            Bug ID: 450
           Summary: wrong report for cycles/pkt or pps
           Product: DPDK
           Version: 20.02
          Hardware: ARM
                OS: All
            Status: UNCONFIRMED
          Severity: normal
          Priority: Normal
         Component: testpmd
          Assignee: [email protected]
          Reporter: [email protected]

Target Milestone: ---

According to doc/guides/prog_guide/profile_app.rst RTE_ARM_EAL_RDTSC_USE_PMU has to be used over ARM CPU to get correct cyc/pkt report. This involves using OOT (non upstream) kernel module which is problematic and reported to be non-stable.

Moreover, once the PMU configuration is set, the pps report done by testpmd is wrong, so this doesn't really help, as one wants to see both pps and cyc/pkt.

If the PMU configuration is not set, indeed the cyc/pkt report is wrong, but this is due to using a timer which is not running in the CPU frequency. If the CPU frequency would be used we can get a correct cyc/pkt report without the PMU config.