replace a disk in a raid5 array, you add the new disk as a member, and the fail the old disk and then remove it, which will cause the array to rebuild around the new disk.

Quoted 10 lines

But since all of the members are healthy, I was wondering if there was a way to replace the disk so I would not be running without redundancy during the rebuild process. That is, is there a way to swap the disk without failing the old member, but to basically have mdadm shadow the disk about to be replaced onto the new disk and then when it's in sync to remove the old disk. This seems like a much safer way of doing a swap, and since it takes about 12 hrs to do a resync, it is not a small amount of time where bad things could happen. I haven't seen anything that leads me to believe there is a way to do this, but thought I would ask here anyway before kicking off the process.

There are a couple paths you could take here depending on how the current array is used. The first is you could down the array and just use dd to copy the contents of the two 500mb disks to the 1tb disk. This implies you *can* down the array. If that's not possible, then I would suggest you run a check of the array first (echo "check"

Quoted 1 line

/sys/block/md<devnum>/md/sync_action). This will scan all the drives

and pick out any bad sectors waiting to happen and then rewrite them with good data. This helps to prevent any bad things from happening after you remove the good device and start the rebuild on the spare device. I don't know of a way to make the md stack start that rebuild before you fail the old device though, so this is the best suggestion I've got, and it's not 100% guaranteed as you could develop a bad sector after the check pass completes (although chances of that are very slim).

Quoted 7 lines

Also, since I have two new disks, I also want to grow the array by 1 TB (1 disk swaps out the old 2 member raid0 member of the raid5 array, and the new disk would expand the array) if there is a way to do the raid5 set rebuild and the grow at the same time? Since they both take a very long time to complete, and both are reading in the full contents of the all the members of the array, I was hoping to avoid this being done twice and save a lot of time. :-)

Neil would need to answer that. Honestly, I doubt it. By the time you include the check pass, I think you are going to need to do three passes of the array to replace the raid set and grow it. But, I could be wrong.

Signature · 6 lines
Doug Ledford <[email protected]>
              GPG KeyID: CFBFF194
              http://people.redhat.com/dledford

Infiniband specific RPMs available at
              http://people.redhat.com/dledford/Infiniband
#3 lore raw
Quoted 1 line · Mike Myers

Thanks. I hadn't heard of the "check" technique. Is that described somewhere? It should be in the software raid howto.

<http://linux-raid.osdl.org/index.php/RAID_Administration>

Debian/Ubuntu has this:

:/etc/cron.d$ grep check mdadm
# cron.d/mdadm -- schedules periodic redundancy checks of MD devices
57 0 * * 0 root [ -x /usr/share/mdadm/checkarray ] && [ $(date +\%d) -le 7 ] && /usr/share/mdadm/checkarray --cron --all --quiet

This will do the same thing once a month.

Signature · 1 line
Mikael Abrahamsson    email: [email protected]
#4 lore raw
In reply to Mike Myers
Quoted 1 line · Mike Myers

Is that described somewhere? It should be in the software raid howto.

Documentation/md.txt in the kernel source.

Regards,

Richard