FailSpare event?
Can someone tell me what this means please? I just received this in an email from one of my servers:
From: mdadm monitoring [root@$DOMAIN.com]
To: root@$DOMAIN.com
Subject: FailSpare event on /dev/md2:$HOST.$DOMAIN.com
This is an automatically generated mail message from mdadm running on $HOST.$DOMAIN.com
A FailSpare event had been detected on md device /dev/md2.
It could be related to component device /dev/sde2.
Faithfully yours, etc.
On this machine I execute:
$ cat /proc/mdstat Personalities : [raid5] [raid4] [raid1] md0 : active raid1 sdf1[2](S) sde1[3](S) sdd1[4](S) sdc1[5](S) sdb1[1] sda1[0] 104320 blocks [2/2] [UU]
md1 : active raid1 sdf3[2](S) sde3[3](S) sdd3[4](S) sdc3[5](S) sdb3[1] sda3[0] 3068288 blocks [2/2] [UU]
md2 : active raid5 sdf2[4] sde2[5](F) sdd2[3] sdc2[2] sdb2[1] sda2[0] 560732160 blocks level 5, 256k chunk, algorithm 2 [5/5] [UUUUU]
unused devices: <none>
Does the email message mean drive sde2[5] has failed? I know the sde2 refers to the second partition of /dev/sde. Here is the partition table
# fdisk -l /dev/sde [root@elo ~]# fdisk -l /dev/sde
Disk /dev/sde: 146.8 GB, 146815733760 bytes
255 heads, 63 sectors/track, 17849 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Device Boot Start End Blocks Id System
/dev/sde1 * 1 13 104391 fd Linux raid autodetect /dev/sde2 14 17465 140183190 fd Linux raid autodetect /dev/sde3 17466 17847 3068415 fd Linux raid autodetect
I have partition 2 of drive sde as one of the raid devices for md. Does the (S) on sde3[2](S) mean the device is a spare for md1 and the same for md0?
Mike
Quoted 3 lines · On Thursday January 11, [email protected] wrote:
Can someone tell me what this means please? I just received this in an email from one of my servers:
....
Quoted 4 lines
A FailSpare event had been detected on md device
/dev/md2.It could be related to component device
/dev/sde2.
It means that mdadm has just noticed that /dev/sde2 is a spare and is faulty.
You would normally expect this if the array is rebuilding a spare and a write to the spare fails however...
Quoted 3 lines
md2 : active raid5 sdf2[4] sde2[5](F) sdd2[3] sdc2[2] sdb2[1] sda2[0] 560732160 blocks level 5, 256k chunk, algorithm 2 [5/5] [UUUUU]
That isn't the case here - your array doesn't need rebuilding. Possible a superblock-update failed. Possibly mdadm only just started monitoring the array and the spare has been faulty for some time.
Quoted 3 lines
Does the email message mean drive sde2[5] has failed? I know the sde2 refers to the second partition of
/dev/sde. Here is the partition table
It means that md thinks sde2 cannot be trusted. To find out why you would need to look at kernel logs for IO errors.
Quoted 4 lines
I have partition 2 of drive sde as one of the raid devices for md. Does the (S) on sde3[2](S) mean the device is a spare for md1 and the same for md0?
Yes, (S) means the device is spare. You don't have (S) next to sde2 on md2 because (F) (failed) overrides (S).
You can tell by the position [5], that it isn't part of the array (being a 5 disk array, the active positions are 0,1,2,3,4).
NeilBrown
Quoted 36 lines · Neil Brown might have
Quoted 3 lines · On Thursday January 11, [email protected] wrote:
Can someone tell me what this means please? I just received this in an email from one of my servers:
....
Quoted 4 lines
A FailSpare event had been detected on md device
/dev/md2.It could be related to component device
/dev/sde2.It means that mdadm has just noticed that
/dev/sde2is a spare and is faulty.You would normally expect this if the array is rebuilding a spare and a write to the spare fails however...
Quoted 3 lines
md2 : active raid5 sdf2[4] sde2[5](F) sdd2[3] sdc2[2] sdb2[1] sda2[0] 560732160 blocks level 5, 256k chunk, algorithm 2 [5/5] [UUUUU]
That isn't the case here - your array doesn't need rebuilding. Possible a superblock-update failed. Possibly mdadm only just started monitoring the array and the spare has been faulty for some time.
