thermal: cpu_cooling: Fixes and cleanups
cover thermal: cpu_cooling: Fixes and cleanups
Hi Eduardo,
As you know I got into fixing cpu_cooling.c due to some cpufreq issues you and Lukasz were struggling with. I found some issues in cpu_cooling then and here are the fixes/cleanups.
Sorry for the long list. Haven't broken them into smaller sets as most of the patches are very small, easy to review and inter-dependent. Only few of them should take more time to review. If this doesn't work out, let me know and I will try to send separate inter-dependent sets.
Just apply whatever looks fine and I will update/resend the ones left in V2 if at required.
First few are updates to platform drivers. Exynos fails to register after few patches in this series as it doesn't handle -EPROBE_DEFER properly (reported that in reply to your patch as well). Others weren't setting clip_cpus properly and are fixed.
Next ones are cleanups of cpu_cooling.c to get things properly organized.
Let me know if I screwed it up completely.
Tested-on: Exynos5250 (Dual ARM Cortex A15).
Rebased-over: v3.18-rc6
Pushed here: git://git.kernel.org/pub/scm/linux/kernel/git/vireshk/linux.git
thermal/cpu-cooling-fixes
Viresh Kumar (26):
thermal: db8500: pass cpu_present_mask to cpufreq_cooling_register()
thermal: imx: pass cpu_present_mask to cpufreq_cooling_register()
thermal: exynos: pass cpu_present_mask to cpufreq_cooling_register()
thermal: exynos: Handle -EPROBE_DEFER properly
cpu_cooling: random comment fixups
cpu_cooling: fix doc comment over struct cpufreq_cooling_device
cpu_cooling: Add comment to clarify relation between cooling state and
frequency
cpu_cooling: Pass variable instead of its type to sizeof()
cpu_cooling: no need to set cpufreq_state to zero
cpu_cooling: no need to set cpufreq_dev to NULL
cpu_cooling: propagate error returned by idr_alloc()
cpu_cooling: Don't match min/max frequencies for all CPUs on cooling
register
cpu_cooling: don't iterate over all allowed_cpus to update cpufreq
policy
cpu_cooling: Don't check is_cpufreq_valid()
cpu_cooling: do error handling at the bottom in
__cpufreq_cooling_register()
cpu_cooling: Drop useless locking around idr_alloc/idr_remove
cpu_cooling: Merge cpufreq_apply_cooling() into
cpufreq_set_cur_state()
cpu_cooling: Merge get_cpu_frequency() into cpufreq_set_cur_state()
cpu_cooling: find max level during device registration
cpu_cooling: get_property() doesn't need to support GET_MAXL anymore
cpu_cooling: create list of cpufreq_cooling_devices
cpu_cooling: use cpufreq_dev_list instead of cpufreq_dev_count
cpu_cooling: Pass 'cpufreq_dev' to get_property()
cpu_cooling: Store frequencies in descending order
cpu_cooling: Use cpufreq_dev->freq_table for finding level/freq
cpu_cooling: update copyright tags
drivers/thermal/cpu_cooling.c | 405 +++++++++--------------- drivers/thermal/db8500_cpufreq_cooling.c | 5 +- drivers/thermal/imx_thermal.c | 4 +- drivers/thermal/samsung/exynos_thermal_common.c | 11 +- drivers/thermal/samsung/exynos_tmu.c | 4 +- 5 files changed, 153 insertions(+), 276 deletions(-)
Signature · 1 line
2.0.3.693.g996b0fd
PATCH 1/26 thermal: db8500: pass cpu_present_mask to cpufreq_cooling_register()
cpufreq_cooling_register() expects mask of all the CPUs where frequency constraint is applicable.
This platform has more than one CPU to which these constraints will apply and so passing mask of only CPU0 wouldn't be sufficient. Also, this platform has a single cluster of CPUs and the constraint applies to all CPUs.
If CPU0 is hoplugged out then we may face strange BUGs as cpu_cooling framework isn't aware of any siblings sharing clock line.
Fix it by passing cpu_present_mask to cpufreq_cooling_register().
--- drivers/thermal/db8500_cpufreq_cooling.c | 5 +---- 1 file changed, 1 insertion(+), 4 deletions(-)
drivers/thermal/db8500_cpufreq_cooling.c +1 -4
@@ -28,15 +28,12 @@static int db8500_cpufreq_cooling_probe (struct platform_device *pdev) {struct thermal_cooling_device *cdev; -struct cpumask mask_val;/* make sure cpufreq driver has been initialized */ if (!cpufreq_frequency_get_table (0 ))return -EPROBE_DEFER ; -cpumask_set_cpu (0 , &mask_val); - cdev =cpufreq_cooling_register (&mask_val); - + cdev =cpufreq_cooling_register (cpu_present_mask);if (IS_ERR (cdev)) {dev_err (&pdev->dev,"Failed to register cooling device\n" );return PTR_ERR (cdev);
Signature · 1 line
2.0.3.693.g996b0fd
PATCH 2/26 thermal: imx: pass cpu_present_mask to cpufreq_cooling_register()
In reply to Viresh Kumarcpufreq_cooling_register() expects mask of all the CPUs where frequency constraint is applicable.
This platform has more than one CPU to which these constraints will apply and so passing mask of only CPU0 wouldn't be sufficient. Also, this platform has a single cluster of CPUs and the constraint applies to all CPUs.
If CPU0 is hoplugged out then we may face strange BUGs as cpu_cooling framework isn't aware of any siblings sharing clock line.
Fix it by passing cpu_present_mask to cpufreq_cooling_register().
--- drivers/thermal/imx_thermal.c | 4 +--- 1 file changed, 1 insertion(+), 3 deletions(-)
drivers/thermal/imx_thermal.c +1 -3
@@ -454,7 +454,6 @@ static int imx_thermal_probe(struct platform_device *pdev)const struct of_device_id *of_id =of_match_device (of_imx_thermal_match, &pdev->dev);struct imx_thermal_data *data; -struct cpumask clip_cpus;struct regmap *map;int measure_freq;int ret;
@@ -516,8 +515,7 @@ static int imx_thermal_probe(struct platform_device *pdev)regmap_write (map,MISC0 +REG_SET ,MISC0_REFTOP_SELBIASOFF );regmap_write (map,TEMPSENSE0 +REG_SET ,TEMPSENSE0_POWER_DOWN ); -cpumask_set_cpu (0 , &clip_cpus); - data->cdev =cpufreq_cooling_register (&clip_cpus); + data->cdev =cpufreq_cooling_register (cpu_present_mask);if (IS_ERR (data->cdev)) { ret =PTR_ERR (data->cdev); dev_err(&pdev->dev,
Signature · 1 line
2.0.3.693.g996b0fd
PATCH 3/26 thermal: exynos: pass cpu_present_mask to cpufreq_cooling_register()
In reply to Viresh Kumarcpufreq_cooling_register() expects mask of all the CPUs where frequency constraint is applicable.
This platform has more than one CPU to which these constraints will apply and so passing mask of only CPU0 wouldn't be sufficient. Also, this platform has a single cluster of CPUs and the constraint applies to all CPUs.
If CPU0 is hoplugged out then we may face strange BUGs as cpu_cooling framework isn't aware of any siblings sharing clock line.
Fix it by passing cpu_present_mask to cpufreq_cooling_register().
--- drivers/thermal/samsung/exynos_thermal_common.c | 4 +--- 1 file changed, 1 insertion(+), 3 deletions(-)
drivers/thermal/samsung/exynos_thermal_common.c +1 -3
@@ -347,7 +347,6 @@ void exynos_report_trigger(struct thermal_sensor_conf *conf)int exynos_register_thermal (struct thermal_sensor_conf *sensor_conf) {int ret; -struct cpumask mask_val;struct exynos_thermal_zone *th_zone;if (!sensor_conf || !sensor_conf->read_temperature) {
@@ -367,9 +366,8 @@ int exynos_register_thermal(struct thermal_sensor_conf *sensor_conf)* sensor */ if (sensor_conf->cooling_data.freq_clip_count >0 ) { -cpumask_set_cpu (0 , &mask_val); th_zone->cool_dev[th_zone->cool_dev_size] = -cpufreq_cooling_register (&mask_val); +cpufreq_cooling_register (cpu_present_mask);if (IS_ERR (th_zone->cool_dev[th_zone->cool_dev_size])) {dev_err (sensor_conf->dev,"Failed to register cpufreq cooling device\n" );
Signature · 1 line
2.0.3.693.g996b0fd
PATCH 4/26 thermal: exynos: Handle -EPROBE_DEFER properly
In reply to Viresh Kumarcpufreq_cooling_register() can return -EPROBE_DEFER if cpufreq driver isn't ready yet and so the callers must defer their initialization.
Exynos thermal drivers weren't handling this well and were raising false error message when -EPROBE_DEFER is returned to them.
Fix them to handle -EPROBE_DEFER.
--- drivers/thermal/samsung/exynos_thermal_common.c | 7 ++++--- drivers/thermal/samsung/exynos_tmu.c | 4 +++- 2 files changed, 7 insertions(+), 4 deletions(-)
drivers/thermal/samsung/exynos_thermal_common.c +4 -3
@@ -369,9 +369,10 @@ int exynos_register_thermal(struct thermal_sensor_conf *sensor_conf) th_zone->cool_dev[th_zone->cool_dev_size] =cpufreq_cooling_register (cpu_present_mask);if (IS_ERR (th_zone->cool_dev[th_zone->cool_dev_size])) { -dev_err (sensor_conf->dev, -"Failed to register cpufreq cooling device\n" ); - ret = -EINVAL ; + ret =PTR_ERR (th_zone->cool_dev[th_zone->cool_dev_size]); +if (ret != -EPROBE_DEFER ) +dev_err (sensor_conf->dev, +"Failed to register cpufreq cooling device\n" ); goto err_unregister; } th_zone->cool_dev_size++;
drivers/thermal/samsung/exynos_tmu.c +3 -1
@@ -683,7 +683,9 @@ static int exynos_tmu_probe(struct platform_device *pdev)/* Register the sensor with thermal management interface */ ret =exynos_register_thermal (sensor_conf);if (ret) { -dev_err (&pdev->dev,"Failed to register thermal interface\n" ); +if (ret != -EPROBE_DEFER ) +dev_err (&pdev->dev, +"Failed to register thermal interface\n" ); goto err_clk; } data->reg_conf = sensor_conf;
Signature · 1 line
2.0.3.693.g996b0fd
Re: [PATCH 04/26] thermal: exynos: Handle -EPROBE_DEFER properly
Quoted 7 lines · Viresh Kumar
cpufreq_cooling_register()can return -EPROBE_DEFER if cpufreq driver isn't ready yet and so the callers must defer their initialization.Exynos thermal drivers weren't handling this well and were raising false error message when -EPROBE_DEFER is returned to them.
Fix them to handle -EPROBE_DEFER.
As mentioned in patch 0, this one has been merged to another patch.
Quoted 47 lines
Cc Chanwoo Choi <[email protected]>Cc Kyungmin Park <[email protected]>Cc Amit Daniel Kachhap <[email protected]>Cc Lukasz Majewski <[email protected]>Signed-off-by Viresh Kumar <[email protected]>--- drivers/thermal/samsung/exynos_thermal_common.c | 7 ++++--- drivers/thermal/samsung/exynos_tmu.c | 4 +++- 2 files changed, 7 insertions(+), 4 deletions(-)drivers/thermal/samsung/exynos_thermal_common.c +4
-3@@ -369,9 +369,10 @@ int exynos_register_thermal(struct thermal_sensor_conf *sensor_conf) th_zone->cool_dev[th_zone->cool_dev_size] =cpufreq_cooling_register (cpu_present_mask);if (IS_ERR (th_zone->cool_dev[th_zone->cool_dev_size])) { -dev_err (sensor_conf->dev, -"Failed to register cpufreq cooling device\n" ); - ret = -EINVAL ; + ret =PTR_ERR (th_zone->cool_dev[th_zone->cool_dev_size]); +if (ret != -EPROBE_DEFER ) +dev_err (sensor_conf->dev, +"Failed to register cpufreq cooling device\n" ); goto err_unregister; } th_zone->cool_dev_size++;drivers/thermal/samsung/exynos_tmu.c +3
-1@@ -683,7 +683,9 @@ static int exynos_tmu_probe(struct platform_device *pdev)/* Register the sensor with thermal management interface */ ret =exynos_register_thermal (sensor_conf);if (ret) { -dev_err (&pdev->dev,"Failed to register thermal interface\n" ); +if (ret != -EPROBE_DEFER ) +dev_err (&pdev->dev, +"Failed to register thermal interface\n" ); goto err_clk; } data->reg_conf = sensor_conf;Signature · 1 line
2.0.3.693.g996b0fd
PATCH 5/26 cpu_cooling: random comment fixups
In reply to Viresh Kumars/give/given
--- drivers/thermal/cpu_cooling.c | 5 +++-- 1 file changed, 3 insertions(+), 2 deletions(-)
drivers/thermal/cpu_cooling.c +3 -2
@@ -122,7 +122,7 @@ enum cpufreq_cooling_property { };/** -* get_property - fetch a property of interest for a give cpu. +* get_property - fetch a property of interest for a given cpu. * @cpu: cpu for which the property is required * @input: query parameter * @output: query return
@@ -132,6 +132,7 @@ enum cpufreq_cooling_property {* 1. get maximum cpu cooling states * 2. translate frequency to cooling state * 3. translate cooling state to frequency +* * Note that the code may be not in good shape * but it is written in this way in order to: * a) reduce duplicate code as most of the code can be shared.
