Skip to contentSkip to conversation

workqueue: Fixes for v7.4-rc2

GIT PULL New Tejun Heo 2 participants 7 messages Nov 15 – Nov 23

Subsystems (2)
lore
Share & tools
lore

Tejun Heo

author maintainer
#0 lore raw

Hello,

The following changes since commit d89e1d186ec9271bf78e62771779e9fc03bf0fc3:

Merge tag 'fscrypt-for-linus' of git://git.kernel.org/pub/scm/fs/fscrypt/linux (2026-10-29 14:00:23 -1000)

are available in the Git repository at:

https://git.kernel.org/pub/scm/linux/kernel/git/tj/wq.git tags/wq-for-7.4-rc2-fixes

for you to fetch changes up to c7d64f52bffaca093acfb34277877138f6ec243a:

workqueue: Fix drain_workqueue() missing work items chained across pwqs (2026-11-02 08:06:21 -1000)

----------------------------------------------------------------
workqueue: Fixes for v7.4-rc2

- Draining a workqueue could return while a work item queued by another work item was still pending, making workqueue destruction warn and leak the workqueue.

----------------------------------------------------------------
Tejun Heo (1):
workqueue: Fix drain_workqueue() missing work items chained across pwqs

 kernel/workqueue.c | 68 ++++++++++++++++++++++++++++++++++++++++--------------
 1 file changed, 51 insertions(+), 17 deletions(-)
Signature · 1 line
tejun
#1 lore raw
Quoted 4 lines · Tejun Heo

- Draining a workqueue could return while a work item queued by another work item was still pending, making workqueue destruction warn and leak the workqueue.

Why is this re-creating - badly - the existing sequence counter code?

Not only does it do the memory barriers by hand - possibly getting them wrong, but it seems actively broken.

There's a reason proper sequence counters have that "odd/even" rule, and a writer increments the sequence counter *twice* - once when it starts the modification and once when it is done.

As far as I can tell, your "fix" is still broken:

drain_workqueue:

        mutex_lock(&wq->mutex);
        if (!wq->nr_drainers++)
                wq->flags |= __WQ_DRAINING;
        mutex_unlock(&wq->mutex);

        seq = atomic_read(&wq->drain_seq);

__queue_work:

        if (unlikely(wq->flags & (__WQ_DESTROYING | __WQ_DRAINING))) {
   ...
                smp_mb__before_atomic();
                atomic_inc(&wq->drain_seq);
                smp_mb__after_atomic();

but what if __queue_work() was called before __WQ_DRAINING was set and is running concurrently and never incremented the sequence number?

Of even if it *did* increment the sequence number, what keeps it from doing that *before* the atomic_read() in drain_workqueue() and then

Either way drain_workqueue() never sees that drain_seq change, and thinks everythings is fine, even though __queue_work added an entry?

Is there some other serialization that I'm missing?

Anyway, sequence numbers almost never work with a single write, exactly beause the single write is itself then not ordered with the changes that the writer does (ie the sequence point update happens before them or after them, but either way the reader might miss the sequence number update, becuase it's not atomic wrt the actual change it is supposed to be about.

The actual 8real* sequence numbers we have do that two-step change exactly because of these issues. The writer increments once before it starts writing, and increments it again after it is done. That way the reader actually can check whether something changed (an odd value means that change is happening and needs retrying regardless - which is why read_seqcount_begin(() will loop on odd numbers)

It is possible that I'm missing something that makes your ad-hoc version ok, but this really does look just plain broken.

I pulled it and then unpulled it, waiting for explanations.

Linus

author maintainer
#2 lore raw

Hello, Linus.

Quoted 7 lines · Linus Torvalds
Quoted 4 lines · Tejun Heo

- Draining a workqueue could return while a work item queued by another work item was still pending, making workqueue destruction warn and leak the workqueue.

Why is this re-creating - badly - the existing sequence counter code?

I was trying to plug the hole minimally and it just didn't trigger "oh this is seqcount".

Quoted 30 lines

Not only does it do the memory barriers by hand - possibly getting them wrong, but it seems actively broken.

There's a reason proper sequence counters have that "odd/even" rule, and a writer increments the sequence counter *twice* - once when it starts the modification and once when it is done.

As far as I can tell, your "fix" is still broken:

drain_workqueue:

        mutex_lock(&wq->mutex);
        if (!wq->nr_drainers++)
                wq->flags |= __WQ_DRAINING;
        mutex_unlock(&wq->mutex);

        seq = atomic_read(&wq->drain_seq);

__queue_work:

        if (unlikely(wq->flags & (__WQ_DESTROYING | __WQ_DRAINING))) {
   ...
                smp_mb__before_atomic();
                atomic_inc(&wq->drain_seq);
                smp_mb__after_atomic();

but what if __queue_work() was called before __WQ_DRAINING was set and is running concurrently and never incremented the sequence number?

Quoted 7 lines

Of even if it *did* increment the sequence number, what keeps it from doing that *before* the atomic_read() in drain_workqueue() and then

Either way drain_workqueue() never sees that drain_seq change, and thinks everythings is fine, even though __queue_work added an entry?