Quoted 3 lines
Does the email message mean drive sde2[5] has failed? I know the sde2 refers to the second partition of
/dev/sde. Here is the partition tableIt means that md thinks sde2 cannot be trusted. To find out why you would need to look at kernel logs for IO errors.
Quoted 4 lines
I have partition 2 of drive sde as one of the raid devices for md. Does the (S) on sde3[2](S) mean the device is a spare for md1 and the same for md0?
Quoted 7 lines
Yes, (S) means the device is spare. You don't have (S) next to sde2 on md2 because (F) (failed) overrides (S).
You can tell by the position [5], that it isn't part of the array (being a 5 disk array, the active positions are 0,1,2,3,4).NeilBrown
Thanks for the quick response.
So I'm ok for the moment? Yes, I need to find the error and fix everything back to the (S) state.
The messages in $HOST:/var/log/messages for the time of the email are:
Jan 11 16:04:25 elo kernel: sd 2:0:4:0: SCSI error: return code = 0x8000002 Jan 11 16:04:25 elo kernel: sde: Current: sense key: Hardware Error Jan 11 16:04:25 elo kernel: Additional sense: Internal target failure Jan 11 16:04:25 elo kernel: Info fld=0x10b93c4d Jan 11 16:04:25 elo kernel: end_request: I/O error, dev sde, sector 280575053 Jan 11 16:04:25 elo kernel: raid5: Disk failure on sde2, disabling device. Operation continuing on 5 devices
This is a dell box running Fedora Core with recent patches. It is a production box so I do not patch each night.
On AIX boxes I can blink the drives to identify a bad/failing device. Is there a way to blink the drives in linux?
Mike
Quoted 3 lines · On Thursday January 11, [email protected] wrote:
So I'm ok for the moment? Yes, I need to find the error and fix everything back to the (S) state.
Yes, OK for the moment.
Quoted 9 lines
The messages in $HOST:/var/log/messages for the time of the email are:
Jan 11 16:04:25 elo kernel: sd 2:0:4:0: SCSI error: return code = 0x8000002 Jan 11 16:04:25 elo kernel: sde: Current: sense key: Hardware Error Jan 11 16:04:25 elo kernel: Additional sense: Internal target failure Jan 11 16:04:25 elo kernel: Info fld=0x10b93c4d Jan 11 16:04:25 elo kernel: end_request: I/O error, dev sde, sector 280575053 Jan 11 16:04:25 elo kernel: raid5: Disk failure on sde2, disabling device. Operation continuing on 5 devices
Given the sector number it looks likely that it was a superblock update.
No idea how bad an 'internal target failure' is. Maybe powercycling the drive would 'fix' it, maybe not.
Quoted 3 lines
On AIX boxes I can blink the drives to identify a bad/failing device. Is there a way to blink the drives in linux?
Unfortunately not.
NeilBrown
Quoted 23 lines · Neil Brown might have
Quoted 3 lines · On Thursday January 11, [email protected] wrote:
So I'm ok for the moment? Yes, I need to find the error and fix everything back to the (S) state.
Yes, OK for the moment.
Quoted 9 lines
The messages in $HOST:/var/log/messages for the time of the email are:
Jan 11 16:04:25 elo kernel: sd 2:0:4:0: SCSI error: return code = 0x8000002 Jan 11 16:04:25 elo kernel: sde: Current: sense key: Hardware Error Jan 11 16:04:25 elo kernel: Additional sense: Internal target failure Jan 11 16:04:25 elo kernel: Info fld=0x10b93c4d Jan 11 16:04:25 elo kernel: end_request: I/O error, dev sde, sector 280575053 Jan 11 16:04:25 elo kernel: raid5: Disk failure on sde2, disabling device. Operation continuing on 5 devicesGiven the sector number it looks likely that it was a superblock update.
No idea how bad an 'internal target failure' is. Maybe powercycling the drive would 'fix' it, maybe not.Quoted 1 line
Quoted 7 lines
Quoted 2 lines
On AIX boxes I can blink the drives to identify a bad/failing device. Is there a way to blink the drives in linux?
Unfortunately not.
NeilBrown
I found the smartctl command. I have a 'long' test running in the background. I checked this drive and the other drives. This drive has been used the least (confirms it is a spare?) and is the only one with 'Total uncorrected errors' > 0.
How to determine the error, correct the error, or clear the error?
