Skip to contentSkip to conversation

New: Power-On-Reset Prevents Successful Receive Diagnostics Command in SES Module.

Bug 205461 [email protected] 1 participant 2 messages Nov 7, 2019 SCSI

lore
Share & tools
lore
#0 lore raw

https://bugzilla.kernel.org/show_bug.cgi?id=205461

Bug ID: 205461
Summary: Power-On-Reset Prevents Successful Receive Diagnostics
Command in SES Module.
Product: SCSI Drivers
Version: 2.5
Kernel Version: 5.4-rc6
Hardware: All
OS: Linux
Tree: Mainline
Status: NEW
Severity: normal
Priority: P1
Component: Other
Assignee: [email protected]
Reporter: [email protected]
Regression: No

Created attachment 285817
--> https://bugzilla.kernel.org/attachment.cgi?id=285817&action=edit
Power-On-Reset Prevents Successful Receive Diagnostics Command

Overview:

When booting an SES device connected to an ATTO SAS HBA, the SES module issues a 'Receive Diagnostics' command that fails with check condition power-on-reset and is not retried by the SES module.

Interestingly, when booting an SES device connected to an LSI SAS HBA, the Receive Diagnostics succeeds due to LSI issuing a 'Mode Sense' command prior to the SES module sending the 'Receive Diagnostics' that clears the check condition power-on-reset.

Us (ATTO) does not want to have to issue a command to clear the check condition power-on-reset unless we must. There is no spec that states this is what must happen and seems to be a case that the SES module should handle.

Steps to Reproduce:

With an ATTO SAS HBA:
Connect an SES device to an ATTO SAS HBA, then power on the SES device.

With an LSI SAS HBA:
I was able to reproduce this issue with an LSI SAS HBA and other SAS HBAs by unloading the SES module, issuing a target reset to the SES device, then re-loading the SES module.

Actual Results:

In the system log you will see

[  953.809858] scsi 7:0:0:0: Power-on or device reset occurred
[  953.809891] scsi 7:0:0:0: Failed to get diagnostic page 0x1
[  953.809931] scsi 7:0:0:0: Failed to bind enclosure -19

This can also be observed in the "sas_poweron_atto.scs" SAS trace.

Expected Results:

The Receive Diagnostics command to succeed and no error logged to the system log.

This can also be observed in a SAS trace of an SES device connected to an LSI HBA, where the 'Receive Diagnostics' command succeeds due to the check condition power-on-reset being cleared by the 'Mode Sense' command issued prior to the 'Receive Diagnostics'. (Trace can be provided upon request).

Additional Information:

It appears that I cannot attach SAS traces from both ATTO and LSI devices, so I have attached the trace while connected to an ATTO SAS HBA that clearly exhibits the error. If both traces are needed, I can provide them by a different means.

Signature · 2 lines
You are receiving this mail because:
You are watching the assignee of the bug.
#1 lore raw

[Bug 205461] Power-On-Reset Prevents Successful Receive Diagnostics Command in SES Module.

https://bugzilla.kernel.org/show_bug.cgi?id=205461

Steven Siwinski ([email protected]) changed:

What |Removed |Added
----------------------------------------------------------------------------
CC| |[email protected]

--- Comment #1 from Steven Siwinski ([email protected]) --- Created attachment 285819
--> https://bugzilla.kernel.org/attachment.cgi?id=285819&action=edit
SAS trace of AVAGO HBA that issues 'mode sense' prior to SES sending 'Receive Diagnostics'

Signature · 2 lines
You are receiving this mail because: