cpufreq: tegra186: add OPP support and set bandwidth

bug report Dan Carpenter 2 participants 3 messages Oct 24, 2025 – Oct 27, 2025 Tegra architecture support

lore
Share & tools
lore
#0 lore raw

Hello Aaron Kling,

Commit 71c46a6457e0 ("cpufreq: tegra186: add OPP support and set bandwidth") from Oct 21, 2025 (linux-next), leads to the following Smatch static checker warning:

	drivers/cpufreq/tegra186-cpufreq.c:197 tegra186_cpufreq_init()
	error: uninitialized symbol 'freq_table'.

drivers/cpufreq/tegra186-cpufreq.c

    174 static int tegra186_cpufreq_init(struct cpufreq_policy *policy)
    175 {
    176         struct tegra186_cpufreq_data *data = cpufreq_get_driver_data();
    177         unsigned int cluster = data->cpus[policy->cpu].bpmp_cluster_id;
    178         struct cpufreq_frequency_table *freq_table;
    179         struct cpufreq_frequency_table *bpmp_lut;
    180         u32 cpu;
    181         int ret;
    182 
    183         policy->cpuinfo.transition_latency = 300 * 1000;
    184         policy->driver_data = NULL;
    185 
    186         /* set same policy for all cpus in a cluster */
    187         for (cpu = 0; cpu < ARRAY_SIZE(tegra186_cpus); cpu++) {
    188                 if (data->cpus[cpu].bpmp_cluster_id == cluster)
    189                         cpumask_set_cpu(cpu, policy->cpus);
    190         }
    191 
    192         bpmp_lut = data->clusters[cluster].bpmp_lut;
    193 
    194         if (data->icc_dram_bw_scaling) {
    195                 ret = tegra_cpufreq_init_cpufreq_table(policy, bpmp_lut, &freq_table);
    196                 if (!ret) {

--> 197 policy->freq_table = freq_table;

tegra_cpufreq_init_cpufreq_table() will return zero if there are no available opps. The freq_table will be uninitialized in that case. It's this path:

          122          max_opps = dev_pm_opp_get_opp_count(cpu_dev);
          123          if (max_opps <= 0) {
          124                  dev_err(cpu_dev, "Failed to add OPPs\n");
          125                  return max_opps;
          126          }

    198                         return 0;
    199                 }
    200         }
    201 
    202         data->icc_dram_bw_scaling = false;
    203         policy->freq_table = bpmp_lut;
    204         pr_info("OPP tables missing from DT, EMC frequency scaling disabled\n");
    205 
    206         return 0;
    207 }

regards,
dan carpenter

#1 lore raw
Quoted 57 lines · Dan Carpenter

Hello Aaron Kling,

Commit 71c46a6457e0 ("cpufreq: tegra186: add OPP support and set bandwidth") from Oct 21, 2025 (linux-next), leads to the following Smatch static checker warning:

drivers/cpufreq/tegra186-cpufreq.c:197 tegra186_cpufreq_init()
error: uninitialized symbol 'freq_table'.

drivers/cpufreq/tegra186-cpufreq.c

    174 static int tegra186_cpufreq_init(struct cpufreq_policy *policy)
    175 {
    176         struct tegra186_cpufreq_data *data = cpufreq_get_driver_data();
    177         unsigned int cluster = data->cpus[policy->cpu].bpmp_cluster_id;
    178         struct cpufreq_frequency_table *freq_table;
    179         struct cpufreq_frequency_table *bpmp_lut;
    180         u32 cpu;
    181         int ret;
    182
    183         policy->cpuinfo.transition_latency = 300 * 1000;
    184         policy->driver_data = NULL;
    185
    186         /* set same policy for all cpus in a cluster */
    187         for (cpu = 0; cpu < ARRAY_SIZE(tegra186_cpus); cpu++) {
    188                 if (data->cpus[cpu].bpmp_cluster_id == cluster)
    189                         cpumask_set_cpu(cpu, policy->cpus);
    190         }
    191
    192         bpmp_lut = data->clusters[cluster].bpmp_lut;
    193
    194         if (data->icc_dram_bw_scaling) {
    195                 ret = tegra_cpufreq_init_cpufreq_table(policy, bpmp_lut, &freq_table);
    196                 if (!ret) {