Mike
[root@$HOST ~]# smartctl -a /dev/sde
smartctl version 5.36 [i686-redhat-linux-gnu] Copyright (C) 2002-6 Bruce Allen Home page is http://smartmontools.sourceforge.net/
Device: SEAGATE ST3146707LC Version: D703
Serial number: 3KS30WY8
Device type: disk
Transport protocol: Parallel SCSI (SPI-4)
Local Time is: Thu Jan 11 17:00:26 2007 CST
Device supports SMART and is Enabled
Temperature Warning Enabled
SMART Health Status: OK
Current Drive Temperature: 48 C Drive Trip Temperature: 68 C Elements in grown defect list: 0
Vendor (Seagate) cache information
Blocks sent to initiator = 66108
Blocks received from initiator = 147374656
Blocks read from cache and sent to initiator = 42215
Number of read and write commands whose size <= segment size = 12635583 Number of read and write commands whose size > segment size = 0
Vendor (Seagate/Hitachi) factory information
number of hours powered up = 3943.42
number of minutes until next internal SMART test = 94
Error counter log:
Errors Corrected by Total Correction Gigabytes Total
ECC rereads/ errors algorithm processed uncorrected
fast | delayed rewrites corrected invocations [10^9 bytes] errors
read: 354 0 0 354 354 0.546 0
write: 0 0 0 0 0 185.871 1Non-medium error count: 0
SMART Self-test log
Num Test Status segment LifeTime LBA_first_err [SK ASC ASQ]
Description number (hours)# 1 Background long Completed, segment failed - 3943 - [- - -]
Long (extended) Self Test duration: 2726 seconds [45.4 minutes]
google "BadBlockHowto"
Any "just google it" response sounds glib, but this is actually how to do it :-)
If you're new to md and mdadm, don't forget to actually remove the drive from the array before you start working on it with 'dd'
-Mike
Quoted 81 lines · Mike
Quoted 18 lines · Neil Brown might have
Quoted 2 lines · On Thursday January 11, [email protected] wrote:
So I'm ok for the moment? Yes, I need to find the error and fix everything back to the (S) state.
Yes, OK for the moment.
Quoted 8 lines
The messages in $HOST:/var/log/messages for the time of the email are:
Jan 11 16:04:25 elo kernel: sd 2:0:4:0: SCSI error: return code = 0x8000002 Jan 11 16:04:25 elo kernel: sde: Current: sense key: Hardware Error Jan 11 16:04:25 elo kernel: Additional sense: Internal target failure Jan 11 16:04:25 elo kernel: Info fld=0x10b93c4d Jan 11 16:04:25 elo kernel: end_request: I/O error, dev sde, sector 280575053 Jan 11 16:04:25 elo kernel: raid5: Disk failure on sde2, disabling device. Operation continuing on 5 devicesGiven the sector number it looks likely that it was a superblock update.
No idea how bad an 'internal target failure' is. Maybe powercycling the drive would 'fix' it, maybe not.Quoted 6 lines
Quoted 2 lines
On AIX boxes I can blink the drives to identify a bad/failing device. Is there a way to blink the drives in linux?
Unfortunately not.
NeilBrown
I found the smartctl command. I have a 'long' test running in the background. I checked this drive and the other drives. This drive has been used the least (confirms it is a spare?) and is the only one with 'Total uncorrected errors' > 0.
How to determine the error, correct the error, or clear the error?
Mike
[root@$HOST ~]# smartctl -a
/dev/sde
smartctl version 5.36 [i686-redhat-linux-gnu] Copyright (C) 2002-6 Bruce Allen Home page is http://smartmontools.sourceforge.net/Device: SEAGATE ST3146707LC Version: D703
Serial number: 3KS30WY8
Device type: disk
Transport protocol: Parallel SCSI (SPI-4)
Local Time is: Thu Jan 11 17:00:26 2007 CST
Device supports SMART and is Enabled
Temperature Warning Enabled
SMART Health Status: OKCurrent Drive Temperature: 48 C Drive Trip Temperature: 68 C Elements in grown defect list: 0Vendor (Seagate) cache information
Blocks sent to initiator = 66108
Blocks received from initiator = 147374656
Blocks read from cache and sent to initiator = 42215
Number of read and write commands whose size <= segment size = 12635583 Number of read and write commands whose size > segment size = 0
Vendor (Seagate/Hitachi) factory information
number of hours powered up = 3943.42
number of minutes until next internal SMART test = 94Error counter log:
Errors Corrected by Total Correction Gigabytes Total ECC rereads/ errors algorithm processed uncorrected fast | delayed rewrites corrected invocations [10^9 bytes] errors read: 354 0 0 354 354 0.546 0 write: 0 0 0 0 0 185.871 1Non-medium error count: 0
SMART Self-test log
Num Test Status segment LifeTime LBA_first_err [SK ASC ASQ] Description number (hours)# 1 Background long Completed, segment failed - 3943 - [- - -]
Long (extended) Self Test duration: 2726 seconds [45.4 minutes]
-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html
Quoted 8 lines · Mike
I found the smartctl command. I have a 'long' test running in the background. I checked this drive and the other drives. This drive has been used the least (confirms it is a spare?) and is the only one with 'Total uncorrected errors' > 0.
