Skip to contentSkip to conversation

riscv: Can a valid LR/SC sequence have a backward branch on a failure path?

RFC Vladimir Kondratiev 1 participant 1 message Nov 17

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

Hi all,

I have run into a question regarding LR/SC sequence constraints: can a valid constrained LR/SC sequence contain a backward branch on a failure path?

Consider this CAS example, where I placed the failure path before the LR/SC sequence:

cas:

j 1f

2:

	li a0, -1

	ret

1:

	lr.w   t0, (a0)

	bne    t0, a1, 2b

	sc.w   t0, a2, (a0)

	bnez   t0, 1b

	li     a0, 0

	ret

The rules in [1] prohibit taken backward branches within the sequence. In this example, the backward branch (2b) is not taken when LR/SC successfully completes; it is only taken on the failure path.

My context is control flow graph (CFG) analysis when detecting whether a particular address belongs to a valid constrained LR/SC loop (where probes must be rejected).

When scanning bne t0, a1, 2b in this scenario, should the scanner treat this as an invalid sequence and stop, or should it ignore this branch target and continue scanning forward?

[1]
https://docs.riscv.org/reference/isa/v20260120/unpriv/a-st-ext.html#sec:lrscseq

Thanks,

Vladimir