Skip to contentSkip to conversation

SIS900 module detects two transceivers, picks the wrong one

DISCUSSION Ion Badulescu 1 participant 1 message Feb 4, 2003 1 message not in the archive

lore
Share & tools
lore
#1 lore raw
In reply to a message not in the archive
Quoted 10 lines · Cameron Goble

I am having trouble with the SIS900 driver module v1.08.04. The module installs correctly and does not return an error, but ... well...

Perhaps dmesg will explain better:

eth0: AMD79C901 HomePNA PHY transceiver found at address 2.
eth0: AMD79C901 10BASE-T PHY transceiver found at address 3.
eth0: using transceiver found at address 2 as default
eth0: SiS 900 PCI Fast Ethernet at 0xec400, IRQ 11, 00:30:67:09:53:81.

Quoted 5 lines

So the network interface is a multi-function device, built onto the motherboard. The driver picks the HomePNA transceiver, but I want to use the 10BASE-T transceiver. Is there an option I can pass, or some code I can edit that force the driver to pick the 10BASE-T transceiver at address 3?

There is no such option, unfortunately. The driver attempts to find a transceiver with a link up, and uses that as a default. If it can't find any, then it defauls to using the HomePNA (type HOME) transceiver.

So you have two choices:

1. make sure the interface is connected to a hub/switch when the driver initializes;

or, if that doesn't work:

2. apply the following patch to the driver:

sis900.c renamed from sis900.c.old +3 -0
@@ -513,6 +513,9 @@
 		u16 mii_status;
 		int i;
 
+		if (phy_addr == 2)
+			continue;
+
 		mii_phy = NULL;
 		for(i = 0; i < 2; i++)
 			mii_status = mdio_read(net_dev, phy_addr, MII_STATUS);

It's a crude hack, but it ought to work on your box.

Ion

Signature · 2 lines
  It is better to keep your mouth shut and be thought a fool,
            than to open it and remove all doubt.