Skip to contentSkip to conversation

Questions on mmc_test suite

DISCUSSION Martin Fuzzey 2 participants 2 messages Apr 15, 2009 – Apr 25, 2009

lore
Share & tools
lore
#0 lore raw

Hi,
I'm currently updating the mxcmmc driver for the i.MX21 platform [patches have been posted to the arm list] and have a couple of questions about the test suite.

1) I'm getting an error on testcase 10 (weird reads) which does reads of 3 to 512 bytes by steps of 7.
Modifying the test so it continues in case of error shows that it _only_ fails on the 395 byte read.

It fails with a software timeout (-110)
The card sends the same response to CMD17 (READ_SINGLE_BLOCK) as the reads that work
but hardware never indicates transfer complete.

Changing the test to start at 395 makes it fail immediately (so not dependent on previous reads).
Has anyone seen this before?

2) I'm getting "Warning: Host did not wait for busy state to end" on the multiblock write tests (Tests 5 and 13) but they still pass. Seems to be timing related since this doesn't occur with MMC debugging enabled. My understanding of this is that the driver should wait for the hardware to stop signalling busy on the data line (response R1b) after sending
command 12 (stop transmission) before replying - is this correct? However the MX2 SDHC doesn't have a register for this.

Should I:
a) ignore it? [apart from the testcase warning everything seems to work]
b) try reading the data line as GPIO - seems a bit of a hack
c) issue CMD13 (SEND_STATUS) from the driver to poll the card - seems to be the wrong layer.

If b) is the way to go how long can the delay be - is polling acceptable or must it be interrupt driven?

Regards,

Martin

#1 lore raw
Quoted 10 lines · On Wed, 15 Apr 2009 11:13:44 +0200 Martin Fuzzey <[email protected]> wrote:

Hi,
I'm currently updating the mxcmmc driver for the i.MX21 platform [patches have been posted to the arm list] and have a couple of questions about the test suite.

1) I'm getting an error on testcase 10 (weird reads) which does reads of 3 to 512 bytes by steps of 7.
Modifying the test so it continues in case of error shows that it _only_ fails on the 395 byte read.

Quoted 9 lines

It fails with a software timeout (-110)
The card sends the same response to CMD17 (READ_SINGLE_BLOCK) as the reads that work
but hardware never indicates transfer complete.

Changing the test to start at 395 makes it fail immediately (so not dependent on previous reads).
Has anyone seen this before?

Nothing I recognize, no. Have you tested more than one card in case it's a card bug?

Quoted 9 lines

2) I'm getting "Warning: Host did not wait for busy state to end" on the multiblock write tests (Tests 5 and 13) but they still pass. Seems to be timing related since this doesn't occur with MMC debugging enabled. My understanding of this is that the driver should wait for the hardware to stop signalling busy on the data line (response R1b) after sending
command 12 (stop transmission) before replying - is this correct? However the MX2 SDHC doesn't have a register for this.

Quoted 9 lines

Should I:
a) ignore it? [apart from the testcase warning everything seems to work]
b) try reading the data line as GPIO - seems a bit of a hack
c) issue CMD13 (SEND_STATUS) from the driver to poll the card - seems to be the wrong layer.

If b) is the way to go how long can the delay be - is polling acceptable or must it be interrupt driven?

I'd say a). If the hardware doesn't support it then I don't think we can do that much better than the polling that mmc_block does.

Rgds

Signature · 6 lines
     -- Pierre Ossman

  WARNING: This correspondence is being monitored by the
  Swedish government. Make sure your server uses encryption
  for SMTP traffic and consider using PGP for end-to-end
  encryption.