@@ -212,7 +213,7 @@ static int get_property(unsigned int cpu, unsigned long input, }/** -* cpufreq_cooling_get_level - for a give cpu, return the cooling level. +* cpufreq_cooling_get_level - for a given cpu, return the cooling level. * @cpu: cpu for which the level is required * @freq: the frequency of interest *
Signature · 1 line
2.0.3.693.g996b0fd
Re: [PATCH 05/26] cpu_cooling: random comment fixups
Quoted 3 lines · Viresh Kumar
s/give/given
Signed-off-by Viresh Kumar <[email protected]>
Quoted 37 lines
--- drivers/thermal/cpu_cooling.c | 5 +++-- 1 file changed, 3 insertions(+), 2 deletions(-)drivers/thermal/cpu_cooling.c +3
-2@@ -122,7 +122,7 @@ enum cpufreq_cooling_property { };/** -* get_property - fetch a property of interest for a give cpu. +* get_property - fetch a property of interest for a given cpu. * @cpu: cpu for which the property is required * @input: query parameter * @output: query return @@ -132,6 +132,7 @@ enum cpufreq_cooling_property {* 1. get maximum cpu cooling states * 2. translate frequency to cooling state * 3. translate cooling state to frequency +* * Note that the code may be not in good shape * but it is written in this way in order to: * a) reduce duplicate code as most of the code can be shared. @@ -212,7 +213,7 @@ static int get_property(unsigned int cpu, unsigned long input, }/** -* cpufreq_cooling_get_level - for a give cpu, return the cooling level. +* cpufreq_cooling_get_level - for a given cpu, return the cooling level. * @cpu: cpu for which the level is required * @freq: the frequency of interest * Signature · 1 line
2.0.3.693.g996b0fd
PATCH 6/26 cpu_cooling: fix doc comment over struct cpufreq_cooling_device
In reply to Viresh Kumarcooling_cpufreq_lock isn't used to protect this structure and so the comment over it is outdated. Fix it.
--- drivers/thermal/cpu_cooling.c | 5 ++--- 1 file changed, 2 insertions(+), 3 deletions(-)
drivers/thermal/cpu_cooling.c +2 -3
@@ -40,9 +40,8 @@* frequency. * @allowed_cpus: all the cpus involved for this cpufreq_cooling_device. * -* This structure is required for keeping information of each -* cpufreq_cooling_device registered. In order to prevent corruption of this a -* mutex lock cooling_cpufreq_lock is used. +* This structure is required for keeping information of each registered +* cpufreq_cooling_device. */ struct cpufreq_cooling_device {int id;
Signature · 1 line
2.0.3.693.g996b0fd
PATCH 7/26 cpu_cooling: Add comment to clarify relation between cooling state and frequency
In reply to Viresh KumarThis wasn't explained well anywhere and should be clearly specified. Lets add a top level comment for this.
--- drivers/thermal/cpu_cooling.c | 14 ++++++++++++++ 1 file changed, 14 insertions(+)
drivers/thermal/cpu_cooling.c +14 -0
@@ -28,6 +28,20 @@#include <linux/cpu.h> #include <linux/cpu_cooling.h> +/* +* Cooling state <-> CPUFreq frequency +* +* Cooling states are translated to frequencies throughout this driver and this +* is the relation between them. +* +* Highest cooling state corresponds to lowest possible frequency. +* +* i.e. +* level 0 --> 1st Max Freq +* level 1 --> 2nd Max Freq +* ... +*/ +/** * struct cpufreq_cooling_device - data for cooling device with cpufreq * @id: unique integer value corresponding to each cpufreq_cooling_device
Signature · 1 line
2.0.3.693.g996b0fd
PATCH 8/26 cpu_cooling: Pass variable instead of its type to sizeof()
In reply to Viresh KumarJust following coding guidelines here.
--- drivers/thermal/cpu_cooling.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)
drivers/thermal/cpu_cooling.c +1 -2
@@ -468,8 +468,7 @@ __cpufreq_cooling_register(struct device_node *np,return ERR_PTR (-EINVAL ); } } - cpufreq_dev =kzalloc (sizeof (struct cpufreq_cooling_device ), -GFP_KERNEL ); + cpufreq_dev =kzalloc (sizeof (*cool_dev),GFP_KERNEL );if (!cpufreq_dev)return ERR_PTR (-ENOMEM );
Signature · 1 line
2.0.3.693.g996b0fd
Re: [PATCH 08/26] cpu_cooling: Pass variable instead of its type to sizeof()
Hi Viresh,
Quoted 12 lines · Viresh Kumar
Just following coding guidelines here.
Signed-off-by Viresh Kumar <[email protected]>--- drivers/thermal/cpu_cooling.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)drivers/thermal/cpu_cooling.c +0
-0
drivers/thermal/cpu_cooling.c __cpufreq_cooling_register(struct device_node *np, · line 471
Quoted 6 lines
drivers/thermal/cpu_cooling.c +1
-2@@ -468,8 +468,7 @@ __cpufreq_cooling_register(struct device_node *np,return ERR_PTR (-EINVAL ); } } - cpufreq_dev =kzalloc (sizeof (struct cpufreq_cooling_device ), -GFP_KERNEL ); + cpufreq_dev =kzalloc (sizeof (*cool_dev),GFP_KERNEL );
This should be:
+ cpufreq_dev = kzalloc(sizeof(*cpufreq_dev), GFP_KERNEL);
Cheers,
Javi
Re: [PATCH 08/26] cpu_cooling: Pass variable instead of its type to sizeof()
Hi,
Quoted 24 lines · Javi Merino
Hi Viresh,
Quoted 12 lines · Viresh Kumar
Just following coding guidelines here.
Signed-off-by Viresh Kumar <[email protected]>--- drivers/thermal/cpu_cooling.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)drivers/thermal/cpu_cooling.c +0
-0drivers/thermal/cpu_cooling.c __cpufreq_cooling_register(struct device_node *np, · line 471
Quoted 6 lines
drivers/thermal/cpu_cooling.c +1
-2@@ -468,8 +468,7 @@ __cpufreq_cooling_register(struct device_node *np,return ERR_PTR (-EINVAL ); } } - cpufreq_dev =kzalloc (sizeof (struct cpufreq_cooling_device ), -GFP_KERNEL ); + cpufreq_dev =kzalloc (sizeof (*cool_dev),GFP_KERNEL );This should be:
Review
Quoted 1 line
(quoted diff) +1
-0+ cpufreq_dev = kzalloc(sizeof(*cpufreq_dev), GFP_KERNEL);
Agreed.
Quoted 4 lines
Cheers,
Javi
Re: [PATCH 08/26] cpu_cooling: Pass variable instead of its type to sizeof()
Quoted 3 lines · Eduardo Valentin
Quoted 3 lines
This should be:
+
cpufreq_dev=kzalloc(sizeof(*cpufreq_dev), GFP_KERNEL);
This is insulting now. So stupid mistake..
PATCH 9/26 cpu_cooling: no need to set cpufreq_state to zero
In reply to Viresh KumarIts already zero, we allocated cpufreq_dev with kzalloc.
--- drivers/thermal/cpu_cooling.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/thermal/cpu_cooling.c +1 -1
@@ -491,7 +491,7 @@ __cpufreq_cooling_register(struct device_node *np,return cool_dev; } cpufreq_dev->cool_dev = cool_dev; - cpufreq_dev->cpufreq_state =0 ; +mutex_lock (&cooling_cpufreq_lock);/* Register the notifier for first cpufreq cooling device */
Signature · 1 line
2.0.3.693.g996b0fd
PATCH 10/26 cpu_cooling: no need to set cpufreq_dev to NULL
In reply to Viresh KumarIt will be overwritten soon with return value of kzalloc().
--- drivers/thermal/cpu_cooling.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/thermal/cpu_cooling.c +1 -1
@@ -448,7 +448,7 @@ __cpufreq_cooling_register(struct device_node *np, const struct cpumask *clip_cpus) {struct thermal_cooling_device *cool_dev; -struct cpufreq_cooling_device *cpufreq_dev =NULL ; +struct cpufreq_cooling_device *cpufreq_dev;unsigned int min =0 , max =0 ;char dev_name[THERMAL_NAME_LENGTH ];int ret =0 , i;
Signature · 1 line
2.0.3.693.g996b0fd
PATCH 11/26 cpu_cooling: propagate error returned by idr_alloc()
In reply to Viresh KumarWe aren't supposed to return our own error type here. Return what we got.
--- drivers/thermal/cpu_cooling.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/thermal/cpu_cooling.c +1 -1
@@ -477,7 +477,7 @@ __cpufreq_cooling_register(struct device_node *np, ret =get_idr (&cpufreq_idr, &cpufreq_dev->id);if (ret) {kfree (cpufreq_dev); -return ERR_PTR (-EINVAL ); +return ERR_PTR (cpufreq_dev->id); } snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
Signature · 1 line
2.0.3.693.g996b0fd
Re: [PATCH 11/26] cpu_cooling: propagate error returned by idr_alloc()
Quoted 12 lines · Viresh Kumar
We aren't supposed to return our own error type here. Return what we got.
Signed-off-by Viresh Kumar <[email protected]>--- drivers/thermal/cpu_cooling.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)drivers/thermal/cpu_cooling.c +0
-0
drivers/thermal/cpu_cooling.c __cpufreq_cooling_register(struct device_node *np, · line 480
Quoted 5 lines
drivers/thermal/cpu_cooling.c +1
-1@@ -477,7 +477,7 @@ __cpufreq_cooling_register(struct device_node *np, ret =get_idr (&cpufreq_idr, &cpufreq_dev->id);if (ret) {kfree (cpufreq_dev); -return ERR_PTR (-EINVAL ); +return ERR_PTR (cpufreq_dev->id);
The error is ret, not the id which is probably 0 if there was an error. So:
+ return ERR_PTR(ret);
Cheers,
Javi
Re: [PATCH 11/26] cpu_cooling: propagate error returned by idr_alloc()
Quoted 4 lines · Javi Merino
The error is ret, not the id which is probably 0 if there was an error. So:
+ return
ERR_PTR(ret);
Where should I hide my face, shameful mistake :(
Re: [PATCH 11/26] cpu_cooling: propagate error returned by idr_alloc()
In reply to Viresh KumarHello Viresh,
Quoted 2 lines · Viresh Kumar
We aren't supposed to return our own error type here. Return what we got.
OK..
Quoted 10 lines
Signed-off-by Viresh Kumar <[email protected]>--- drivers/thermal/cpu_cooling.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)drivers/thermal/cpu_cooling.c +0
-0
drivers/thermal/cpu_cooling.c __cpufreq_cooling_register(struct device_node *np, · line 480
Quoted 5 lines
drivers/thermal/cpu_cooling.c +1
-1@@ -477,7 +477,7 @@ __cpufreq_cooling_register(struct device_node *np, ret =get_idr (&cpufreq_idr, &cpufreq_dev->id);if (ret) {kfree (cpufreq_dev); -return ERR_PTR (-EINVAL ); +return ERR_PTR (cpufreq_dev->id);
cpufreq_dev is an invalid object here. Maybe you want to use ret in your patch?
