Skip to contentSkip to conversation

Crosschip bridge functionality

DISCUSSION Colin Foster 3 participants 10 messages Dec 23, 2022 – Jan 3, 2023

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

Hello,

I've been looking into what it would take to add the Distributed aspect to the Felix driver, and I have some general questions about the theory of operation and if there are any limitations I don't foresee. It might be a fair bit of work for me to get hardware to even test, so avoiding dead ends early would be really nice!

Also it seems like all the existing Felix-like hardware is all integrated into a SOC, so there's really no other potential users at this time.

For a distributed setup, it looks like I'd just need to create felix_crosschip_bridge_{join,leave} routines, and use the mv88e6xxx as a template. These routines would create internal VLANs where, assuming they use a tagging protocol that the switch can offload (your documentation specifically mentions Marvell-tagged frames for this reason, seemingly) everything should be fully offloaded to the switches.

What's the catch?

In the Marvell case, is there any gotcha where "under these scenarios, the controlling CPU needs to process packets at line rate"?

Thanks for all the great documentation and guidance! (and patience)

Colin Foster

#1 lore raw
Quoted 12 lines · Colin Foster

Hello,

I've been looking into what it would take to add the Distributed aspect to the Felix driver, and I have some general questions about the theory of operation and if there are any limitations I don't foresee. It might be a fair bit of work for me to get hardware to even test, so avoiding dead ends early would be really nice!

Also it seems like all the existing Felix-like hardware is all integrated into a SOC, so there's really no other potential users at this time.

Quoted 8 lines

For a distributed setup, it looks like I'd just need to create felix_crosschip_bridge_{join,leave} routines, and use the mv88e6xxx as a template. These routines would create internal VLANs where, assuming they use a tagging protocol that the switch can offload (your documentation specifically mentions Marvell-tagged frames for this reason, seemingly) everything should be fully offloaded to the switches.

What's the catch?

I actually think you need silicon support for this. Earlier versions of the Marvell Switches are missing some functionality, which results in VLANs leaking in distributed setups. I think the switches also share information between themselves, over the DSA ports, i.e. the ports between switches.

I've no idea if you can replicate the Marvell DSA concept with VLANs. The Marvell header has D in DSA as a core concept. The SoC can request a frame is sent out a specific port of a specific switch. And each switch has a routing table which indicates what egress port to use to go towards a specific switch. Frames received at the SoC indicate both the ingress port and the ingress switch, etc.

Quoted 2 lines

In the Marvell case, is there any gotcha where "under these scenarios, the controlling CPU needs to process packets at line rate"?

None that i know of. But i'm sure Marvell put a reasonable amount of thought into how to make a distributed switch. There is at least one patent covering the concept. It could be that a VLAN based re-implemention could have such problems.

Andrew

#2 lore raw
Quoted 28 lines · Andrew Lunn
Quoted 12 lines · Colin Foster

Hello,

I've been looking into what it would take to add the Distributed aspect to the Felix driver, and I have some general questions about the theory of operation and if there are any limitations I don't foresee. It might be a fair bit of work for me to get hardware to even test, so avoiding dead ends early would be really nice!

Also it seems like all the existing Felix-like hardware is all integrated into a SOC, so there's really no other potential users at this time.

Quoted 8 lines

For a distributed setup, it looks like I'd just need to create felix_crosschip_bridge_{join,leave} routines, and use the mv88e6xxx as a template. These routines would create internal VLANs where, assuming they use a tagging protocol that the switch can offload (your documentation specifically mentions Marvell-tagged frames for this reason, seemingly) everything should be fully offloaded to the switches.

What's the catch?

I actually think you need silicon support for this. Earlier versions of the Marvell Switches are missing some functionality, which results in VLANs leaking in distributed setups. I think the switches also share information between themselves, over the DSA ports, i.e. the ports between switches.

Quoted 6 lines

I've no idea if you can replicate the Marvell DSA concept with VLANs. The Marvell header has D in DSA as a core concept. The SoC can request a frame is sent out a specific port of a specific switch. And each switch has a routing table which indicates what egress port to use to go towards a specific switch. Frames received at the SoC indicate both the ingress port and the ingress switch, etc.

"It might not work at all" is definitely a catch :-)

I haven't looked into the Marvell documentation about this, so maybe that's where I should go next. It seems Ocelot chips support double-tagging, which would lend itself to the SoC being able to determine which port and switch for ingress and egress... though that might imply it could only work with DSA ports on the first chip, which would be an understandable limitation.

