I am working to reduce the time window when the BMC offers a default password to its network users.  See the [expired password design][].  The idea is to force users to change the BMC's password as soon as possible.

[expired password design]: https://gerrit.openbmc-project.xyz/c/openbmc/docs/+/23849

Note: This design seeks to reduce the time window when the BMC is on the network with a default password, not to completely remove this vulnerability.  The time window begins when the system is plugged into power, and ends when the BMC's password is changed.

When complete, I believe this will offer significant protection for the BMC and can be used to help comply with laws such as CA Law [SB-327][], specifically section 1798.91.04 (b) (2) which states "The device contains a security feature that requires a user to generate a new means of authentication before access is granted to the device for the first time."  Where "the device" is the BMC, and "access" means access past the BMC's authentication mechanism to a session which can operate the BMC's controls.  The section cited above seems to accept the time window as a reasonable security exposure and to use the term "access" as I have done.

[SB-327]: https://leginfo.legislature.ca.gov/faces/billTextClient.xhtml?bill_id=201720180SB327

HOWEVER, there is a hole in this design which extends the time window indefinitely.  The scenario begins when the installer takes possession of a new system (BMC + host) and plugs it into power.  At this point, the BMC starts running and offering its services to network users.  The host remains powered off.  The installer then disregards the BMC and uses the power button to boot the host system, then continues to disregard the BMC when provisioning the host, either using physical access to the host (not via the BMC), or a pre-configured host.  This results in a fully-functional host and a BMC which still has its default password.

THEREFORE, I am proposing a new "disabled power button" image feature.  Normally, pressing the power button tells the BMC to power on and boot the host.  With this design, if the BMC still has its default expired password, it will ignore a power button press, and will instead indicate to the operator to configure the BMC's password, and try again.  Options for the BMC to indicate this are machine-specific and include: messages to an operator panel, or LED blink codes.  The recovery procedure is for the installer to access the BMC, change its password, and try again to power on the server.

The implementation might possibly be in the [state manager][] so it can perform this check if the server is powered on for any reason. The test if the BMC still has its default expired password could be performed by invoking Linux PAM APIs, effectively trying to authenticate using the default credentials, and checking if the credentials and valid and expired.  An alternate approach could instead check if the BMC is in provisioning mode.

[state manager]: https://github.com/openbmc/phosphor-state-manager

Note: The "disabled power button" design feature would be off default.  Platforms wanting to use it would have enable the image feature.

- Joseph

#1 lore raw
Quoted 11 lines · Joseph Reynolds

HOWEVER, there is a hole in this design which extends the time window indefinitely.  The scenario begins when the installer takes possession of a new system (BMC + host) and plugs it into power.  At this point, the BMC starts running and offering its services to network users. The host remains powered off.  The installer then disregards the BMC and uses the power button to boot the host system, then continues to disregard the BMC when provisioning the host, either using physical access to the host (not via the BMC), or a pre-configured host.  This results in a fully-functional host and a BMC which still has its default password.
THEREFORE, I am proposing a new "disabled power button" image

Quoted 9 lines

feature.  Normally, pressing the power button tells the BMC to power on and boot the host.  With this design, if the BMC still has its default expired password, it will ignore a power button press, and will instead indicate to the operator to configure the BMC's password, and try again.  Options for the BMC to indicate this are machine-specific and include: messages to an operator panel, or LED blink codes.  The recovery procedure is for the installer to access the BMC, change its password, and try again to power on the server.

This goes completely against one of the principals that some commercial products hold dear:  The BMC should NEVER be able to brick the host.

In a perfect world, the BMC would never crash, get loaded with bad firmware or brick itself.  In practice, this is far from the case.  In general the primary avenue used to resolve these cases is a force firmware update jumper, and a download of a new (fixed) firmware via KCS or block transfer.  For that flow to function, the power button needs to work, and the host needs to boot, otherwise the board is considered bricked, and needs to be returned to the factory to be reflashed.

With all of the above said, if it's an option that can be disabled (and hopefully disabled by default) I have no objection to it, but I don't think it's an acceptable solution for most of the BMCs out on the market today.

Another option for your scenario would also be to default the BMC to a static IP of 0.0.0.0, and disable the NIC(s) by default.  To set up the network, a user would need to log into the BMC the first time over an in-band channel, set their password, then set up either a valid static IP, or DHCP.  This is how some of the more security conscious BMCs I know of get around this problem today.

#2 lore raw
Quoted 38 lines · Ed Tanous
Quoted 11 lines · Joseph Reynolds

HOWEVER, there is a hole in this design which extends the time window indefinitely.  The scenario begins when the installer takes possession of a new system (BMC + host) and plugs it into power.  At this point, the BMC starts running and offering its services to network users. The host remains powered off.  The installer then disregards the BMC and uses the power button to boot the host system, then continues to disregard the BMC when provisioning the host, either using physical access to the host (not via the BMC), or a pre-configured host.  This results in a fully-functional host and a BMC which still has its default password.
THEREFORE, I am proposing a new "disabled power button" image

Quoted 9 lines

feature.  Normally, pressing the power button tells the BMC to power on and boot the host.  With this design, if the BMC still has its default expired password, it will ignore a power button press, and will instead indicate to the operator to configure the BMC's password, and try again.  Options for the BMC to indicate this are machine-specific and include: messages to an operator panel, or LED blink codes.  The recovery procedure is for the installer to access the BMC, change its password, and try again to power on the server.