Quoted 6 lines
drivers/thermal/cpu_cooling.c +0
-0} snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",Signature · 1 line
2.0.3.693.g996b0fd
PATCH 12/26 cpu_cooling: Don't match min/max frequencies for all CPUs on cooling register
In reply to Viresh KumarIn __cpufreq_cooling_register() we try to match min/max frequencies for all CPUs passed in 'clip_cpus' mask. This mask is the cpumask of cpus where the frequency constraints will be applied.
Same frequency constraint can be applied only to the CPUs belonging to the same cluster (i.e. CPUs sharing clock line). For all such CPUs we have a single 'struct cpufreq_policy' structure managing them and so getting policies for all CPUs wouldn't make any sense as they will all return the same pointer.
So, remove this useless check of checking min/max for all CPUs. Also update doc comment to make this more obvious that clip_cpus should be same as policy->related_cpus.
--- drivers/thermal/cpu_cooling.c | 19 ++----------------- 1 file changed, 2 insertions(+), 17 deletions(-)
drivers/thermal/cpu_cooling.c +2 -17
@@ -434,6 +434,7 @@ static struct notifier_block thermal_cpufreq_notifier_block = {* __cpufreq_cooling_register - helper function to create cpufreq cooling device * @np: a valid struct device_node to the cooling device device tree node * @clip_cpus: cpumask of cpus where the frequency constraints will happen. +* Normally this should be same as cpufreq policy->related_cpus. * * This interface function registers the cpufreq cooling device with the name * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
@@ -449,25 +450,9 @@ __cpufreq_cooling_register(struct device_node *np, {struct thermal_cooling_device *cool_dev;struct cpufreq_cooling_device *cpufreq_dev; -unsigned int min =0 , max =0 ;char dev_name[THERMAL_NAME_LENGTH ]; -int ret =0 , i; -struct cpufreq_policy policy; +int ret =0 ; -/* Verify that all the clip cpus have same freq_min, freq_max limit */ -for_each_cpu (i, clip_cpus) { -/* continue if cpufreq policy not found and not return error */ -if (!cpufreq_get_policy (&policy, i)) -continue ; -if (min ==0 && max ==0 ) { - min = policy.cpuinfo.min_freq; - max = policy.cpuinfo.max_freq; - }else { -if (min != policy.cpuinfo.min_freq || - max != policy.cpuinfo.max_freq) -return ERR_PTR (-EINVAL ); - } - } cpufreq_dev =kzalloc (sizeof (*cool_dev),GFP_KERNEL );if (!cpufreq_dev)return ERR_PTR (-ENOMEM );
Signature · 1 line
2.0.3.693.g996b0fd
PATCH 13/26 cpu_cooling: don't iterate over all allowed_cpus to update cpufreq policy
In reply to Viresh KumarAll CPUs present in 'allowed_cpus' share the same 'struct cpufreq_policy' structure and so calling cpufreq_update_policy() for each of them doesn't make sense.
--- drivers/thermal/cpu_cooling.c | 9 +++------ 1 file changed, 3 insertions(+), 6 deletions(-)
drivers/thermal/cpu_cooling.c +3 -6
@@ -286,11 +286,10 @@ static unsigned int get_cpu_frequency(unsigned int cpu, unsigned long level)static int cpufreq_apply_cooling (struct cpufreq_cooling_device *cpufreq_device,unsigned long cooling_state) { -unsigned int cpuid, clip_freq; +unsigned int clip_freq;struct cpumask *mask = &cpufreq_device->allowed_cpus;unsigned int cpu =cpumask_any (mask); -/* Check if the old cooling action is same as new cooling action */ if (cpufreq_device->cpufreq_state == cooling_state)return 0 ;
@@ -303,10 +302,8 @@ static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device, cpufreq_device->cpufreq_val = clip_freq; notify_device = cpufreq_device; -for_each_cpu (cpuid, mask) { -if (is_cpufreq_valid (cpuid)) -cpufreq_update_policy (cpuid); - } +if (is_cpufreq_valid (cpu)) +cpufreq_update_policy (cpu); notify_device =NOTIFY_INVALID ;
Signature · 1 line
2.0.3.693.g996b0fd
PATCH 14/26 cpu_cooling: Don't check is_cpufreq_valid()
In reply to Viresh KumarBecause get_cpu_frequency() has returned a valid frequency, it means that the cpufreq policy is surely valid and so no point checking that again with is_cpufreq_valid(). Get rid of the routine as well as there are no more users.
--- drivers/thermal/cpu_cooling.c | 20 +------------------- 1 file changed, 1 insertion(+), 19 deletions(-)
drivers/thermal/cpu_cooling.c +1 -19
@@ -111,23 +111,6 @@ static void release_idr(struct idr *idr, int id)/* Below code defines functions to be used for cpufreq as cooling device */ -/** -* is_cpufreq_valid - function to check frequency transitioning capability. -* @cpu: cpu for which check is needed. -* -* This function will check the current state of the system if -* it is capable of changing the frequency for a given @cpu. -* -* Return: 0 if the system is not currently capable of changing -* the frequency of given cpu. !0 in case the frequency is changeable. -*/ -static int is_cpufreq_valid (int cpu) -{ -struct cpufreq_policy policy; - -return !cpufreq_get_policy (&policy, cpu); -} -enum cpufreq_cooling_property {GET_LEVEL ,GET_FREQ ,
@@ -302,8 +285,7 @@ static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device, cpufreq_device->cpufreq_val = clip_freq; notify_device = cpufreq_device; -if (is_cpufreq_valid (cpu)) -cpufreq_update_policy (cpu); +cpufreq_update_policy (cpu); notify_device =NOTIFY_INVALID ;
Signature · 1 line
2.0.3.693.g996b0fd
PATCH 15/26 cpu_cooling: do error handling at the bottom in __cpufreq_cooling_register()
In reply to Viresh KumarThis makes life easy and bug free. And is scalable for future resource allocations.
--- drivers/thermal/cpu_cooling.c | 19 ++++++++++++------- 1 file changed, 12 insertions(+), 7 deletions(-)
drivers/thermal/cpu_cooling.c +12 -7
@@ -440,8 +440,8 @@ __cpufreq_cooling_register(struct device_node *np, ret =get_idr (&cpufreq_idr, &cpufreq_dev->id);if (ret) { -kfree (cpufreq_dev); -return ERR_PTR (cpufreq_dev->id); + cool_dev =ERR_PTR (cpufreq_dev->id); + goto free_cdev; } snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
@@ -449,11 +449,9 @@ __cpufreq_cooling_register(struct device_node *np, cool_dev =thermal_of_cooling_device_register (np, dev_name, cpufreq_dev, &cpufreq_cooling_ops); -if (IS_ERR (cool_dev)) { -release_idr (&cpufreq_idr, cpufreq_dev->id); -kfree (cpufreq_dev); -return cool_dev; - } +if (IS_ERR (cool_dev)) + goto remove_idr; + cpufreq_dev->cool_dev = cool_dev;mutex_lock (&cooling_cpufreq_lock);
@@ -467,6 +465,13 @@ __cpufreq_cooling_register(struct device_node *np,mutex_unlock (&cooling_cpufreq_lock);return cool_dev; + +remove_idr: +release_idr (&cpufreq_idr, cpufreq_dev->id); +free_cdev: +kfree (cpufreq_dev); + +return cool_dev; }/**
Signature · 1 line
2.0.3.693.g996b0fd
Re: [PATCH 15/26] cpu_cooling: do error handling at the bottom in __cpufreq_cooling_register()
Quoted 4 lines · Viresh Kumar
This makes life easy and bug free. And is scalable for future resource allocations.
Signed-off-by Viresh Kumar <[email protected]>
Yay! We have a similar fix as part of our patches for the power allocator governor (the only difference is that the instead of calling the label "remove_idr", we call it "release_idr"). So quite happy to see this going in. FWIW,
PATCH 16/26 cpu_cooling: Drop useless locking around idr_alloc/idr_remove
In reply to Viresh KumarLocking around idr_alloc/idr_remove looks rather pointless as there is no race it is trying to fix. Remove it.
get_idr() and release_idr() aren't much useful now, so get rid of them as well.
---
@Eduardo: Same is true for thermal-core as well ?
--- drivers/thermal/cpu_cooling.c | 45 ++++--------------------------------------- 1 file changed, 4 insertions(+), 41 deletions(-)
drivers/thermal/cpu_cooling.c +4 -41
@@ -73,42 +73,6 @@ static unsigned int cpufreq_dev_count;#define NOTIFY_INVALID NULLstatic struct cpufreq_cooling_device *notify_device; -/** -* get_idr - function to get a unique id. -* @idr: struct idr * handle used to create a id. -* @id: int * value generated by this function. -* -* This function will populate @id with an unique -* id, using the idr API. -* -* Return: 0 on success, an error code on failure. -*/ -static int get_idr (struct idr *idr,int *id) -{ -int ret; - -mutex_lock (&cooling_cpufreq_lock); - ret =idr_alloc (idr,NULL ,0 ,0 ,GFP_KERNEL ); -mutex_unlock (&cooling_cpufreq_lock); -if (unlikely (ret <0 )) -return ret; - *id = ret; - -return 0 ; -} - -/** -* release_idr - function to free the unique id. -* @idr: struct idr * handle used for creating the id. -* @id: int value representing the unique id. -*/ -static void release_idr (struct idr *idr,int id) -{ -mutex_lock (&cooling_cpufreq_lock); -idr_remove (idr, id); -mutex_unlock (&cooling_cpufreq_lock); -} -/* Below code defines functions to be used for cpufreq as cooling device */ enum cpufreq_cooling_property {
@@ -430,7 +394,6 @@ __cpufreq_cooling_register(struct device_node *np,struct thermal_cooling_device *cool_dev;struct cpufreq_cooling_device *cpufreq_dev;char dev_name[THERMAL_NAME_LENGTH ]; -int ret =0 ; cpufreq_dev =kzalloc (sizeof (*cool_dev),GFP_KERNEL );if (!cpufreq_dev)
@@ -438,8 +401,8 @@ __cpufreq_cooling_register(struct device_node *np,cpumask_copy (&cpufreq_dev->allowed_cpus, clip_cpus); - ret =get_idr (&cpufreq_idr, &cpufreq_dev->id); -if (ret) { + cpufreq_dev->id =idr_alloc (&cpufreq_idr,NULL ,0 ,0 ,GFP_KERNEL ); +if (unlikely (cpufreq_dev->id <0 )) { cool_dev =ERR_PTR (cpufreq_dev->id); goto free_cdev; }
@@ -467,7 +430,7 @@ __cpufreq_cooling_register(struct device_node *np,return cool_dev; remove_idr: -release_idr (&cpufreq_idr, cpufreq_dev->id); +idr_remove (&cpufreq_idr, cpufreq_dev->id); free_cdev:kfree (cpufreq_dev);
@@ -540,7 +503,7 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)mutex_unlock (&cooling_cpufreq_lock);thermal_cooling_device_unregister (cpufreq_dev->cool_dev); -release_idr (&cpufreq_idr, cpufreq_dev->id); +idr_remove (&cpufreq_idr, cpufreq_dev->id);kfree (cpufreq_dev); }EXPORT_SYMBOL_GPL (cpufreq_cooling_unregister);
Signature · 1 line
2.0.3.693.g996b0fd
Re: [PATCH 16/26] cpu_cooling: Drop useless locking around idr_alloc/idr_remove
Hi Viresh,
Quoted 2 lines · Viresh Kumar
Locking around idr_alloc/idr_remove looks rather pointless as there is no race it is trying to fix. Remove it.
You are assuming that all cpufreq cooling devices are registered sequentially, one after the other. That doesn't need be the case. I don't think the performance that you get from this patch justifies the possible races that could be introduced by not having the locking. Why should we remove this?
Quoted 5 lines
get_idr()andrelease_idr()aren't much useful now, so get rid of them as well.Signed-off-by Viresh Kumar <[email protected]>---
@Eduardo: Same is true for thermal-core as well ?
I think that my previous concern applies to thermal_core as well, thermal zones may not be initialised sequentially.
Cheers,
Javi
Re: [PATCH 16/26] cpu_cooling: Drop useless locking around idr_alloc/idr_remove
In reply to Viresh KumarQuoted 3 lines · Viresh Kumar
Locking around idr_alloc/idr_remove looks rather pointless as there is no race it is trying to fix. Remove it.