Quoted 8 lines
Quoted 3 lines

In the Marvell case, is there any gotcha where "under these scenarios, the controlling CPU needs to process packets at line rate"?

None that i know of. But i'm sure Marvell put a reasonable amount of thought into how to make a distributed switch. There is at least one patent covering the concept. It could be that a VLAN based re-implemention could have such problems.

I'm starting to understand why there's only one user of crosschip_bridge_* functions. So this sounds to me like a "don't go down this path - you're in for trouble" scenario.

Thanks for the info!

Quoted 2 lines

Andrew

#3 lore raw
Quoted 28 lines
Quoted 8 lines
Quoted 1 line

What's the catch?

I actually think you need silicon support for this. Earlier versions of the Marvell Switches are missing some functionality, which results in VLANs leaking in distributed setups. I think the switches also share information between themselves, over the DSA ports, i.e. the ports between switches.

Quoted 6 lines

I've no idea if you can replicate the Marvell DSA concept with VLANs. The Marvell header has D in DSA as a core concept. The SoC can request a frame is sent out a specific port of a specific switch. And each switch has a routing table which indicates what egress port to use to go towards a specific switch. Frames received at the SoC indicate both the ingress port and the ingress switch, etc.

"It might not work at all" is definitely a catch :-)

I haven't looked into the Marvell documentation about this, so maybe that's where I should go next. It seems Ocelot chips support double-tagging, which would lend itself to the SoC being able to determine which port and switch for ingress and egress... though that might imply it could only work with DSA ports on the first chip, which would be an understandable limitation.

Quoted 4 lines
Quoted 3 lines

In the Marvell case, is there any gotcha where "under these scenarios, the controlling CPU needs to process packets at line rate"?

Quoted 8 lines
Quoted 4 lines

None that i know of. But i'm sure Marvell put a reasonable amount of thought into how to make a distributed switch. There is at least one patent covering the concept. It could be that a VLAN based re-implemention could have such problems.

I'm starting to understand why there's only one user of crosschip_bridge_* functions. So this sounds to me like a "don't go down this path - you're in for trouble" scenario.

What is your real use case here?

I know people have stacked switches before, and just operated them as stacked switches. So you need to configure each switch independently. What Marvell DSA does is make it transparent, so to some extent it looks like one big switch, not a collection of switches.

Andrew

#4 lore raw
Quoted 33 lines · Andrew Lunn
Quoted 33 lines
Quoted 8 lines
Quoted 1 line

What's the catch?

I actually think you need silicon support for this. Earlier versions of the Marvell Switches are missing some functionality, which results in VLANs leaking in distributed setups. I think the switches also share information between themselves, over the DSA ports, i.e. the ports between switches.

Quoted 6 lines

I've no idea if you can replicate the Marvell DSA concept with VLANs. The Marvell header has D in DSA as a core concept. The SoC can request a frame is sent out a specific port of a specific switch. And each switch has a routing table which indicates what egress port to use to go towards a specific switch. Frames received at the SoC indicate both the ingress port and the ingress switch, etc.

"It might not work at all" is definitely a catch :-)

I haven't looked into the Marvell documentation about this, so maybe that's where I should go next. It seems Ocelot chips support double-tagging, which would lend itself to the SoC being able to determine which port and switch for ingress and egress... though that might imply it could only work with DSA ports on the first chip, which would be an understandable limitation.

Quoted 8 lines
Quoted 3 lines

In the Marvell case, is there any gotcha where "under these scenarios, the controlling CPU needs to process packets at line rate"?

None that i know of. But i'm sure Marvell put a reasonable amount of thought into how to make a distributed switch. There is at least one patent covering the concept. It could be that a VLAN based re-implemention could have such problems.

Quoted 5 lines
Quoted 3 lines

I'm starting to understand why there's only one user of crosschip_bridge_* functions. So this sounds to me like a "don't go down this path - you're in for trouble" scenario.

What is your real use case here?

Fair question. We have a baseboard configuration with cards that offer customization / expansion. An example might be a card that offers additional fibre / copper ports, which would lend itself very nicely to a DSA configuration... more cards == more ports.

We can see some interesting use of vlans for all sorts of things. I haven't been the boots on the ground, so I don't know all the use-cases. My main hope is to be able to offer as much configurability for the system integrators as possible. Maybe sw2p2 is a tap of sw1p2, while sw2p3, sw2p4, and sw1p3 are bridged, with the CPU doing IGMP snooping and running RSTP.

