Skip to contentSkip to conversation

What the proper vfio NIC for emulation smmu?

Qemu-arm Jia He 2 participants 3 messages Jun 22, 2018

lore
Share & tools
lore

Jia He

author
#0 lore raw

Hi Eric
I want to test your smmu emulation patchset with vfio-pci ethernet device. Could you kindly give me the NIC type information.
In my test, there is vf probe error for menallox connect 4 NIC and TX Unit hang error for Intel X540 NIC. That's the reason why I ask this question.

Signature · 2 lines
Cheers,
Jia
#1 lore raw

Hello Jia,

Quoted 6 lines · Jia He

Hi Eric
I want to test your smmu emulation patchset with vfio-pci ethernet device. Could you kindly give me the NIC type information.
In my test, there is vf probe error for menallox connect 4 NIC and TX Unit hang error for Intel X540 NIC. That's the reason why I ask this question.

virtual SMMUv3 is not integrated with VFIO and is not planned to be. It was tested with virtio-net-pci (without vhost-net).

With upstream code you should see the following warning:

"SMMUV3 does not support vhost/vfio integration yet: devices of those types will not function properly"

With "[PATCH v3 0/4] ARM SMMUv3: IOTLB Emulation and VHOST Support", vhost-net gets integrated. VFIO won't be integrated either. If vfio-pci device are attempted to be used along with vsmmu, you will get "SMMUv3 does not support notification on MAP: device %s will not function properly"

My attempt to integrate the vsmmu with VFIO in the same manner as intel iommu (using a fake caching mode) was rejected by the kernel maintainer. So for VFIO use case, we need either 2 stage enablement (not implemented yet) or virtio-iommu. I will respin this latter against v0.7 spec probably next week.

Thanks

Eric

author
#2 lore raw

Hi Eric

On 6/22/2018 2:39 PM, Auger Eric Wrote:

Quoted 14 lines

Hello Jia,

Quoted 6 lines · Jia He

Hi Eric
I want to test your smmu emulation patchset with vfio-pci ethernet device. Could you kindly give me the NIC type information.
In my test, there is vf probe error for menallox connect 4 NIC and TX Unit hang error for Intel X540 NIC. That's the reason why I ask this question.

virtual SMMUv3 is not integrated with VFIO and is not planned to be. It was tested with virtio-net-pci (without vhost-net).

With upstream code you should see the following warning:

Quoted 8 lines

"SMMUV3 does not support vhost/vfio integration yet: devices of those types will not function properly"

With "[PATCH v3 0/4] ARM SMMUv3: IOTLB Emulation and VHOST Support", vhost-net gets integrated. VFIO won't be integrated either. If vfio-pci device are attempted to be used along with vsmmu, you will get "SMMUv3 does not support notification on MAP: device %s will not function properly"

Thanks for the information. Actually, I am using your vsmmu-optim-v3 branch. I assumed vfio worked fine since you removed that warning in commit ("hw/arm/smmuv3: Add notifications on invalidation"). Seems I am wrong ;-)

Quoted 6 lines

My attempt to integrate the vsmmu with VFIO in the same manner as intel iommu (using a fake caching mode) was rejected by the kernel maintainer. So for VFIO use case, we need either 2 stage enablement (not implemented yet) or virtio-iommu. I will respin this latter against v0.7 spec probably next week.

Ok. got it, thanks

Quoted 5 lines

Thanks

Eric

Signature · 2 lines
Cheers,
Jia