Can you please elaborate on how the idr's are going to be serialize without the lock?
Quoted 5 lines
get_idr()andrelease_idr()aren't much useful now, so get rid of them as well.Signed-off-by Viresh Kumar <[email protected]>---
@Eduardo: Same is true for thermal-core as well ?
Probably not ?
Quoted 91 lines
--- drivers/thermal/cpu_cooling.c | 45 ++++--------------------------------------- 1 file changed, 4 insertions(+), 41 deletions(-)drivers/thermal/cpu_cooling.c +4
-41@@ -73,42 +73,6 @@ static unsigned int cpufreq_dev_count;#define NOTIFY_INVALID NULLstatic struct cpufreq_cooling_device *notify_device; -/** -* get_idr - function to get a unique id. -* @idr: struct idr * handle used to create a id. -* @id: int * value generated by this function. -* -* This function will populate @id with an unique -* id, using the idr API. -* -* Return: 0 on success, an error code on failure. -*/ -static int get_idr (struct idr *idr,int *id) -{ -int ret; - -mutex_lock (&cooling_cpufreq_lock); - ret =idr_alloc (idr,NULL ,0 ,0 ,GFP_KERNEL ); -mutex_unlock (&cooling_cpufreq_lock); -if (unlikely (ret <0 )) -return ret; - *id = ret; - -return 0 ; -} - -/** -* release_idr - function to free the unique id. -* @idr: struct idr * handle used for creating the id. -* @id: int value representing the unique id. -*/ -static void release_idr (struct idr *idr,int id) -{ -mutex_lock (&cooling_cpufreq_lock); -idr_remove (idr, id); -mutex_unlock (&cooling_cpufreq_lock); -} -/* Below code defines functions to be used for cpufreq as cooling device */ enum cpufreq_cooling_property {@@ -430,7 +394,6 @@ __cpufreq_cooling_register(struct device_node *np,struct thermal_cooling_device *cool_dev;struct cpufreq_cooling_device *cpufreq_dev;char dev_name[THERMAL_NAME_LENGTH ]; -int ret =0 ; cpufreq_dev =kzalloc (sizeof (*cool_dev),GFP_KERNEL );if (!cpufreq_dev)@@ -438,8 +401,8 @@ __cpufreq_cooling_register(struct device_node *np,cpumask_copy (&cpufreq_dev->allowed_cpus, clip_cpus); - ret =get_idr (&cpufreq_idr, &cpufreq_dev->id); -if (ret) { + cpufreq_dev->id =idr_alloc (&cpufreq_idr,NULL ,0 ,0 ,GFP_KERNEL ); +if (unlikely (cpufreq_dev->id <0 )) { cool_dev =ERR_PTR (cpufreq_dev->id); goto free_cdev; }@@ -467,7 +430,7 @@ __cpufreq_cooling_register(struct device_node *np,return cool_dev; remove_idr: -release_idr (&cpufreq_idr, cpufreq_dev->id); +idr_remove (&cpufreq_idr, cpufreq_dev->id); free_cdev:kfree (cpufreq_dev);@@ -540,7 +503,7 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)mutex_unlock (&cooling_cpufreq_lock);thermal_cooling_device_unregister (cpufreq_dev->cool_dev); -release_idr (&cpufreq_idr, cpufreq_dev->id); +idr_remove (&cpufreq_idr, cpufreq_dev->id);kfree (cpufreq_dev); }EXPORT_SYMBOL_GPL (cpufreq_cooling_unregister);Signature · 1 line
2.0.3.693.g996b0fd
Re: [PATCH 16/26] cpu_cooling: Drop useless locking around idr_alloc/idr_remove
Quoted 7 lines · Eduardo Valentin
Quoted 3 lines · Viresh Kumar
Locking around idr_alloc/idr_remove looks rather pointless as there is no race it is trying to fix. Remove it.
Can you please elaborate on how the idr's are going to be serialize without the lock?
Dropped this patch, I was wrong ..
PATCH 17/26 cpu_cooling: Merge cpufreq_apply_cooling() into cpufreq_set_cur_state()
In reply to Viresh Kumarcpufreq_apply_cooling() has a single caller, cpufreq_set_cur_state() and cpufreq_set_cur_state() is an unnecessary wrapper over cpufreq_apply_cooling().
Get rid of it by merging both routines.
--- drivers/thermal/cpu_cooling.c | 58 ++++++++++++++----------------------------- 1 file changed, 19 insertions(+), 39 deletions(-)
drivers/thermal/cpu_cooling.c +19 -39
@@ -219,44 +219,6 @@ static unsigned int get_cpu_frequency(unsigned int cpu, unsigned long level) }/** -* cpufreq_apply_cooling - function to apply frequency clipping. -* @cpufreq_device: cpufreq_cooling_device pointer containing frequency -* clipping data. -* @cooling_state: value of the cooling state. -* -* Function used to make sure the cpufreq layer is aware of current thermal -* limits. The limits are applied by updating the cpufreq policy. -* -* Return: 0 on success, an error code otherwise (-EINVAL in case wrong -* cooling state). -*/ -static int cpufreq_apply_cooling (struct cpufreq_cooling_device *cpufreq_device, -unsigned long cooling_state) -{ -unsigned int clip_freq; -struct cpumask *mask = &cpufreq_device->allowed_cpus; -unsigned int cpu =cpumask_any (mask); - -/* Check if the old cooling action is same as new cooling action */ -if (cpufreq_device->cpufreq_state == cooling_state) -return 0 ; - - clip_freq =get_cpu_frequency (cpu, cooling_state); -if (!clip_freq) -return -EINVAL ; - - cpufreq_device->cpufreq_state = cooling_state; - cpufreq_device->cpufreq_val = clip_freq; - notify_device = cpufreq_device; - -cpufreq_update_policy (cpu); - - notify_device =NOTIFY_INVALID ; - -return 0 ; -} - -/** * cpufreq_thermal_notifier - notifier callback for cpufreq policy change. * @nb: struct notifier_block * with callback info. * @event: value showing cpufreq event for which this function invoked.
@@ -357,8 +319,26 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, unsigned long state) {struct cpufreq_cooling_device *cpufreq_device = cdev->devdata; +unsigned int cpu =cpumask_any (&cpufreq_device->allowed_cpus); +unsigned int clip_freq; -return cpufreq_apply_cooling (cpufreq_device, state); +/* Check if the old cooling action is same as new cooling action */ +if (cpufreq_device->cpufreq_state == state) +return 0 ; + + clip_freq =get_cpu_frequency (cpu, state); +if (!clip_freq) +return -EINVAL ; + + cpufreq_device->cpufreq_state = state; + cpufreq_device->cpufreq_val = clip_freq; + notify_device = cpufreq_device; + +cpufreq_update_policy (cpu); + + notify_device =NOTIFY_INVALID ; + +return 0 ; }/* Bind cpufreq callbacks to thermal cooling device ops */
Signature · 1 line
2.0.3.693.g996b0fd
PATCH 18/26 cpu_cooling: Merge get_cpu_frequency() into cpufreq_set_cur_state()
In reply to Viresh Kumarget_cpu_frequency() is used from only one place, i.e. cpufreq_set_cur_state(). And there is no need to have this extra level of function calls. Merge them.
--- drivers/thermal/cpu_cooling.c | 31 ++++--------------------------- 1 file changed, 4 insertions(+), 27 deletions(-)
drivers/thermal/cpu_cooling.c +4 -27
@@ -195,30 +195,6 @@ unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq)EXPORT_SYMBOL_GPL (cpufreq_cooling_get_level);/** -* get_cpu_frequency - get the absolute value of frequency from level. -* @cpu: cpu for which frequency is fetched. -* @level: cooling level -* -* This function matches cooling level with frequency. Based on a cooling level -* of frequency, equals cooling state of cpu cooling device, it will return -* the corresponding frequency. -* e.g level=0 --> 1st MAX FREQ, level=1 ---> 2nd MAX FREQ, .... etc -* -* Return: 0 on error, the corresponding frequency otherwise. -*/ -static unsigned int get_cpu_frequency (unsigned int cpu,unsigned long level) -{ -int ret =0 ; -unsigned int freq; - - ret =get_property (cpu, level, &freq,GET_FREQ ); -if (ret) -return 0 ; - -return freq; -} - -/** * cpufreq_thermal_notifier - notifier callback for cpufreq policy change. * @nb: struct notifier_block * with callback info. * @event: value showing cpufreq event for which this function invoked.
@@ -321,14 +297,15 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;unsigned int cpu =cpumask_any (&cpufreq_device->allowed_cpus);unsigned int clip_freq; +int ret =0 ;/* Check if the old cooling action is same as new cooling action */ if (cpufreq_device->cpufreq_state == state)return 0 ; - clip_freq =get_cpu_frequency (cpu, state); -if (!clip_freq) -return -EINVAL ; + ret =get_property (cpu, state, &clip_freq,GET_FREQ ); +if (ret) +return ret; cpufreq_device->cpufreq_state = state; cpufreq_device->cpufreq_val = clip_freq;
Signature · 1 line
2.0.3.693.g996b0fd
PATCH 19/26 cpu_cooling: find max level during device registration
In reply to Viresh KumarCPU frequency tables don't update after the driver is registered and so we don't need to iterate over them to find total number of states every time cpufreq_get_max_state() is called. Do it once at boot time.
--- drivers/thermal/cpu_cooling.c | 31 +++++++++++++++++++------------ 1 file changed, 19 insertions(+), 12 deletions(-)
drivers/thermal/cpu_cooling.c +19 -12
@@ -52,6 +52,8 @@* cooling devices. * @cpufreq_val: integer value representing the absolute value of the clipped * frequency. +* @max_level: maximum cooling level. One less than total number of valid +* cpufreq frequencies. * @allowed_cpus: all the cpus involved for this cpufreq_cooling_device. * * This structure is required for keeping information of each registered
@@ -62,6 +64,7 @@ struct cpufreq_cooling_device {struct thermal_cooling_device *cool_dev;unsigned int cpufreq_state;unsigned int cpufreq_val; +unsigned int max_level;struct cpumask allowed_cpus; };static DEFINE_IDR (cpufreq_idr);
@@ -246,19 +249,9 @@ static int cpufreq_get_max_state(struct thermal_cooling_device *cdev, unsigned long *state) {struct cpufreq_cooling_device *cpufreq_device = cdev->devdata; -struct cpumask *mask = &cpufreq_device->allowed_cpus; -unsigned int cpu; -unsigned int count =0 ; -int ret; - cpu =cpumask_any (mask); - - ret =get_property (cpu,0 , &count,GET_MAXL ); - -if (count >0 ) - *state = count; - -return ret; + *state = cpufreq_device->max_level; +return 0 ; }/**
@@ -351,11 +344,25 @@ __cpufreq_cooling_register(struct device_node *np,struct thermal_cooling_device *cool_dev;struct cpufreq_cooling_device *cpufreq_dev;char dev_name[THERMAL_NAME_LENGTH ]; +struct cpufreq_frequency_table *pos, *table; + + table =cpufreq_frequency_get_table (cpumask_first (clip_cpus)); +if (!table) { +pr_debug ("%s: CPUFreq table not found\n" , __func__); +return ERR_PTR (-EPROBE_DEFER ); + } cpufreq_dev =kzalloc (sizeof (*cool_dev),GFP_KERNEL );if (!cpufreq_dev)return ERR_PTR (-ENOMEM ); +/* Find max levels */ +cpufreq_for_each_valid_entry (pos, table) + cpufreq_dev->max_level++; + +/* max_level is an index, not a counter */ + cpufreq_dev->max_level--; +cpumask_copy (&cpufreq_dev->allowed_cpus, clip_cpus); cpufreq_dev->id =idr_alloc (&cpufreq_idr,NULL ,0 ,0 ,GFP_KERNEL );
Signature · 1 line
2.0.3.693.g996b0fd
Re: [PATCH 19/26] cpu_cooling: find max level during device registration
Viresh
Quoted 3 lines · Viresh Kumar
CPU frequency tables don't update after the driver is registered and so we don't need to iterate over them to find total number of states every time
cpufreq_get_max_state()is called. Do it once at boot time.