Quoted 5 lines

I know people have stacked switches before, and just operated them as stacked switches. So you need to configure each switch independently. What Marvell DSA does is make it transparent, so to some extent it looks like one big switch, not a collection of switches.

That is definitely possible. It might make the people doing any system integration have a lot more knowledge than a simple "add this port to that bridge". My goal is to make their lives as easy as can be.

It sounds like that all exists with Marvell hardware...

#5 lore raw
Quoted 18 lines

Fair question. We have a baseboard configuration with cards that offer customization / expansion. An example might be a card that offers additional fibre / copper ports, which would lend itself very nicely to a DSA configuration... more cards == more ports.

We can see some interesting use of vlans for all sorts of things. I haven't been the boots on the ground, so I don't know all the use-cases. My main hope is to be able to offer as much configurability for the system integrators as possible. Maybe sw2p2 is a tap of sw1p2, while sw2p3, sw2p4, and sw1p3 are bridged, with the CPU doing IGMP snooping and running RSTP.

Quoted 5 lines

I know people have stacked switches before, and just operated them as stacked switches. So you need to configure each switch independently. What Marvell DSA does is make it transparent, so to some extent it looks like one big switch, not a collection of switches.

Quoted 5 lines

That is definitely possible. It might make the people doing any system integration have a lot more knowledge than a simple "add this port to that bridge". My goal is to make their lives as easy as can be.

It sounds like that all exists with Marvell hardware...

You might want get hold of a Turris Mox system, with a few different cards in it. That will give you a Marvell D in DSA system to play with. And your system seems quite similar in some ways.

Andrew

#6 lore raw
Quoted 3 lines · Andrew Lunn

You might want get hold of a Turris Mox system, with a few different cards in it. That will give you a Marvell D in DSA system to play with. And your system seems quite similar in some ways.

Indeed I do. Thanks Andrew!

#7 lore raw
In reply to Colin Foster

Hi Colin,

Quoted 48 lines · Colin Foster
Quoted 28 lines · Andrew Lunn
Quoted 12 lines · Colin Foster

Hello,

I've been looking into what it would take to add the Distributed aspect to the Felix driver, and I have some general questions about the theory of operation and if there are any limitations I don't foresee. It might be a fair bit of work for me to get hardware to even test, so avoiding dead ends early would be really nice!

Also it seems like all the existing Felix-like hardware is all integrated into a SOC, so there's really no other potential users at this time.

Quoted 8 lines

For a distributed setup, it looks like I'd just need to create felix_crosschip_bridge_{join,leave} routines, and use the mv88e6xxx as a template. These routines would create internal VLANs where, assuming they use a tagging protocol that the switch can offload (your documentation specifically mentions Marvell-tagged frames for this reason, seemingly) everything should be fully offloaded to the switches.

What's the catch?

I actually think you need silicon support for this. Earlier versions of the Marvell Switches are missing some functionality, which results in VLANs leaking in distributed setups. I think the switches also share information between themselves, over the DSA ports, i.e. the ports between switches.

Quoted 6 lines

I've no idea if you can replicate the Marvell DSA concept with VLANs. The Marvell header has D in DSA as a core concept. The SoC can request a frame is sent out a specific port of a specific switch. And each switch has a routing table which indicates what egress port to use to go towards a specific switch. Frames received at the SoC indicate both the ingress port and the ingress switch, etc.

"It might not work at all" is definitely a catch :-)

I haven't looked into the Marvell documentation about this, so maybe that's where I should go next. It seems Ocelot chips support double-tagging, which would lend itself to the SoC being able to determine which port and switch for ingress and egress... though that might imply it could only work with DSA ports on the first chip, which would be an understandable limitation.

Quoted 3 lines
Quoted 2 lines

In the Marvell case, is there any gotcha where "under these scenarios, the controlling CPU needs to process packets at line rate"?

Quoted 8 lines
Quoted 4 lines

None that i know of. But i'm sure Marvell put a reasonable amount of thought into how to make a distributed switch. There is at least one patent covering the concept. It could be that a VLAN based re-implemention could have such problems.

I'm starting to understand why there's only one user of crosschip_bridge_* functions. So this sounds to me like a "don't go down this path - you're in for trouble" scenario.

Trying to build on top of what Andrew has already replied.