How to determine the error, correct the error, or clear the error?
Mike
[cut]
Quoted 6 lines
SMART Self-test log
Num Test Status segment LifeTime LBA_first_err [SK ASC ASQ] Description number (hours)# 1 Background long Completed, segment failed - 3943 - [- - -]
Long (extended) Self Test duration: 2726 seconds [45.4 minutes]
Am I mistaken, or does the above information not say that the long self-test actually failed? If a SMART test fails, that should be sufficient cause to RMA the drive if it's still under warranty.
It might not actually be that surprising to have a largely unused drive fail. I've had a couple drives fail due to what I presume is bearing wear: the drive gradually gets noisy (over many months) and eventually starts having intermittent errors that get more and more frequent. If your drive was spinning while it was a spare, then it would be just as likely to wear out a bad bearing as any of your other drives. Of course, it could be some other problem; that's just an example.
-Corey
2007/1/12, Mike <[email protected]>:
Quoted 1 line
# 1 Background long Completed, segment failed - 3943
This should still be in warranty. Try to get a replacement.
Best
Martin
Quoted 6 lines · Neil Brown
Quoted 2 lines · On Thursday January 11, [email protected] wrote:
Can someone tell me what this means please? I just received this in an email from one of my servers:
....
Same problem here, on different machines. But only with mdadm 2.6, with mdadm 2.5.5 no problems.
First machine sends direct after starting mdadm in monitor mode:
(kernel 2.6.20-rc3)
-----------------------------
event=DeviceDisappeared
mddev=/dev/md1
device=Wrong-Level
Personalities : [linear] [raid0] [raid1] [raid6] [raid5] [raid4] md1 : active raid0 sdb2[1] sda2[0]
3904704 blocks 16k chunks
md2 : active raid0 sdb3[1] sda3[0]
153930112 blocks 16k chunks
md3 : active raid5 sdf1[3] sde1[2] sdd1[1] sdc1[0]
732587712 blocks level 5, 16k chunk, algorithm 2 [4/4] [UUUU]
md0 : active raid1 sdb1[1] sda1[0]
192640 blocks [2/2] [UU]
unused devices: <none>
-----------------------
and a second time for md2.
Then every about 60 sec 4 times
event=SpareActive
mddev=/dev/md3
******************************
Second machine sends about every 60sec 8 messages with:
(kernel 2.6.19.2)
--------------------------
event=SpareActive
mddev=/dev/md0
device=
Personalities : [linear] [raid0] [raid1] [raid10] [raid6] [raid5] [raid4] md1 : active raid1 sdb1[1] sda1[0]
979840 blocks [2/2] [UU]
md3 : active raid5 sdh1[5] sdg1[4] sdf1[3] sde1[2] sdd1[1] sdc1[0]
4899200 blocks level 5, 8k chunk, algorithm 2 [6/6] [UUUUUU]
md2 : active raid5 sdh2[7] sdg2[6] sdf2[5] sde2[4] sdd2[3] sdc2[2] sdb2[1] sda2[0]
6858880 blocks level 5, 4k chunk, algorithm 2 [8/8] [UUUUUUUU]
md0 : active raid5 sdh3[7] sdg3[6] sdf3[5] sde3[4] sdd3[3] sdc3[2] sdb3[1] sda3[0]
235086656 blocks level 5, 16k chunk, algorithm 2 [8/8] [UUUUUUUU]
unused devices: <none>
--------------------------
Both machines had nerver seen any spare device, and there are no failing devices, everything works as expected.