Could you please update me regarding the story behind the opp del patch set?
http://permalink.gmane.org/gmane.linux.power-management.general/53348
Quoted 78 lines
Signed-off-by Viresh Kumar <[email protected]>--- drivers/thermal/cpu_cooling.c | 31 +++++++++++++++++++------------ 1 file changed, 19 insertions(+), 12 deletions(-)drivers/thermal/cpu_cooling.c +19
-12@@ -52,6 +52,8 @@* cooling devices. * @cpufreq_val: integer value representing the absolute value of the clipped * frequency. +* @max_level: maximum cooling level. One less than total number of valid +* cpufreq frequencies. * @allowed_cpus: all the cpus involved for this cpufreq_cooling_device. * * This structure is required for keeping information of each registered @@ -62,6 +64,7 @@ struct cpufreq_cooling_device {struct thermal_cooling_device *cool_dev;unsigned int cpufreq_state;unsigned int cpufreq_val; +unsigned int max_level;struct cpumask allowed_cpus; };static DEFINE_IDR (cpufreq_idr);@@ -246,19 +249,9 @@ static int cpufreq_get_max_state(struct thermal_cooling_device *cdev, unsigned long *state) {struct cpufreq_cooling_device *cpufreq_device = cdev->devdata; -struct cpumask *mask = &cpufreq_device->allowed_cpus; -unsigned int cpu; -unsigned int count =0 ; -int ret; - cpu =cpumask_any (mask); - - ret =get_property (cpu,0 , &count,GET_MAXL ); - -if (count >0 ) - *state = count; - -return ret; + *state = cpufreq_device->max_level; +return 0 ; }/** @@ -351,11 +344,25 @@ __cpufreq_cooling_register(struct device_node *np,struct thermal_cooling_device *cool_dev;struct cpufreq_cooling_device *cpufreq_dev;char dev_name[THERMAL_NAME_LENGTH ]; +struct cpufreq_frequency_table *pos, *table; + + table =cpufreq_frequency_get_table (cpumask_first (clip_cpus)); +if (!table) { +pr_debug ("%s: CPUFreq table not found\n" , __func__); +return ERR_PTR (-EPROBE_DEFER ); + } cpufreq_dev =kzalloc (sizeof (*cool_dev),GFP_KERNEL );if (!cpufreq_dev)return ERR_PTR (-ENOMEM ); +/* Find max levels */ +cpufreq_for_each_valid_entry (pos, table) + cpufreq_dev->max_level++; + +/* max_level is an index, not a counter */ + cpufreq_dev->max_level--; +cpumask_copy (&cpufreq_dev->allowed_cpus, clip_cpus); cpufreq_dev->id =idr_alloc (&cpufreq_idr,NULL ,0 ,0 ,GFP_KERNEL );Signature · 1 line
2.0.3.693.g996b0fd
Re: [PATCH 19/26] cpu_cooling: find max level during device registration
Quoted 4 lines · Eduardo Valentin
Could you please update me regarding the story behind the opp del patch set?
http://permalink.gmane.org/gmane.linux.power-management.general/53348
Its merged by Rafael, should be in next now.
Re: [PATCH 19/26] cpu_cooling: find max level during device registration
Quoted 7 lines · Viresh Kumar
Quoted 4 lines · Eduardo Valentin
Could you please update me regarding the story behind the opp del patch set?
http://permalink.gmane.org/gmane.linux.power-management.general/53348
Its merged by Rafael, should be in next now.
OK. Good. But does it mean we can remove OPPs after cpufreq registration? Meaning, is the cpufreq table changing over time?
BR,
Eduardo Valentin
PATCH 20/26 cpu_cooling: get_property() doesn't need to support GET_MAXL anymore
In reply to Viresh KumarWe don't use get_property() to find max levels anymore as it is done at boot now. So, don't support GET_MAXL in get_property().
--- drivers/thermal/cpu_cooling.c | 14 +++----------- 1 file changed, 3 insertions(+), 11 deletions(-)
drivers/thermal/cpu_cooling.c +3 -11
@@ -81,7 +81,6 @@ static struct cpufreq_cooling_device *notify_device;enum cpufreq_cooling_property {GET_LEVEL ,GET_FREQ , -GET_MAXL , };/**
@@ -89,12 +88,11 @@ enum cpufreq_cooling_property {* @cpu: cpu for which the property is required * @input: query parameter * @output: query return -* @property: type of query (frequency, level, max level) +* @property: type of query (frequency, level) * * This is the common function to -* 1. get maximum cpu cooling states -* 2. translate frequency to cooling state -* 3. translate cooling state to frequency +* 1. translate frequency to cooling state +* 2. translate cooling state to frequency * * Note that the code may be not in good shape * but it is written in this way in order to:
@@ -141,12 +139,6 @@ static int get_property(unsigned int cpu, unsigned long input,/* max_level is an index, not a counter */ max_level--; -/* get max level */ -if (property ==GET_MAXL ) { - *output = (unsigned int )max_level; -return 0 ; - } -if (property ==GET_FREQ ) level = descend ? input : (max_level - input);
Signature · 1 line
2.0.3.693.g996b0fd
PATCH 21/26 cpu_cooling: create list of cpufreq_cooling_devices
In reply to Viresh KumarThat will be used by later patches to iterate over all cpufreq cooling devices.
--- drivers/thermal/cpu_cooling.c | 6 ++++++ 1 file changed, 6 insertions(+)
drivers/thermal/cpu_cooling.c +6 -0
@@ -66,8 +66,11 @@ struct cpufreq_cooling_device {unsigned int cpufreq_val;unsigned int max_level;struct cpumask allowed_cpus; +struct list_head head; }; +static DEFINE_IDR (cpufreq_idr); +static LIST_HEAD (cpufreq_dev_list);static DEFINE_MUTEX (cooling_cpufreq_lock);static unsigned int cpufreq_dev_count;
@@ -372,6 +375,7 @@ __cpufreq_cooling_register(struct device_node *np, goto remove_idr; cpufreq_dev->cool_dev = cool_dev; +INIT_LIST_HEAD (&cpufreq_dev->head);mutex_lock (&cooling_cpufreq_lock);
@@ -381,6 +385,7 @@ __cpufreq_cooling_register(struct device_node *np, CPUFREQ_POLICY_NOTIFIER); cpufreq_dev_count++; +list_add (&cpufreq_dev->head, &cpufreq_dev_list);mutex_unlock (&cooling_cpufreq_lock);return cool_dev;
@@ -451,6 +456,7 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) cpufreq_dev = cdev->devdata;mutex_lock (&cooling_cpufreq_lock); cpufreq_dev_count--; +list_del (&cpufreq_dev->head);/* Unregister the notifier for the last cpufreq cooling device */ if (cpufreq_dev_count ==0 )
Signature · 1 line
2.0.3.693.g996b0fd
Re: [PATCH 21/26] cpu_cooling: create list of cpufreq_cooling_devices
Viresh,
Quoted 2 lines · Viresh Kumar
That will be used by later patches to iterate over all cpufreq cooling devices.
Can you please refresh the series on top of latest Linus tree (material for 3.18-rc7) ?
Quoted 10 lines
Signed-off-by Viresh Kumar <[email protected]>--- drivers/thermal/cpu_cooling.c | 6 ++++++ 1 file changed, 6 insertions(+)drivers/thermal/cpu_cooling.c +0
-0
drivers/thermal/cpu_cooling.c struct cpufreq_cooling_device { · line 69
Quoted 4 lines
drivers/thermal/cpu_cooling.c +1
-0@@ -66,8 +66,11 @@ struct cpufreq_cooling_device {unsigned int cpufreq_val;unsigned int max_level;struct cpumask allowed_cpus; +struct list_head head;
Yadwinder has already introduced a list of cpu cooling devs:
commit 2dcd851fe4b4fe60c2f8520bf7668d7e9b2dd76b
Author: Yadwinder Singh Brar <[email protected]> Date: Fri Nov 7 19:12:29 2014 +0530
thermal: cpu_cooling: Update always cpufreq policy with thermal constraints
Quoted 34 lines
drivers/thermal/cpu_cooling.c +5
-0}; +static DEFINE_IDR (cpufreq_idr); +static LIST_HEAD (cpufreq_dev_list);static DEFINE_MUTEX (cooling_cpufreq_lock);static unsigned int cpufreq_dev_count;@@ -372,6 +375,7 @@ __cpufreq_cooling_register(struct device_node *np, goto remove_idr; cpufreq_dev->cool_dev = cool_dev; +INIT_LIST_HEAD (&cpufreq_dev->head);mutex_lock (&cooling_cpufreq_lock);@@ -381,6 +385,7 @@ __cpufreq_cooling_register(struct device_node *np, CPUFREQ_POLICY_NOTIFIER); cpufreq_dev_count++; +list_add (&cpufreq_dev->head, &cpufreq_dev_list);mutex_unlock (&cooling_cpufreq_lock);return cool_dev;@@ -451,6 +456,7 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) cpufreq_dev = cdev->devdata;mutex_lock (&cooling_cpufreq_lock); cpufreq_dev_count--; +list_del (&cpufreq_dev->head);/* Unregister the notifier for the last cpufreq cooling device */ if (cpufreq_dev_count ==0 )Signature · 1 line
2.0.3.693.g996b0fd
PATCH 22/26 cpu_cooling: use cpufreq_dev_list instead of cpufreq_dev_count
In reply to Viresh KumarAs we already have a list of cpufreq_cooling_devices now, lets use it instead of a local counter.
--- drivers/thermal/cpu_cooling.c | 8 ++------ 1 file changed, 2 insertions(+), 6 deletions(-)
drivers/thermal/cpu_cooling.c +2 -6
@@ -73,8 +73,6 @@ static DEFINE_IDR(cpufreq_idr);static LIST_HEAD (cpufreq_dev_list);static DEFINE_MUTEX (cooling_cpufreq_lock); -static unsigned int cpufreq_dev_count; -/* notify_table passes value to the CPUFREQ_ADJUST callback function. */ #define NOTIFY_INVALID NULLstatic struct cpufreq_cooling_device *notify_device;
@@ -380,10 +378,9 @@ __cpufreq_cooling_register(struct device_node *np,mutex_lock (&cooling_cpufreq_lock);/* Register the notifier for first cpufreq cooling device */ -if (cpufreq_dev_count ==0 ) +if (list_empty (&cpufreq_dev_list))cpufreq_register_notifier (&thermal_cpufreq_notifier_block,CPUFREQ_POLICY_NOTIFIER ); - cpufreq_dev_count++;list_add (&cpufreq_dev->head, &cpufreq_dev_list);mutex_unlock (&cooling_cpufreq_lock);
@@ -455,11 +452,10 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) cpufreq_dev = cdev->devdata;mutex_lock (&cooling_cpufreq_lock); - cpufreq_dev_count--;list_del (&cpufreq_dev->head);/* Unregister the notifier for the last cpufreq cooling device */ -if (cpufreq_dev_count ==0 ) +if (list_empty (&cpufreq_dev_list))cpufreq_unregister_notifier (&thermal_cpufreq_notifier_block,CPUFREQ_POLICY_NOTIFIER );mutex_unlock (&cooling_cpufreq_lock);
Signature · 1 line
2.0.3.693.g996b0fd
PATCH 23/26 cpu_cooling: Pass 'cpufreq_dev' to get_property()
In reply to Viresh KumarWe already know the value of 'cpufreq_dev->max_level' and so there is no need calculating that once again. For this, we need to send 'cpufreq_dev' to get_property().
Make all necessary changes for this change. Because cpufreq_cooling_get_level() doesn't have access to 'cpufreq_dev', it is updated to iterate over the list of cpufreq_cooling_devices to get cooling device for the cpu number passed to it. This also makes it robust to return levels only for the CPU registered via a cooling device. We don't have to support anything that isn't registered yet.