Back when I was new to DSA and completely unqualified to be a DSA reviewer/ maintainer (it's debatable whether now I am), I actually had some of the same questions about what's possible in terms of software support, given the Vitesse architectural limitations for cross-chip bridging a la Marvell, in this email thread:
https://patchwork.kernel.org/project/linux-arm-kernel/patch/[email protected]/

That being said, you need to broaden your detection criteria for cross-chip bridging; sja1105 (and tag_8021q in general) supports this too, except it's a bit hidden from the ds->ops->crosschip_bridge_join() operation. It all relies on the concept of cross-chip notifier chain from switch.c. dsa_tag_8021q_bridge_join() will emit a DSA_NOTIFIER_TAG_8021Q_VLAN_ADD event, which the other tag_8021q capable switches in the system will see and react to.

Because felix and sja1105 each support a tagger based on tag_8021q for different needs, there is an important difference in their implementations. The comment in dsa_tag_8021q_bridge_join() - called by sja1105 but not by felix - summarizes the essence of the difference.

If Felix were to gain support for tag_8021q cross-chip bridging*, the driver would would need to look at the switch's position within the PCB topology. On the user ports, tag_8021q would have to be implemented using the VCAP TCAM rules, to retain support for VLAN-aware bridging and just push/pop the VLAN that serves as make-shift tag. On the DSA "cascade" ports, tag_8021q would have to be implemented using the VLAN table, in order to make the switch understand the tag that's already in the packet and route based on it, rather than push yet another one. The proper combination of VCAP rules and VLAN table entries needs much more consideration to cover all scenarios (CPU RX over a daisy chain; CPU TX over a daisy chain; autonomous forwarding over 2 switches; autonomous forwarding over 3 switches; autonomous forwarding between sja1105 and felix; forwarding done by felix for traffic originated by one sja1105 and destined to another sja1105; forwarding done by felix for traffic originated by a sja1105 and destined to a felix user port with no other downstream switch).

You might find some of my thoughts on this topic interesting, in the "Switch topology changes" chapter of this PDF:
https://lpc.events/event/11/contributions/949/attachments/823/1555/paper.pdf

With that development summary in mind, you'll probably be prepared to use "git log" to better understand some of the stages that tag_8021q cross-chip bridging has been through.

In principle, when comparing tag_8021q cross-chip bridging to something proprietary like Marvell, I consider it to be somewhat analogous to Russian/SSSR engineering: it's placed on the "good" side of the diminishing returns curve, or i.o.w., it works stupidly well for how simplistic it is. I could be interested to help if you come up with a sound proposal that addresses your needs and is generic enough that pieces of it are useful to others too.

*I seriously doubt that any hw manufacturer would be crazy enough to use Vitesse switches for an application for which they are essentially out of spec and out of their intended use. Yet that is more or less the one-sentence description of what we, at NXP, are doing with them, so I know what it's like and I don't necessarily discourage it ;) Generally I'd say they take a bit of pushing quite well (while failing at some arguably reasonable and basic use cases, like flow control on NPI port - go figure).

#8 lore raw
Quoted 8 lines · Vladimir Oltean

Hi Colin,

Quoted 4 lines · Colin Foster

On Fri, Dec 23, 2022 at 09:05:27PM +0100, Andrew Lunn wrote:
I'm starting to understand why there's only one user of crosschip_bridge_* functions. So this sounds to me like a "don't go down this path - you're in for trouble" scenario.

Quoted 8 lines

Trying to build on top of what Andrew has already replied.

Back when I was new to DSA and completely unqualified to be a DSA reviewer/ maintainer (it's debatable whether now I am), I actually had some of the same questions about what's possible in terms of software support, given the Vitesse architectural limitations for cross-chip bridging a la Marvell, in this email thread:
https://patchwork.kernel.org/project/linux-arm-kernel/patch/[email protected]/

Thank you for this link. I'll look it over. As usual, I'll need some time to absorb all this information :-)

Quoted 9 lines

That being said, you need to broaden your detection criteria for cross-chip bridging; sja1105 (and tag_8021q in general) supports this too, except it's a bit hidden from the ds->ops->crosschip_bridge_join() operation. It all relies on the concept of cross-chip notifier chain from switch.c. dsa_tag_8021q_bridge_join() will emit a DSA_NOTIFIER_TAG_8021Q_VLAN_ADD event, which the other tag_8021q capable switches in the system will see and react to.

