New: Support for LSI Logic / Symbios Logic M1064E MegaRAID SAS

Bug 61771 [email protected] 1 participant 6 messages Sep 21, 2013 – May 16, 2014 SCSI

lore
Share & tools
lore
#0 lore raw

https://bugzilla.kernel.org/show_bug.cgi?id=61771

            Bug ID: 61771
           Summary: Support for LSI Logic / Symbios Logic M1064E MegaRAID
                    SAS
           Product: SCSI Drivers
           Version: 2.5
    Kernel Version: 3.8.13-gentoo
          Hardware: All
                OS: Linux
              Tree: Mainline
            Status: NEW
          Severity: normal
          Priority: P1
         Component: Other
          Assignee: [email protected]
          Reporter: [email protected]
        Regression: No

Created attachment 109031
--> https://bugzilla.kernel.org/attachment.cgi?id=109031&action=edit
Informations of hardware.

Requesting support for M1064E MegaRAID SAS support.

Informations attached

Signature · 2 lines
You are receiving this mail because:
You are watching the assignee of the bug.
#1 lore raw

[Bug 61771] Support for LSI Logic / Symbios Logic M1064E MegaRAID SAS

https://bugzilla.kernel.org/show_bug.cgi?id=61771

Adam Radford <[email protected]> changed:

What |Removed |Added
----------------------------------------------------------------------------
CC| |[email protected]

--- Comment #1 from Adam Radford <[email protected]> ---
04:00.0 SCSI storage controller: LSI Logic / Symbios Logic M1064E MegaRAID SAS (rev 04)
04:00.0 0100: 1000:0057 (rev 04)

LSI MegaRAID device id 0x57 is really an old "software raid" embedded solution.

Support for this device existed in a closed source driver called "megasr", and will not be added to the open source megaraid_sas drivers.

-Adam Radford @ LSI

Signature · 2 lines
You are receiving this mail because:
You are watching the assignee of the bug.
#2 lore raw

[Bug 61771] Support for LSI Logic / Symbios Logic M1064E MegaRAID SAS

In reply to [email protected]

https://bugzilla.kernel.org/show_bug.cgi?id=61771

--- Comment #2 from Leonardo Amaral <[email protected]> --- Adam, my board is a S5000XVN and supports AXXRAKSW5 for RAID5 and im worried about the expansibility of this board. Will this megasr support or some another module support?

Also, the closed-source megasr will compile in Kernel 3.11 and forward?

Signature · 2 lines
You are receiving this mail because:
You are watching the assignee of the bug.
#3 lore raw

[Bug 61771] Support for LSI Logic / Symbios Logic M1064E MegaRAID SAS

In reply to [email protected]

https://bugzilla.kernel.org/show_bug.cgi?id=61771

Alan <[email protected]> changed:

What |Removed |Added
----------------------------------------------------------------------------

             Status|NEW                         |RESOLVED
                 CC|                            |[email protected]
         Resolution|---                         |WILL_NOT_FIX
Signature · 2 lines
You are receiving this mail because:
You are watching the assignee of the bug.
#5 lore raw

[Bug 61771] Support for LSI Logic / Symbios Logic M1064E MegaRAID SAS

In reply to [email protected]

https://bugzilla.kernel.org/show_bug.cgi?id=61771

Azamat H. Hackimov <[email protected]> changed:

What |Removed |Added
----------------------------------------------------------------------------
CC| |[email protected]

--- Comment #3 from Azamat H. Hackimov <[email protected]> --- Hello.
There one trick with mptsas driver from recent kernel. Since this is unofficial, there NO WARRANTY big warning. I not checked for already existing RAID with data only on just created RAID. Before any actions on actual data perform backup first!

Turns out, some LSI / Symbios Logic fakeraid cards can be recognized my mptsas with additional pciids. All you need is find pciids for you card. My card is

lspci -nn | grep LSI
08:00.0 SCSI storage controller [0100]: LSI Logic / Symbios Logic M1064E MegaRAID SAS [1000:0057] (rev 04)

Where [1000:0057] is PCI ID. Next you need do follow:

echo "1000 0057" > /sys/bus/pci/drivers/mptsas/new_id

Add this row to /etc/rc.conf or somewhere else for applying to next boot.

If all goes right, you physical disks will be appear in system (check dmesg). For RAID capabilities you need to install mdadm. It autodetects partitions as /dev/mdX:

# cat /proc/mdstat
Personalities : [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4]
[raid10]
md126 : active raid1 sde[1] sdd[0]
      142577664 blocks super external:/md127/0 [2/2] [UU]
      [=======>.............]  resync = 39.3% (56174464/142577664)
finish=1351.1min speed=1065K/sec
Signature · 2 lines
You are receiving this mail because:
You are watching the assignee of the bug.