--- drivers/thermal/cpu_cooling.c | 47 ++++++++++++++++++++++++------------------- 1 file changed, 26 insertions(+), 21 deletions(-)
drivers/thermal/cpu_cooling.c +26 -21
@@ -86,7 +86,7 @@ enum cpufreq_cooling_property {/** * get_property - fetch a property of interest for a given cpu. -* @cpu: cpu for which the property is required +* @cpufreq_dev: cpufreq_dev for which the property is required * @input: query parameter * @output: query return * @property: type of query (frequency, level)
@@ -103,20 +103,20 @@ enum cpufreq_cooling_property {* * Return: 0 on success, -EINVAL when invalid parameters are passed. */ -static int get_property (unsigned int cpu,unsigned long input, -unsigned int *output, +static int get_property (struct cpufreq_cooling_device *cpufreq_dev, +unsigned long input,unsigned int *output,enum cpufreq_cooling_property property) {int i; -unsigned long max_level =0 , level =0 ; +unsigned long level =0 ;unsigned int freq =CPUFREQ_ENTRY_INVALID ;int descend =-1 ; -struct cpufreq_frequency_table *pos, *table = -cpufreq_frequency_get_table (cpu); +struct cpufreq_frequency_table *pos, *table;if (!output)return -EINVAL ; + table =cpufreq_frequency_get_table (cpumask_first (&cpufreq_dev->allowed_cpus));if (!table)return -EINVAL ;
@@ -130,18 +130,10 @@ static int get_property(unsigned int cpu, unsigned long input, descend = freq > pos->frequency; freq = pos->frequency; - max_level++; } -/* No valid cpu frequency entry */ -if (max_level ==0 ) -return -EINVAL ; - -/* max_level is an index, not a counter */ - max_level--; -if (property ==GET_FREQ ) - level = descend ? input : (max_level - input); + level = descend ? input : (cpufreq_dev->max_level - input); i =0 ;cpufreq_for_each_valid_entry (pos, table) {
@@ -154,7 +146,7 @@ static int get_property(unsigned int cpu, unsigned long input,if (property ==GET_LEVEL && (unsigned int )input == freq) {/* get level by frequency */ - *output = descend ? i : (max_level - i); + *output = descend ? i : (cpufreq_dev->max_level - i);return 0 ; }if (property ==GET_FREQ && level == i) {
@@ -181,12 +173,25 @@ static int get_property(unsigned int cpu, unsigned long input,*/ unsigned long cpufreq_cooling_get_level (unsigned int cpu,unsigned int freq) { -unsigned int val; +struct cpufreq_cooling_device *cpufreq_dev; -if (get_property (cpu, (unsigned long )freq, &val,GET_LEVEL )) -return THERMAL_CSTATE_INVALID ; +mutex_lock (&cooling_cpufreq_lock); +list_for_each_entry (cpufreq_dev, &cpufreq_dev_list, head) { +if (cpumask_test_cpu (cpu, &cpufreq_dev->allowed_cpus)) { +unsigned int val; + +mutex_unlock (&cooling_cpufreq_lock); +if (get_property (cpufreq_dev, (unsigned long )freq, &val, +GET_LEVEL )) +return THERMAL_CSTATE_INVALID ; + +return (unsigned long )val; + } + } +mutex_unlock (&cooling_cpufreq_lock); -return (unsigned long )val; +pr_err ("%s: cpu:%d not part of any cooling device\n" , __func__, cpu); +return THERMAL_CSTATE_INVALID ; }EXPORT_SYMBOL_GPL (cpufreq_cooling_get_level);
@@ -289,7 +294,7 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,if (cpufreq_device->cpufreq_state == state)return 0 ; - ret =get_property (cpu, state, &clip_freq,GET_FREQ ); + ret =get_property (cpufreq_device, state, &clip_freq,GET_FREQ );if (ret)return ret;
Signature · 1 line
2.0.3.693.g996b0fd
PATCH 24/26 cpu_cooling: Store frequencies in descending order
In reply to Viresh KumarCPUFreq framework *doesn't* guarantee that frequencies present in cpufreq table will be in ascending or descending order. But cpu_cooling somehow assumes that.
Probably because most of current users are creating this list from DT, which is done with the help of OPP layer. And OPP layer creates the list in ascending order of frequencies.
But cpu_cooling can be used for other platforms too, which don't have frequencies arranged in any order.
This patch tries to fix this issue by creating another list of valid frequencies in descending order. Care is also taken to throw warnings for duplicate entries.
Later patches would use it to simplify code.
--- drivers/thermal/cpu_cooling.c | 41 ++++++++++++++++++++++++++++++++++++++++- 1 file changed, 40 insertions(+), 1 deletion(-)
drivers/thermal/cpu_cooling.c +40 -1
@@ -65,6 +65,7 @@ struct cpufreq_cooling_device {unsigned int cpufreq_state;unsigned int cpufreq_val;unsigned int max_level; +unsigned int *freq_table;/* In descending order */ struct cpumask allowed_cpus;struct list_head head; };
@@ -321,6 +322,20 @@ static struct notifier_block thermal_cpufreq_notifier_block = { .notifier_call = cpufreq_thermal_notifier, }; +static unsigned int find_next_max (struct cpufreq_frequency_table *table, +unsigned int prev_max) +{ +struct cpufreq_frequency_table *pos; +unsigned int max =0 ; + +cpufreq_for_each_valid_entry (pos, table) { +if (pos->frequency > max && pos->frequency < prev_max) + max = pos->frequency; + } + +return max; +} +/** * __cpufreq_cooling_register - helper function to create cpufreq cooling device * @np: a valid struct device_node to the cooling device device tree node
@@ -343,6 +358,7 @@ __cpufreq_cooling_register(struct device_node *np,struct cpufreq_cooling_device *cpufreq_dev;char dev_name[THERMAL_NAME_LENGTH ];struct cpufreq_frequency_table *pos, *table; +unsigned int freq, i; table =cpufreq_frequency_get_table (cpumask_first (clip_cpus));if (!table) {
@@ -358,6 +374,14 @@ __cpufreq_cooling_register(struct device_node *np,cpufreq_for_each_valid_entry (pos, table) cpufreq_dev->max_level++; + cpufreq_dev->freq_table =kmalloc (sizeof (*cpufreq_dev->freq_table) * + cpufreq_dev->max_level,GFP_KERNEL ); +if (!cpufreq_dev->freq_table) { +return ERR_PTR (-ENOMEM ); + cool_dev =ERR_PTR (-ENOMEM ); + goto free_cdev; + } +/* max_level is an index, not a counter */ cpufreq_dev->max_level--;
@@ -366,7 +390,7 @@ __cpufreq_cooling_register(struct device_node *np, cpufreq_dev->id =idr_alloc (&cpufreq_idr,NULL ,0 ,0 ,GFP_KERNEL );if (unlikely (cpufreq_dev->id <0 )) { cool_dev =ERR_PTR (cpufreq_dev->id); - goto free_cdev; + goto free_table; } snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
@@ -377,6 +401,18 @@ __cpufreq_cooling_register(struct device_node *np,if (IS_ERR (cool_dev)) goto remove_idr; +/* Fill freq-table in descending order of frequencies */ +for (i =0 , freq =-1 ; i <= cpufreq_dev->max_level; i++) { + freq =find_next_max (table, freq); + cpufreq_dev->freq_table[i] = freq; + +/* Warn for duplicate entries */ +if (!freq) +pr_warn ("%s: table has duplicate entries\n" , __func__); +else +pr_debug ("%s: freq:%u KHz\n" , __func__, freq); + } + cpufreq_dev->cool_dev = cool_dev;INIT_LIST_HEAD (&cpufreq_dev->head);
@@ -394,6 +430,8 @@ __cpufreq_cooling_register(struct device_node *np, remove_idr:idr_remove (&cpufreq_idr, cpufreq_dev->id); +free_table: +kfree (cpufreq_dev->freq_table); free_cdev:kfree (cpufreq_dev);
@@ -467,6 +505,7 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)thermal_cooling_device_unregister (cpufreq_dev->cool_dev);idr_remove (&cpufreq_idr, cpufreq_dev->id); +kfree (cpufreq_dev->freq_table);kfree (cpufreq_dev); }EXPORT_SYMBOL_GPL (cpufreq_cooling_unregister);
Signature · 1 line
2.0.3.693.g996b0fd
Re: [PATCH 24/26] cpu_cooling: Store frequencies in descending order
Viresh,
Quoted 34 lines · Viresh Kumar
CPUFreq framework *doesn't* guarantee that frequencies present in cpufreq table will be in ascending or descending order. But
cpu_coolingsomehow assumes that.Probably because most of current users are creating this list from DT, which is done with the help of OPP layer. And OPP layer creates the list in ascending order of frequencies.
But
cpu_coolingcan be used for other platforms too, which don't have frequencies arranged in any order.This patch tries to fix this issue by creating another list of valid frequencies in descending order. Care is also taken to throw warnings for duplicate entries.
Later patches would use it to simplify code.
Signed-off-by Viresh Kumar <[email protected]>--- drivers/thermal/cpu_cooling.c | 41 ++++++++++++++++++++++++++++++++++++++++- 1 file changed, 40 insertions(+), 1 deletion(-)drivers/thermal/cpu_cooling.c +1
-0@@ -65,6 +65,7 @@ struct cpufreq_cooling_device {unsigned int cpufreq_state;unsigned int cpufreq_val;unsigned int max_level; +unsigned int *freq_table;/* In descending order */ struct cpumask allowed_cpus;struct list_head head; };@@ -321,6 +322,20 @@ static struct notifier_block thermal_cpufreq_notifier_block = { .notifier_call = cpufreq_thermal_notifier,
drivers/thermal/cpu_cooling.c static struct notifier_block thermal_cpufreq_notifier_block = { · line 332
Quoted 10 lines
drivers/thermal/cpu_cooling.c +8
-0}; +static unsigned int find_next_max (struct cpufreq_frequency_table *table, +unsigned int prev_max) +{ +struct cpufreq_frequency_table *pos; +unsigned int max =0 ; + +cpufreq_for_each_valid_entry (pos, table) { +if (pos->frequency > max && pos->frequency < prev_max)
What happens if, for some random reason, the cpufreq table is in ascending order and this function is called with prev_max == (unsigned int) -1 ? What would be the returned max?
Quoted 80 lines
drivers/thermal/cpu_cooling.c +31
-1+ max = pos->frequency; + } + +return max; +} +/** * __cpufreq_cooling_register - helper function to create cpufreq cooling device * @np: a valid struct device_node to the cooling device device tree node @@ -343,6 +358,7 @@ __cpufreq_cooling_register(struct device_node *np,struct cpufreq_cooling_device *cpufreq_dev;char dev_name[THERMAL_NAME_LENGTH ];struct cpufreq_frequency_table *pos, *table; +unsigned int freq, i; table =cpufreq_frequency_get_table (cpumask_first (clip_cpus));if (!table) {@@ -358,6 +374,14 @@ __cpufreq_cooling_register(struct device_node *np,cpufreq_for_each_valid_entry (pos, table) cpufreq_dev->max_level++; + cpufreq_dev->freq_table =kmalloc (sizeof (*cpufreq_dev->freq_table) * + cpufreq_dev->max_level,GFP_KERNEL ); +if (!cpufreq_dev->freq_table) { +return ERR_PTR (-ENOMEM ); + cool_dev =ERR_PTR (-ENOMEM ); + goto free_cdev; + } +/* max_level is an index, not a counter */ cpufreq_dev->max_level--;@@ -366,7 +390,7 @@ __cpufreq_cooling_register(struct device_node *np, cpufreq_dev->id =idr_alloc (&cpufreq_idr,NULL ,0 ,0 ,GFP_KERNEL );if (unlikely (cpufreq_dev->id <0 )) { cool_dev =ERR_PTR (cpufreq_dev->id); - goto free_cdev; + goto free_table; } snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",@@ -377,6 +401,18 @@ __cpufreq_cooling_register(struct device_node *np,if (IS_ERR (cool_dev)) goto remove_idr; +/* Fill freq-table in descending order of frequencies */ +for (i =0 , freq =-1 ; i <= cpufreq_dev->max_level; i++) { + freq =find_next_max (table, freq); + cpufreq_dev->freq_table[i] = freq; + +/* Warn for duplicate entries */ +if (!freq) +pr_warn ("%s: table has duplicate entries\n" , __func__); +else +pr_debug ("%s: freq:%u KHz\n" , __func__, freq); + } + cpufreq_dev->cool_dev = cool_dev;INIT_LIST_HEAD (&cpufreq_dev->head);@@ -394,6 +430,8 @@ __cpufreq_cooling_register(struct device_node *np, remove_idr:idr_remove (&cpufreq_idr, cpufreq_dev->id); +free_table: +kfree (cpufreq_dev->freq_table); free_cdev:kfree (cpufreq_dev);@@ -467,6 +505,7 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)thermal_cooling_device_unregister (cpufreq_dev->cool_dev);idr_remove (&cpufreq_idr, cpufreq_dev->id); +kfree (cpufreq_dev->freq_table);kfree (cpufreq_dev); }EXPORT_SYMBOL_GPL (cpufreq_cooling_unregister);Signature · 1 line
2.0.3.693.g996b0fd
Re: [PATCH 24/26] cpu_cooling: Store frequencies in descending order
Quoted 4 lines · Eduardo Valentin
Quoted 4 lines
drivers/thermal/cpu_cooling.c +4
-0+static unsigned int find_next_max (struct cpufreq_frequency_table *table, +unsigned int prev_max) +{ +struct cpufreq_frequency_table *pos;
Quoted 8 lines
drivers/thermal/cpu_cooling.c static struct notifier_block thermal_cpufreq_notifier_block = { · line 332
Quoted 4 lines
drivers/thermal/cpu_cooling.c +4
-0+unsigned int max =0 ; + +cpufreq_for_each_valid_entry (pos, table) { +if (pos->frequency > max && pos->frequency < prev_max)What happens if, for some random reason, the cpufreq table is in ascending order and this function is called with
prev_max== (unsigned int) -1 ? What would be the returned max?