This goes completely against one of the principals that some commercial products hold dear:  The BMC should NEVER be able to brick the host.

In a perfect world, the BMC would never crash, get loaded with bad firmware or brick itself.  In practice, this is far from the case.  In general the primary avenue used to resolve these cases is a force firmware update jumper, and a download of a new (fixed) firmware via KCS or block transfer.  For that flow to function, the power button needs to work, and the host needs to boot, otherwise the board is considered bricked, and needs to be returned to the factory to be reflashed.

With all of the above said, if it's an option that can be disabled (and hopefully disabled by default) I have no objection to it, but I don't think it's an acceptable solution for most of the BMCs out on the market today.

Quoted 6 lines

Another option for your scenario would also be to default the BMC to a static IP of 0.0.0.0, and disable the NIC(s) by default.  To set up the network, a user would need to log into the BMC the first time over an in-band channel, set their password, then set up either a valid static IP, or DHCP.  This is how some of the more security conscious BMCs I know of get around this problem today.

Thanks for your reply.  That helps.  We also don't want to brick our systems. :-)

How likely is the scenario described in the HOWEVER clause above? To create this security exposure, the installer would have to connect a network cable to the BMC and then not access the BMC via its network connection.  Is that something that happens in practice?  Could this be mitigated by installation instructions? The installation instructions could state, for example, not to connect a network cable to the BMC unless you then change the BMC's default password.  Then to emphasize the point, the instructions could also state, for example, that you must change the BMC's default password if you connect a network cable to it.

However, this approach doesn't feel secure by default.  I understand the more general problem is how to securely provision your BMC. Does anyone know where these discussions are happening?

- Joseph

#3 lore raw

Hi Joseph,

Not sure if this info helps much.. But, I know we did provision the FSP on the SoftLayer environment which had constraints. Possibly we can look into how that was done ?

!! Vishwa !!

Quoted 56 lines · Joseph Reynolds
Quoted 38 lines · Ed Tanous
Quoted 11 lines · Joseph Reynolds

HOWEVER, there is a hole in this design which extends the time window indefinitely.  The scenario begins when the installer takes possession of a new system (BMC + host) and plugs it into power.  At this point, the BMC starts running and offering its services to network users. The host remains powered off.  The installer then disregards the BMC and uses the power button to boot the host system, then continues to disregard the BMC when provisioning the host, either using physical access to the host (not via the BMC), or a pre-configured host.  This results in a fully-functional host and a BMC which still has its default password.
THEREFORE, I am proposing a new "disabled power button" image

Quoted 9 lines

feature.  Normally, pressing the power button tells the BMC to power on and boot the host.  With this design, if the BMC still has its default expired password, it will ignore a power button press, and will instead indicate to the operator to configure the BMC's password, and try again.  Options for the BMC to indicate this are machine-specific and include: messages to an operator panel, or LED blink codes.  The recovery procedure is for the installer to access the BMC, change its password, and try again to power on the server.

This goes completely against one of the principals that some commercial products hold dear:  The BMC should NEVER be able to brick the host.

In a perfect world, the BMC would never crash, get loaded with bad firmware or brick itself.  In practice, this is far from the case.  In general the primary avenue used to resolve these cases is a force firmware update jumper, and a download of a new (fixed) firmware via KCS or block transfer.  For that flow to function, the power button needs to work, and the host needs to boot, otherwise the board is considered bricked, and needs to be returned to the factory to be reflashed.

With all of the above said, if it's an option that can be disabled (and hopefully disabled by default) I have no objection to it, but I don't think it's an acceptable solution for most of the BMCs out on the market today.

Quoted 6 lines

Another option for your scenario would also be to default the BMC to a static IP of 0.0.0.0, and disable the NIC(s) by default.  To set up the network, a user would need to log into the BMC the first time over an in-band channel, set their password, then set up either a valid static IP, or DHCP.  This is how some of the more security conscious BMCs I know of get around this problem today.

Thanks for your reply.  That helps.  We also don't want to brick our systems. :-)

How likely is the scenario described in the HOWEVER clause above? To create this security exposure, the installer would have to connect a network cable to the BMC and then not access the BMC via its network connection.  Is that something that happens in practice?  Could this be mitigated by installation instructions? The installation instructions could state, for example, not to connect a network cable to the BMC unless you then change the BMC's default password.  Then to emphasize the point, the instructions could also state, for example, that you must change the BMC's default password if you connect a network cable to it.

However, this approach doesn't feel secure by default.  I understand the more general problem is how to securely provision your BMC. Does anyone know where these discussions are happening?

- Joseph