--> 197 policy->freq_table = freq_table;

tegra_cpufreq_init_cpufreq_table() will return zero if there are no available opps. The freq_table will be uninitialized in that case. It's this path:

          122          max_opps = dev_pm_opp_get_opp_count(cpu_dev);
          123          if (max_opps <= 0) {
          124                  dev_err(cpu_dev, "Failed to add OPPs\n");
          125                  return max_opps;
          126          }

    198                         return 0;
    199                 }
    200         }
    201
    202         data->icc_dram_bw_scaling = false;
    203         policy->freq_table = bpmp_lut;
    204         pr_info("OPP tables missing from DT, EMC frequency scaling disabled\n");
    205
    206         return 0;
    207 }
Quoted 2 lines

regards,
dan carpenter

I'm looking at dev_pm_opp_of_add_table_indexed which gets called before dev_pm_opp_get_opp_count inside tegra_cpufreq_init_cpufreq_table(). It states that it will return -ENODATA if the opp table is empty, which would then return a negative value from tegra_cpufreq_init_cpufreq_table(), which gets handled as expected. Is there a way for opp count to be zero that would get past this? The code could be better, but I'm not sure there's an operable fail case here.

Also of note, the same effective flow exists in the tegra194 cpufreq driver, so if something does need to be fixed here, it should probably be applied there at the same time.

Sincerely,
Aaron

#2 lore raw
Quoted 58 lines · Aaron Kling
Quoted 57 lines · Dan Carpenter

Hello Aaron Kling,

Commit 71c46a6457e0 ("cpufreq: tegra186: add OPP support and set bandwidth") from Oct 21, 2025 (linux-next), leads to the following Smatch static checker warning:

drivers/cpufreq/tegra186-cpufreq.c:197 tegra186_cpufreq_init()
error: uninitialized symbol 'freq_table'.

drivers/cpufreq/tegra186-cpufreq.c

    174 static int tegra186_cpufreq_init(struct cpufreq_policy *policy)
    175 {
    176         struct tegra186_cpufreq_data *data = cpufreq_get_driver_data();
    177         unsigned int cluster = data->cpus[policy->cpu].bpmp_cluster_id;
    178         struct cpufreq_frequency_table *freq_table;
    179         struct cpufreq_frequency_table *bpmp_lut;
    180         u32 cpu;
    181         int ret;
    182
    183         policy->cpuinfo.transition_latency = 300 * 1000;
    184         policy->driver_data = NULL;
    185
    186         /* set same policy for all cpus in a cluster */
    187         for (cpu = 0; cpu < ARRAY_SIZE(tegra186_cpus); cpu++) {
    188                 if (data->cpus[cpu].bpmp_cluster_id == cluster)
    189                         cpumask_set_cpu(cpu, policy->cpus);
    190         }
    191
    192         bpmp_lut = data->clusters[cluster].bpmp_lut;
    193
    194         if (data->icc_dram_bw_scaling) {
    195                 ret = tegra_cpufreq_init_cpufreq_table(policy, bpmp_lut, &freq_table);
    196                 if (!ret) {

--> 197 policy->freq_table = freq_table;

tegra_cpufreq_init_cpufreq_table() will return zero if there are no available opps. The freq_table will be uninitialized in that case. It's this path:

          122          max_opps = dev_pm_opp_get_opp_count(cpu_dev);
          123          if (max_opps <= 0) {
          124                  dev_err(cpu_dev, "Failed to add OPPs\n");
          125                  return max_opps;
          126          }

    198                         return 0;
    199                 }
    200         }
    201
    202         data->icc_dram_bw_scaling = false;
    203         policy->freq_table = bpmp_lut;
    204         pr_info("OPP tables missing from DT, EMC frequency scaling disabled\n");
    205
    206         return 0;
    207 }
Quoted 7 lines
Quoted 2 lines

regards,
dan carpenter

I'm looking at dev_pm_opp_of_add_table_indexed which gets called before dev_pm_opp_get_opp_count inside tegra_cpufreq_init_cpufreq_table(). It states that it will return -ENODATA if the opp table is empty,

I don't see the comment you're referring to but the call to dev_pm_opp_get_opp_count() which comes next would prevent an empty table. So it's fine. We can leave this as-is. Thanks for reviewing it.

regards,
dan carpenter