The last frequency of the table, i.e. the max value. What bug did you catch, that I am not able to see..
Re: [PATCH 24/26] cpu_cooling: Store frequencies in descending order
Quoted 15 lines · Viresh Kumar
Quoted 4 lines · Eduardo Valentin
Quoted 4 lines
drivers/thermal/cpu_cooling.c +4
-0+static unsigned int find_next_max (struct cpufreq_frequency_table *table, +unsigned int prev_max) +{ +struct cpufreq_frequency_table *pos;Quoted 8 lines
drivers/thermal/cpu_cooling.c static struct notifier_block thermal_cpufreq_notifier_block = { · line 332
Quoted 4 lines
drivers/thermal/cpu_cooling.c +4
-0+unsigned int max =0 ; + +cpufreq_for_each_valid_entry (pos, table) { +if (pos->frequency > max && pos->frequency < prev_max)What happens if, for some random reason, the cpufreq table is in ascending order and this function is called with
prev_max== (unsigned int) -1 ? What would be the returned max?
Quoted 2 lines
The last frequency of the table, i.e. the max value. What bug did you catch, that I am not able to see..
Well, passing -1 to unsigned int will make it max unsigned int, your function will return the first freq, which in the scenario I gave, it would be the min freq, not the first max, right?
A message that is not in the archive (sent off-list or not yet received): CAKohponw7E9yyvjhP97CzjtcFcq3N+5ysde7DR5q+Nm0s=bKAw@mail.gmail.com
Re: [PATCH 24/26] cpu_cooling: Store frequencies in descending order
Quoted 10 lines · Viresh Kumar
Quoted 2 lines · Eduardo Valentin
Well, passing -1 to unsigned int will make it max unsigned int, your
Yeah, that's what I want.
Quoted 6 lines
Quoted 3 lines
function will return the first freq, which in the scenario I gave, it would be the min freq, not the first max, right?
Are you sure you are reading the code correctly? Try one more time :)
Yeah, the code is correct. I need more coffee probably. :-)
PATCH 25/26 cpu_cooling: Use cpufreq_dev->freq_table for finding level/freq
In reply to Viresh Kumarget_property() was an over complicated beast with BUGs. It used to believe that cpufreq table is present in ascending or descending order, which might not always be true.
Previous patch has created another freq table in descending order for us and we better use it now. With that get_property() simply goes away and another helper get_level() comes in.
--- drivers/thermal/cpu_cooling.c | 96 +++++++------------------------------------ 1 file changed, 14 insertions(+), 82 deletions(-)
drivers/thermal/cpu_cooling.c +14 -82
@@ -80,85 +80,27 @@ static struct cpufreq_cooling_device *notify_device;/* Below code defines functions to be used for cpufreq as cooling device */ -enum cpufreq_cooling_property { -GET_LEVEL , -GET_FREQ , -}; -/** -* get_property - fetch a property of interest for a given cpu. +* get_level: Find the level for a particular frequency * @cpufreq_dev: cpufreq_dev for which the property is required -* @input: query parameter -* @output: query return -* @property: type of query (frequency, level) -* -* This is the common function to -* 1. translate frequency to cooling state -* 2. translate cooling state to frequency +* @freq: Frequency * -* Note that the code may be not in good shape -* but it is written in this way in order to: -* a) reduce duplicate code as most of the code can be shared. -* b) make sure the logic is consistent when translating between -* cooling states and frequencies. -* -* Return: 0 on success, -EINVAL when invalid parameters are passed. +* Returns: level on success, THERMAL_CSTATE_INVALID on error. */ -static int get_property (struct cpufreq_cooling_device *cpufreq_dev, -unsigned long input,unsigned int *output, -enum cpufreq_cooling_property property) +static unsigned long get_level (struct cpufreq_cooling_device *cpufreq_dev, +unsigned int freq) { -int i; -unsigned long level =0 ; -unsigned int freq =CPUFREQ_ENTRY_INVALID ; -int descend =-1 ; -struct cpufreq_frequency_table *pos, *table; - -if (!output) -return -EINVAL ; +unsigned long level; - table =cpufreq_frequency_get_table (cpumask_first (&cpufreq_dev->allowed_cpus)); -if (!table) -return -EINVAL ; +for (level =0 ; level <= cpufreq_dev->max_level; level++) { +if (freq == cpufreq_dev->freq_table[level]) +return level; -cpufreq_for_each_valid_entry (pos, table) { -/* ignore duplicate entry */ -if (freq == pos->frequency) -continue ; - -/* get the frequency order */ -if (freq !=CPUFREQ_ENTRY_INVALID && descend ==-1 ) - descend = freq > pos->frequency; - - freq = pos->frequency; +if (freq > cpufreq_dev->freq_table[level]) +break ; } -if (property ==GET_FREQ ) - level = descend ? input : (cpufreq_dev->max_level - input); - - i =0 ; -cpufreq_for_each_valid_entry (pos, table) { -/* ignore duplicate entry */ -if (freq == pos->frequency) -continue ; - -/* now we have a valid frequency entry */ - freq = pos->frequency; - -if (property ==GET_LEVEL && (unsigned int )input == freq) { -/* get level by frequency */ - *output = descend ? i : (cpufreq_dev->max_level - i); -return 0 ; - } -if (property ==GET_FREQ && level == i) { -/* get frequency by level */ - *output = freq; -return 0 ; - } - i++; - } - -return -EINVAL ; +return THERMAL_CSTATE_INVALID ; }/**
@@ -179,14 +121,8 @@ unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq)mutex_lock (&cooling_cpufreq_lock);list_for_each_entry (cpufreq_dev, &cpufreq_dev_list, head) {if (cpumask_test_cpu (cpu, &cpufreq_dev->allowed_cpus)) { -unsigned int val; -mutex_unlock (&cooling_cpufreq_lock); -if (get_property (cpufreq_dev, (unsigned long )freq, &val, -GET_LEVEL )) -return THERMAL_CSTATE_INVALID ; - -return (unsigned long )val; +return get_level (cpufreq_dev, freq); } }mutex_unlock (&cooling_cpufreq_lock);
@@ -289,16 +225,12 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;unsigned int cpu =cpumask_any (&cpufreq_device->allowed_cpus);unsigned int clip_freq; -int ret =0 ;/* Check if the old cooling action is same as new cooling action */ if (cpufreq_device->cpufreq_state == state)return 0 ; - ret =get_property (cpufreq_device, state, &clip_freq,GET_FREQ ); -if (ret) -return ret; - + clip_freq = cpufreq_device->freq_table[state]; cpufreq_device->cpufreq_state = state; cpufreq_device->cpufreq_val = clip_freq; notify_device = cpufreq_device;
Signature · 1 line
2.0.3.693.g996b0fd
Re: [PATCH 25/26] cpu_cooling: Use cpufreq_dev->freq_table for finding level/freq
Quoted 136 lines · Viresh Kumar
get_property()was an over complicated beast with BUGs. It used to believe that cpufreq table is present in ascending or descending order, which might not always be true.Previous patch has created another freq table in descending order for us and we better use it now. With that
get_property()simply goes away and another helperget_level()comes in.Signed-off-by Viresh Kumar <[email protected]>--- drivers/thermal/cpu_cooling.c | 96 +++++++------------------------------------ 1 file changed, 14 insertions(+), 82 deletions(-)drivers/thermal/cpu_cooling.c +13
-78@@ -80,85 +80,27 @@ static struct cpufreq_cooling_device *notify_device;/* Below code defines functions to be used for cpufreq as cooling device */ -enum cpufreq_cooling_property { -GET_LEVEL , -GET_FREQ , -}; -/** -* get_property - fetch a property of interest for a given cpu. +* get_level: Find the level for a particular frequency * @cpufreq_dev: cpufreq_dev for which the property is required -* @input: query parameter -* @output: query return -* @property: type of query (frequency, level) -* -* This is the common function to -* 1. translate frequency to cooling state -* 2. translate cooling state to frequency +* @freq: Frequency * -* Note that the code may be not in good shape -* but it is written in this way in order to: -* a) reduce duplicate code as most of the code can be shared. -* b) make sure the logic is consistent when translating between -* cooling states and frequencies. -* -* Return: 0 on success, -EINVAL when invalid parameters are passed. +* Returns: level on success, THERMAL_CSTATE_INVALID on error. */ -static int get_property (struct cpufreq_cooling_device *cpufreq_dev, -unsigned long input,unsigned int *output, -enum cpufreq_cooling_property property) +static unsigned long get_level (struct cpufreq_cooling_device *cpufreq_dev, +unsigned int freq) { -int i; -unsigned long level =0 ; -unsigned int freq =CPUFREQ_ENTRY_INVALID ; -int descend =-1 ; -struct cpufreq_frequency_table *pos, *table; - -if (!output) -return -EINVAL ; +unsigned long level; - table =cpufreq_frequency_get_table (cpumask_first (&cpufreq_dev->allowed_cpus)); -if (!table) -return -EINVAL ; +for (level =0 ; level <= cpufreq_dev->max_level; level++) { +if (freq == cpufreq_dev->freq_table[level]) +return level; -cpufreq_for_each_valid_entry (pos, table) { -/* ignore duplicate entry */ -if (freq == pos->frequency) -continue ; - -/* get the frequency order */ -if (freq !=CPUFREQ_ENTRY_INVALID && descend ==-1 ) - descend = freq > pos->frequency; - - freq = pos->frequency; +if (freq > cpufreq_dev->freq_table[level]) +break ; } -if (property ==GET_FREQ ) - level = descend ? input : (cpufreq_dev->max_level - input); - - i =0 ; -cpufreq_for_each_valid_entry (pos, table) { -/* ignore duplicate entry */ -if (freq == pos->frequency) -continue ; - -/* now we have a valid frequency entry */ - freq = pos->frequency; - -if (property ==GET_LEVEL && (unsigned int )input == freq) { -/* get level by frequency */ - *output = descend ? i : (cpufreq_dev->max_level - i); -return 0 ; - } -if (property ==GET_FREQ && level == i) { -/* get frequency by level */ - *output = freq; -return 0 ; - } - i++; - } - -return -EINVAL ; +return THERMAL_CSTATE_INVALID ; }/** @@ -179,14 +121,8 @@ unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq)mutex_lock (&cooling_cpufreq_lock);list_for_each_entry (cpufreq_dev, &cpufreq_dev_list, head) {if (cpumask_test_cpu (cpu, &cpufreq_dev->allowed_cpus)) { -unsigned int val; -mutex_unlock (&cooling_cpufreq_lock); -if (get_property (cpufreq_dev, (unsigned long )freq, &val, -GET_LEVEL )) -return THERMAL_CSTATE_INVALID ; - -return (unsigned long )val; +return get_level (cpufreq_dev, freq); } }mutex_unlock (&cooling_cpufreq_lock);@@ -289,16 +225,12 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;unsigned int cpu =cpumask_any (&cpufreq_device->allowed_cpus);unsigned int clip_freq; -int ret =0 ;
drivers/thermal/cpu_cooling.c static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, · line 233
Quoted 10 lines
drivers/thermal/cpu_cooling.c +1
-4/* Check if the old cooling action is same as new cooling action */ if (cpufreq_device->cpufreq_state == state)return 0 ; - ret =get_property (cpufreq_device, state, &clip_freq,GET_FREQ ); -if (ret) -return ret; - + clip_freq = cpufreq_device->freq_table[state];
There should be some check for valid state here..
