board: siemens: iot2050: Fix logical bug in PG1/PG2 detection
PATCH 1/1 board: siemens: iot2050: Fix logical bug in PG1/PG2 detection
From: Jan Kiszka <[email protected]>
This caused the wrong fdtfile to be set and was failing to apply M.2 settings.
Fixes badaa1f6a7a9 ("boards: siemens: iot2050: Unify PG1 and PG2/M.2 configurations again")
Signed-off-by Jan Kiszka <[email protected]>
--- board/siemens/iot2050/board.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
board/siemens/iot2050/board.c +1 -1
@@ -160,7 +160,7 @@ static bool board_is_sr1(void)struct iot2050_info *info =IOT2050_INFO_DATA ;return info->magic ==IOT2050_INFO_MAGIC && -strstr ((char *)info->name,"-PG2" ) !=NULL ; +strstr ((char *)info->name,"-PG2" ) ==NULL ; }static bool board_is_m2 (void )
Signature · 1 line
2.35.3
Quoted 7 lines · Jan Kiszka
From: Jan Kiszka <[email protected]>
This caused the wrong fdtfile to be set and was failing to apply M.2 settings.
Fixes badaa1f6a7a9 ("boards: siemens: iot2050: Unify PG1 and PG2/M.2 configurations again")Signed-off-by Jan Kiszka <[email protected]>
Applied to u-boot/master, thanks!
Signature · 1 line