<earny>
On 12 Jan 2007, Ernst Herzberg told this:
Quoted 4 lines
Then every about 60 sec 4 times
event=SpareActive
mddev=/dev/md3
I see exactly this on both my RAID-5 arrays, neither of which have any spare device --- nor have any active devices transitioned to spare (which is what that event is actually supposed to mean).
mdadm-2.6 bug, I fear. I haven't tracked it down yet but will look
shortly: I can't afford to not run mdadm --monitor... odd, that code hasn't changed during 2.6 development.
Signature · 3 lines
`He accused the FSF of being "something of a hypocrit", which shows that he neither understands hypocrisy nor can spell.' --- jimmybgood
Quoted 36 lines · Neil Brown might have
Quoted 3 lines · On Thursday January 11, [email protected] wrote:
Can someone tell me what this means please? I just received this in an email from one of my servers:
....
Quoted 4 lines
A FailSpare event had been detected on md device
/dev/md2.It could be related to component device
/dev/sde2.It means that mdadm has just noticed that
/dev/sde2is a spare and is faulty.You would normally expect this if the array is rebuilding a spare and a write to the spare fails however...
Quoted 3 lines
md2 : active raid5 sdf2[4] sde2[5](F) sdd2[3] sdc2[2] sdb2[1] sda2[0] 560732160 blocks level 5, 256k chunk, algorithm 2 [5/5] [UUUUU]
That isn't the case here - your array doesn't need rebuilding. Possible a superblock-update failed. Possibly mdadm only just started monitoring the array and the spare has been faulty for some time.
Quoted 3 lines
Does the email message mean drive sde2[5] has failed? I know the sde2 refers to the second partition of
/dev/sde. Here is the partition tableIt means that md thinks sde2 cannot be trusted. To find out why you would need to look at kernel logs for IO errors.
Quoted 4 lines
I have partition 2 of drive sde as one of the raid devices for md. Does the (S) on sde3[2](S) mean the device is a spare for md1 and the same for md0?
Quoted 7 lines
Yes, (S) means the device is spare. You don't have (S) next to sde2 on md2 because (F) (failed) overrides (S).
You can tell by the position [5], that it isn't part of the array (being a 5 disk array, the active positions are 0,1,2,3,4).NeilBrown
I have cleared the error by:
# mdadm --manage /dev/md2 -f /dev/sde2 ( make sure it has failed ) # mdadm --manage /dev/md2 -r /dev/sde2 ( remove from the array ) # mdadm --manage /dev/md2 -a /dev/sde2 ( add the device back to the array ) # mdadm --detail /dev/md2 ( verify there are no faults and the array knows about the spare )
On 13 Jan 2007, [email protected] spake thusly:
Quoted 9 lines
On 12 Jan 2007, Ernst Herzberg told this:
Quoted 4 lines
Then every about 60 sec 4 times
event=SpareActive
mddev=/dev/md3I see exactly this on both my RAID-5 arrays, neither of which have any spare device --- nor have any active devices transitioned to spare (which is what that event is actually supposed to mean).
Hm, the manual says that it means that a spare has transitioned to active (which seems more likely). Perhaps the comment at line 82 of Monitor.c is wrong, or I just don't understand what a `reverse transition' is supposed to be.
Signature · 3 lines
`He accused the FSF of being "something of a hypocrit", which shows that he neither understands hypocrisy nor can spell.' --- jimmybgood
On 13 Jan 2007, [email protected] uttered the following:
Quoted 9 lines
On 12 Jan 2007, Ernst Herzberg told this:
Quoted 4 lines
Then every about 60 sec 4 times
event=SpareActive
mddev=/dev/md3I see exactly this on both my RAID-5 arrays, neither of which have any spare device --- nor have any active devices transitioned to spare (which is what that event is actually supposed to mean).
One oddity has already come to light. My /proc/mdstat says
md2 : active raid5 sdb7[0] hda5[3] sda7[1]
19631104 blocks super 1.2 level 5, 64k chunk, algorithm 2 [3/3] [UUU]
md1 : active raid5 sda6[0] hdc5[3] sdb6[1]
76807296 blocks super 1.2 level 5, 64k chunk, algorithm 2 [3/3] [UUU]
hda5 and hdc5 look odd. Indeed, --examine says
Number Major Minor RaidDevice State
0 8 6 0 active sync /dev/sda6
1 8 22 1 active sync /dev/sdb6
3 22 5 2 active sync /dev/hdc5
Number Major Minor RaidDevice State
0 8 23 0 active sync /dev/sdb7
1 8 7 1 active sync /dev/sda7
3 3 5 2 active sync /dev/hda5
0, 1, and *3*. Where has number 2 gone? (And how does Number' differ from RaidDevice'? Why have both?)