Quoted 6 lines
drivers/thermal/cpu_cooling.c +0
-0cpufreq_device->cpufreq_state = state; cpufreq_device->cpufreq_val = clip_freq; notify_device = cpufreq_device;Signature · 1 line
2.0.3.693.g996b0fd
Re: [PATCH 25/26] cpu_cooling: Use cpufreq_dev->freq_table for finding level/freq
Quoted 7 lines · Eduardo Valentin
Review
Quoted 5 lines
(quoted diff) +1
-4- ret = get_property(cpufreq_device, state, &clip_freq, GET_FREQ); - if (ret) - return ret; - + clip_freq = cpufreq_device->freq_table[state];There should be some check for valid state here..
What about this ??
drivers/thermal/cpu_cooling.c +0 -0
@@ -228,6 +228,10 @@ static int cpufreq_set_cur_state(struct
thermal_cooling_device *cdev,
unsigned int cpu = cpumask_any(&cpufreq_device->allowed_cpus);
unsigned int clip_freq;+ /* Request state should be less than max_level */
+ if (WARN_ON(state > cpufreq_device->max_level))
+ return -EINVAL;
+
/* Check if the old cooling action is same as new cooling action */
if (cpufreq_device->cpufreq_state == state)
return 0;Re: [PATCH 25/26] cpu_cooling: Use cpufreq_dev->freq_table for finding level/freq
Quoted 10 lines · Viresh Kumar
Quoted 7 lines · Eduardo Valentin
Review
Quoted 5 lines
(quoted diff) +1
-4- ret = get_property(cpufreq_device, state, &clip_freq, GET_FREQ); - if (ret) - return ret; - + clip_freq = cpufreq_device->freq_table[state];There should be some check for valid state here..
What about this ??
Sounds good to me.
Quoted 17 lines
drivers/thermal/cpu_cooling.c +4
-0@@ -228,6 +228,10 @@ static int cpufreq_set_cur_state(structthermal_cooling_device *cdev, unsigned int cpu = cpumask_any(&cpufreq_device->allowed_cpus);unsigned int clip_freq; +/* Request state should be less than max_level */ +if (WARN_ON (state > cpufreq_device->max_level)) +return -EINVAL ; +/* Check if the old cooling action is same as new cooling action */ if (cpufreq_device->cpufreq_state == state)return 0;
PATCH 26/26 cpu_cooling: update copyright tags
In reply to Viresh KumarAdding my copyright information for two purposes:
- To get cc'd for future patches to review (Only if people read this header while sending mail)
- Have done enough changes to earn a place here?
---
Drop this patch if you didn't like it Eduardo :)
--- drivers/thermal/cpu_cooling.c | 2 ++ 1 file changed, 2 insertions(+)
drivers/thermal/cpu_cooling.c +2 -0
@@ -4,6 +4,8 @@* Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com) * Copyright (C) 2012 Amit Daniel <[email protected]> * +* Copyright (C) 2014 Viresh Kumar <[email protected]> +* * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ * This program is free software; you can redistribute it and/or modify * it under the terms of the GNU General Public License as published by
Signature · 1 line
2.0.3.693.g996b0fd
Re: [PATCH 26/26] cpu_cooling: update copyright tags
Hello Viresh K,
Quoted 3 lines · Viresh Kumar
Adding my copyright information for two purposes:
- To get cc'd for future patches to review (Only if people read this header while sending mail)
For this item, I get_maintainers might copy you due the amount of commit hits, no?
Quoted 5 lines
- Have done enough changes to earn a place here?
Signed-off-by Viresh Kumar <[email protected]>---
Drop this patch if you didn't like it Eduardo :)
I am not against your patch, no.
But, I am probably not the correct person to judge this though. If you get a confirmation from the original copyright holder (amit/samsung), then I am glad to add this.
Quoted 20 lines
--- drivers/thermal/cpu_cooling.c | 2 ++ 1 file changed, 2 insertions(+)drivers/thermal/cpu_cooling.c +2
-0@@ -4,6 +4,8 @@* Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com) * Copyright (C) 2012 Amit Daniel <[email protected]> * +* Copyright (C) 2014 Viresh Kumar <[email protected]> +* * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ * This program is free software; you can redistribute it and/or modify * it under the terms of the GNU General Public License as published by Signature · 1 line
2.0.3.693.g996b0fd
Re: [PATCH 26/26] cpu_cooling: update copyright tags
Quoted 16 lines · Eduardo Valentin
Hello Viresh K,
Quoted 3 lines · Viresh Kumar
Adding my copyright information for two purposes:
- To get cc'd for future patches to review (Only if people read this header while sending mail)For this item, I
get_maintainersmight copy you due the amount of commit hits, no?Quoted 5 lines
- Have done enough changes to earn a place here?
Signed-off-by Viresh Kumar <[email protected]>---
Drop this patch if you didn't like it Eduardo :)
Quoted 5 lines
I am not against your patch, no.
But, I am probably not the correct person to judge this though. If you get a confirmation from the original copyright holder (amit/samsung), then I am glad to add this.
@Amit ?? :)
Quoted 20 lines
Quoted 20 lines
--- drivers/thermal/cpu_cooling.c | 2 ++ 1 file changed, 2 insertions(+)drivers/thermal/cpu_cooling.c +2
-1@@ -4,6 +4,8 @@* Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com) * Copyright (C) 2012 Amit Daniel <[email protected]> * +* Copyright (C) 2014 Viresh Kumar <[email protected]> +* * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ * This program is free software; you can redistribute it and/or modify * it under the terms of the GNU General Public License as published by -- 2.0.3.693.g996b0fd
Re: [PATCH 26/26] cpu_cooling: update copyright tags
Quoted 17 lines · Viresh Kumar
Quoted 16 lines · Eduardo Valentin
Hello Viresh K,
Quoted 3 lines · Viresh Kumar
Adding my copyright information for two purposes:
- To get cc'd for future patches to review (Only if people read this header while sending mail)For this item, I
get_maintainersmight copy you due the amount of commit hits, no?Quoted 5 lines
- Have done enough changes to earn a place here?
Signed-off-by Viresh Kumar <[email protected]>---
Drop this patch if you didn't like it Eduardo :)
Quoted 7 lines
Quoted 5 lines
I am not against your patch, no.
But, I am probably not the correct person to judge this though. If you get a confirmation from the original copyright holder (amit/samsung), then I am glad to add this.
@Amit ?? :)
Yes its fine with me.
Regards,
Amit
Quoted 25 lines
Quoted 5 lines
Quoted 5 lines
--- drivers/thermal/cpu_cooling.c | 2 ++ 1 file changed, 2 insertions(+)Quoted 16 lines
Quoted 14 lines
drivers/thermal/cpu_cooling.c +2
-1@@ -4,6 +4,8 @@* Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com) * Copyright (C) 2012 Amit Daniel <[email protected]> * +* Copyright (C) 2014 Viresh Kumar <[email protected]> +* * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ * This program is free software; you can redistribute it and/or modify * it under the terms of the GNU General Public License as published by -- Quoted 2 lines
2.0.3.693.g996b0fd
--
To unsubscribe from this list: send the line "unsubscribe linux-pm" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html
Hello Viresh,
Quoted 6 lines · Viresh Kumar
Hi Eduardo,
As you know I got into fixing
cpu_cooling.cdue to some cpufreq issues you and Lukasz were struggling with. I found some issues incpu_coolingthen and here are the fixes/cleanups.
Ok. No problem. As I mentioned before, good to have a review in the code by someone with extra experience with cpufreq.
Well, I don't think there was an issue with cpufreq itself. The struggle is with sequencing, specially during booting. The Linux booting sequencing, when it comes to builtin module dependency and probing, does not help much. So, we need to do some tricks with the APIs.
Quoted 5 lines
Sorry for the long list. Haven't broken them into smaller sets as most of the patches are very small, easy to review and inter-dependent. Only few of them should take more time to review. If this doesn't work out, let me know and I will try to send separate inter-dependent sets.
I am fine with this approach, because now you are dealing with a single
target: refactoring cpu cooling code.
Quoted 2 lines
Just apply whatever looks fine and I will update/resend the ones left in V2 if at required.
sure, I will have a look.
Quoted 5 lines
First few are updates to platform drivers. Exynos fails to register after few patches in this series as it doesn't handle -EPROBE_DEFER properly (reported that in reply to your patch as well). Others weren't setting
clip_cpusproperly and are fixed.
OK.
About Exynos, at which point/patch Exynos starts to fail?
As I mentioned in the thread about cpu cooling vs. cpufreq, I prefer to update all users of the updated [of_]cpufreq_cooling_register API, if you don't mind.
Can you please elaborate a little more about how this failure is happening?
Quoted 5 lines
Next ones are cleanups of
cpu_cooling.cto get things properly organized.Let me know if I screwed it up completely.
hehehe.. Ok. I will let you know.
Quoted 55 lines
Tested-on: Exynos5250 (Dual ARM Cortex A15).
Rebased-over: v3.18-rc6
Pushed here:git://git.kernel.org/pub/scm/linux/kernel/git/vireshk/linux.git
thermal/cpu-cooling-fixesCc Amit Daniel Kachhap <[email protected]>Cc Chanwoo Choi <[email protected]>Cc Hongbo Zhang <[email protected]>Cc Kyungmin Park <[email protected]>Cc Lukasz Majewski <[email protected]>Cc Shawn Guo <[email protected]>Viresh Kumar (26):
thermal: db8500: passcpu_present_masktocpufreq_cooling_register()
thermal: imx: passcpu_present_masktocpufreq_cooling_register()
thermal: exynos: passcpu_present_masktocpufreq_cooling_register()
thermal: exynos: Handle -EPROBE_DEFER properly
cpu_cooling: random comment fixups
cpu_cooling: fix doc comment over structcpufreq_cooling_device
cpu_cooling: Add comment to clarify relation between cooling state and
frequency
cpu_cooling: Pass variable instead of its type tosizeof()
cpu_cooling: no need to setcpufreq_stateto zero
cpu_cooling: no need to setcpufreq_devto NULL
cpu_cooling: propagate error returned byidr_alloc()
cpu_cooling: Don't match min/max frequencies for all CPUs on cooling
register
cpu_cooling: don't iterate over allallowed_cpusto update cpufreq
policy
cpu_cooling: Don't checkis_cpufreq_valid()
cpu_cooling: do error handling at the bottom in
__cpufreq_cooling_register()
cpu_cooling: Drop useless locking around idr_alloc/idr_remove
cpu_cooling: Mergecpufreq_apply_cooling()into
cpufreq_set_cur_state()
cpu_cooling: Mergeget_cpu_frequency()intocpufreq_set_cur_state()
cpu_cooling: find max level during device registration
cpu_cooling:get_property()doesn't need to supportGET_MAXLanymore
cpu_cooling: create list ofcpufreq_cooling_devices
cpu_cooling: usecpufreq_dev_listinstead ofcpufreq_dev_count
cpu_cooling: Pass 'cpufreq_dev' toget_property()
cpu_cooling: Store frequencies in descending order
cpu_cooling: Usecpufreq_dev->freq_tablefor finding level/freq
cpu_cooling: update copyright tagsdrivers/thermal/cpu_cooling.c | 405 +++++++++--------------- drivers/thermal/db8500_cpufreq_cooling.c | 5 +- drivers/thermal/imx_thermal.c | 4 +- drivers/thermal/samsung/exynos_thermal_common.c | 11 +- drivers/thermal/samsung/exynos_tmu.c | 4 +- 5 files changed, 153 insertions(+), 276 deletions(-)Signature · 1 line
2.0.3.693.g996b0fd
Quoted 1 line · Eduardo Valentin
About Exynos, at which point/patch Exynos starts to fail?
e2cb864 cpu_cooling: find max level during device registration
Quoted 6 lines
As I mentioned in the thread about cpu cooling vs. cpufreq, I prefer to update all users of the updated [of_]cpufreq_cooling_register API, if you don't mind.
Can you please elaborate a little more about how this failure is happening?
Its the same problem, cpufreq driver isn't ready and cpufreq_frequency_get_table() starts failing :)