Applied "regulator: Convert to using %pOF instead of full_name" to the regulator tree
Subsystems (3)
Mark Brown
maintainerThe patch
regulator: Convert to using %pOF instead of full_name
has been applied to the regulator tree at
git://git.kernel.org/pub/scm/linux/kernel/git/broonie/regulator.git
All being well this means that it will be integrated into the linux-next tree (usually sometime in the next 24 hours) and sent to Linus during the next merge window (or sooner if it is a bug fix), however if problems are discovered then the patch may be dropped or reverted.
You may get further e-mails resulting from automated or manual testing and review of the tree, please engage with people reporting problems and send followup patches addressing any issues that are reported if needed.
If any updates are required or you are submitting further changes they should be sent as incremental updates against current git, existing patches will not be replaced.
Please add any relevant lists and maintainers to the CCs when replying to this mail.
Thanks,
Mark
Quoted 1 line
From
7799167b7a14feb17c258fb33a02c61eb54f67d1Mon Sep 17 00:00:00 2001
From: Rob Herring <[email protected]>
Date: Tue, 18 Jul 2017 16:43:26 -0500
Subject: [PATCH] regulator: Convert to using %pOF instead of full_name
Now that we have a custom printf format specifier, convert users of full_name to use %pOF instead. This is preparation to remove storing of the full path string for each node.
--- drivers/regulator/core.c | 4 ++-- drivers/regulator/max1586.c | 2 +- drivers/regulator/s5m8767.c | 4 ++-- drivers/reset/reset-socfpga.c | 4 ++-- 4 files changed, 7 insertions(+), 7 deletions(-)
drivers/regulator/core.c +2 -2
@@ -204,8 +204,8 @@ static struct device_node *of_get_regulator(struct device *dev, const char *supp regnode =of_parse_phandle (dev->of_node, prop_name,0 );if (!regnode) { -dev_dbg (dev,"Looking up %s property in node %s failed\n" , - prop_name, dev->of_node->full_name); +dev_dbg (dev,"Looking up %s property in node %pOF failed\n" , + prop_name, dev->of_node);return NULL ; }return regnode;
drivers/regulator/max1586.c +1 -1
@@ -169,7 +169,7 @@ static int of_get_max1586_platform_data(struct device *dev,if (of_property_read_u32 (np,"v3-gain" , &pdata->v3_gain) <0 ) { -dev_err (dev,"%s has no 'v3-gain' property\n" , np->full_name); +dev_err (dev,"%pOF has no 'v3-gain' property\n" , np);return -EINVAL ; }
drivers/regulator/s5m8767.c +2 -2
@@ -590,8 +590,8 @@ static int s5m8767_pmic_dt_parse_pdata(struct platform_device *pdev,if (of_property_read_u32 (reg_np,"op_mode" , &rmode->mode)) {dev_warn (iodev->dev, -"no op_mode property property at %s\n" , - reg_np->full_name); +"no op_mode property property at %pOF\n" , + reg_np); rmode->mode =S5M8767_OPMODE_NORMAL_MODE ; }
drivers/reset/reset-socfpga.c +2 -2
@@ -109,8 +109,8 @@ static int socfpga_reset_probe(struct platform_device *pdev)* Do not continue, when we encounter an old DT. */ if (!of_find_property (pdev->dev.of_node,"#reset-cells" ,NULL )) { -dev_err (&pdev->dev,"%s missing #reset-cells property\n" , - pdev->dev.of_node->full_name); +dev_err (&pdev->dev,"%pOF missing #reset-cells property\n" , + pdev->dev.of_node);return -EINVAL ; }
Signature · 1 line
2.13.2