Quoted 4 lines

Because felix and sja1105 each support a tagger based on tag_8021q for different needs, there is an important difference in their implementations. The comment in dsa_tag_8021q_bridge_join() - called by sja1105 but not by felix - summarizes the essence of the difference.

Hmm... So the Marvell and sja1105 both support "Distributed" but in slightly different ways?

Quoted 16 lines

If Felix were to gain support for tag_8021q cross-chip bridging*, the driver would would need to look at the switch's position within the PCB topology. On the user ports, tag_8021q would have to be implemented using the VCAP TCAM rules, to retain support for VLAN-aware bridging and just push/pop the VLAN that serves as make-shift tag. On the DSA "cascade" ports, tag_8021q would have to be implemented using the VLAN table, in order to make the switch understand the tag that's already in the packet and route based on it, rather than push yet another one. The proper combination of VCAP rules and VLAN table entries needs much more consideration to cover all scenarios (CPU RX over a daisy chain; CPU TX over a daisy chain; autonomous forwarding over 2 switches; autonomous forwarding over 3 switches; autonomous forwarding between sja1105 and felix; forwarding done by felix for traffic originated by one sja1105 and destined to another sja1105; forwarding done by felix for traffic originated by a sja1105 and destined to a felix user port with no other downstream switch).

^ This paragraph is what I need! Although I'm leaning very much torward the "run away" solution (and buying some fun hardware in the process) this is something I'll keep revisiting as I learn. If it isn't fall-off-a-log easy for you, I probably don't stand a chance.

Quoted 4 lines

You might find some of my thoughts on this topic interesting, in the "Switch topology changes" chapter of this PDF:
https://lpc.events/event/11/contributions/949/attachments/823/1555/paper.pdf

I'm well aware of this paper :-) I'll give it another re-read, as I always find new things.

Quoted 4 lines

With that development summary in mind, you'll probably be prepared to use "git log" to better understand some of the stages that tag_8021q cross-chip bridging has been through.

Yes, a couple key terms and a little background can go a very long way! Thanks.

Quoted 8 lines

In principle, when comparing tag_8021q cross-chip bridging to something proprietary like Marvell, I consider it to be somewhat analogous to Russian/SSSR engineering: it's placed on the "good" side of the diminishing returns curve, or i.o.w., it works stupidly well for how simplistic it is. I could be interested to help if you come up with a sound proposal that addresses your needs and is generic enough that pieces of it are useful to others too.

Great to know. I'm in a very early "theory only" stage of this. First things first - I need to button up full switch functionality and add another year to the Copyright notice.

Quoted 9 lines

*I seriously doubt that any hw manufacturer would be crazy enough to use Vitesse switches for an application for which they are essentially out of spec and out of their intended use. Yet that is more or less the one-sentence description of what we, at NXP, are doing with them, so I know what it's like and I don't necessarily discourage it ;) Generally I'd say they take a bit of pushing quite well (while failing at some arguably reasonable and basic use cases, like flow control on NPI port - go figure).

#9 lore raw
Quoted 8 lines · Colin Foster
Quoted 8 lines

That being said, you need to broaden your detection criteria for cross-chip bridging; sja1105 (and tag_8021q in general) supports this too, except it's a bit hidden from the ds->ops->crosschip_bridge_join() operation. It all relies on the concept of cross-chip notifier chain from switch.c. dsa_tag_8021q_bridge_join() will emit a DSA_NOTIFIER_TAG_8021Q_VLAN_ADD event, which the other tag_8021q capable switches in the system will see and react to.

Quoted 7 lines
Quoted 4 lines

Because felix and sja1105 each support a tagger based on tag_8021q for different needs, there is an important difference in their implementations. The comment in dsa_tag_8021q_bridge_join() - called by sja1105 but not by felix - summarizes the essence of the difference.

Hmm... So the Marvell and sja1105 both support "Distributed" but in slightly different ways?

Yes, the SJA1105 and SJA1110 switches can also be instantiated multiple times on the same board (under the same DSA master, forming a single tree), and have some awareness of each other. The hardware awareness is limited to PTP timestamping. Only leaf ports should take a MAC timestamp for a PTP event message. Cascade ports must be configured to forward that packet timestamp to the CPU and not generate a new one. Otherwise, the forwarding plane is basically unaware of a multi-switch DSA tree. The reasoning of the designers was that it doesn't even need to be, since non-proprietary mechanisms such as VLANs can be used to restrict the forwarding domain as desired. The cross-chip support in tag_8021q follows that idea and programs some reserved VLANs to the ports that need them.