Signature · 3 lines
`He accused the FSF of being "something of a hypocrit", which shows that he neither understands hypocrisy nor can spell.' --- jimmybgood
On 13 Jan 2007, [email protected] uttered the following:
Quoted 3 lines
mdadm-2.6 bug, I fear. I haven't tracked it down yet but will look
shortly: I can't afford to not run mdadm --monitor... odd, that code hasn't changed during 2.6 development.
Whoo! Compile Monitor.c without optimization and the problem goes away.
Hunting: maybe it's a compiler bug (anyone not using GCC 4.1.1 seeing this?), maybe mdadm is tripping undefined behaviour somewhere...
Signature · 3 lines
`He accused the FSF of being "something of a hypocrit", which shows that he neither understands hypocrisy nor can spell.' --- jimmybgood
Quoted 9 lines · On Sunday January 14, [email protected] wrote:
On 13 Jan 2007, [email protected] uttered the following:
Quoted 3 lines
mdadm-2.6 bug, I fear. I haven't tracked it down yet but will look
shortly: I can't afford to not run mdadm --monitor... odd, that code hasn't changed during 2.6 development.Whoo! Compile
Monitor.cwithout optimization and the problem goes away.Hunting: maybe it's a compiler bug (anyone not using GCC 4.1.1 seeing this?), maybe mdadm is tripping undefined behaviour somewhere...
Probably....
A quick look suggests that the following patch might make a difference, but there is more to it than that. I think there are subtle differences due to the use of version-1 superblocks. That might be just another one-line change, but I want to make sure first.
Thanks,
NeilBrown
### Diffstat output
./Monitor.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
Monitor.c +1 -1
@@ -383,7 +383,7 @@ int Monitor(mddev_dev_t devlist, )alert ("SpareActive" , dev, dv, mailaddr, mailfrom, alert_cmd, dosyslog); } - st->devstate[i] = disc.state; + st->devstate[i] = newstate; st->devid[i] =makedev (disc.major, disc.minor); } st->active = array.active_disks;
On 15 Jan 2007, Bill Davidsen told this:
Quoted 11 lines
Quoted 10 lines · Nix
Number Major Minor RaidDevice State
0 8 6 0 active sync/dev/sda6
1 8 22 1 active sync/dev/sdb6
3 22 5 2 active sync/dev/hdc5Number Major Minor RaidDevice State
0 8 23 0 active sync/dev/sdb7
1 8 7 1 active sync/dev/sda7
3 3 5 2 active sync/dev/hda5
Quoted 8 lines
Quoted 4 lines
0, 1, and *3*. Where has number 2 gone? (And how does
Number' differ fromRaidDevice'? Why have both?)Did you ever move the data to these drives from another? I think this is what you see when you migrate by adding a drive as a spare, then mark an existing drive as failed, so the data is rebuilt on the new drive. Was there ever a device 2?
Nope. These arrays were created in one lump and never had a spare.
Plenty of pvmoves have happened on them, but that's *inside* the arrays, of course...
Signature · 3 lines
`He accused the FSF of being "something of a hypocrit", which shows that he neither understands hypocrisy nor can spell.' --- jimmybgood
On 14 Jan 2007, Neil Brown told this:
Quoted 4 lines
A quick look suggests that the following patch might make a difference, but there is more to it than that. I think there are subtle differences due to the use of version-1 superblocks. That might be just another one-line change, but I want to make sure first.
Well, that certainly made that warning go away. I don't have any actually-failed disks, so I can't tell if it would *ever* warn anymore ;)
... actually, it just picked up some monthly array check activity:
Jan 15 20:03:17 loki daemon warning: mdadm: Rebuild20 event detected on md device /dev/md2
So it looks like it works perfectly well now.
(Looking at the code, yeah, without that change it'll never remember state changes at all!)
One bit of residue from the state before this patch remains on line 352, where you initialize disc.state and then never use it for anything...
Signature · 3 lines
`He accused the FSF of being "something of a hypocrit", which shows that he neither understands hypocrisy nor can spell.' --- jimmybgood