units for latency in --minimal mode
While describing the output format, the HOWTO says:
slat= [...] This
value can be in milliseconds or microseconds, fio will choose the most appropriate base and print that. In the example above, milliseconds is the best scale.
Does this apply to --minimal mode too?
--
Lucian
Quoted 8 lines · Lucian Grijincu
While describing the output format, the HOWTO says:
slat= [...] This
value can be in milliseconds or microseconds, fio will choose the most appropriate base and print that. In the example above, milliseconds is the best scale.Does this apply to --minimal mode too?
No, the minimal output is always in usecs. Feel free to send me a patch to improve the HOWTO wording there, you are not the first to ask :-)
Signature · 1 line
Jens Axboe