Is there some other serialization that I'm missing?

Hmm... so, draining looks like this:

        set DRAINING;
        read seq;
        flush wq:
                for each pwq:
                        flush them;
        for each pwq:
                lock and check whether empty;
        if not drained or seq bumped, try again;

and the queueing side tests DRAINING and incs the seq while the queueing work item is still in flight on its pwq. The chained insertion is under the pool lock.

Any work item that hasn't seen DRAINING or inc'd the seq before draining reads it should be visible to the flush wq step, and by the time flush finishes, all the immediate chained work items it queued should be visible to the following pwq empty test step.

A chained work item queued after the flush started saw DRAINING and inc'd the seq after the read, so if it chains further and finishes before the empty test, the seq check catches it.

Quoted 14 lines

Anyway, sequence numbers almost never work with a single write, exactly beause the single write is itself then not ordered with the changes that the writer does (ie the sequence point update happens before them or after them, but either way the reader might miss the sequence number update, becuase it's not atomic wrt the actual change it is supposed to be about.

The actual 8real* sequence numbers we have do that two-step change exactly because of these issues. The writer increments once before it starts writing, and increments it again after it is done. That way the reader actually can check whether something changed (an odd value means that change is happening and needs retrying regardless - which is why read_seqcount_begin(() will loop on odd numbers)

Quoted 4 lines

It is possible that I'm missing something that makes your ad-hoc version ok, but this really does look just plain broken.

I pulled it and then unpulled it, waiting for explanations.

I don't think it's broken but it is adhoc and difficult to get one's head around including my own. It'd be a lot simpler w/ seqcount. I'm traveling this week, so might be slower but will redo it.

Thanks.

Signature · 1 line
tejun
#3 lore raw
Quoted 12 lines · Tejun Heo

Hmm... so, draining looks like this:

        set DRAINING;
        read seq;
        flush wq:
                for each pwq:
                        flush them;
        for each pwq:
                lock and check whether empty;
        if not drained or seq bumped, try again;
Quoted 3 lines

and the queueing side tests DRAINING and incs the seq while the queueing work item is still in flight on its pwq. The chained insertion is under the pool lock.

So now I don't have the patch in my tree any more (I could fetch it again, but I'm lazy), but from memory and my lkimited quoting the queueing side only incremented the seq number *if* it saw DRAINING.

And that seemed to be the biggest issue.

If the queueing side did *not* see DRAINING, it also wouldn't increment the sequence number, and it also didn't have any memory barriers.

So it looked to me like the code basically fell back to the exact old sequence that the patch claimed to fix: if the queuing side missed seeing that "set DRAINING" part, all the changes in the commit became no-ops. Yes, the draining side would re-read the sequence counter and retry, but the sequence counter didn't actually change because the queueing side wouldn't be updating it.

But I'll freely admit that I really only looked at the "shape" of the code, and it all felt wrong to me. This was not some deep-dive understanding, it was a "this doesn't feel right".

Quoted 3 lines

I don't think it's broken but it is adhoc and difficult to get one's head around including my own. It'd be a lot simpler w/ seqcount. I'm traveling this week, so might be slower but will redo it.

Thanks.

The main problem with a seqcount might be performance - I'm assuming you tried to avoid the write for the common cases. I assume *draining* is the slow and uncommon case, and typically *that* side is where you want to do the writer side of the seqcount, and then the fast and common case is the one that wants to do the sequence number read.

So maybe the generic seqcount code isn't what you want, and maybe your current code is the right thing, and my "it feels wrong" is the wrong reaction.

Put another way: you should also just feel free to tell me that I was wrong, and explain *why* it all works the way you did it. Use small words and call me names.

Linus

#4 lore raw
Quoted 4 lines · Linus Torvalds

But I'll freely admit that I really only looked at the "shape" of the code, and it all felt wrong to me. This was not some deep-dive understanding, it was a "this doesn't feel right".

I think your original patch worked, and the memory barriers were what I really ended up hating. But that's solvable by just doing the counter inside the pool lock instead.

And that means that my suggestion of using the generic seqcount code was barking up the wrong tree too: I reacted to the ad-hoc memory barriers and the fact that you used a sequence counter, not to the actual code and problem.

And then the drain_workqueue() logic can just be changed a bit: after draining, go back and do kind of what you used to do, except don't look at just whether the pwq is empty, but also at whether new work was started?

A *UNTESTED* patch like this, in other words...

Linus

---

 kernel/workqueue.c | 47 ++++++++++++++++++++++++++++++++++++-----------
 1 file changed, 36 insertions(+), 11 deletions(-)
kernel/workqueue.c +36 -11
index af845214e78b..31d376656504 100644
@@ -281,6 +281,7 @@ struct pool_workqueue {
 	int			total_in_flight; /* L: sum of nr_in_flight[] */
 	int			nr_in_flight[WORK_NR_COLORS];
 						/* L: nr of in_flight works */
+	unsigned long		nr_started;	/* L: see drain_workqueue() */
 	struct list_head	flush_node;	/* FN: node on wq_flush_pnode->pwqs */
 	bool			plugged;	/* L: execution suspended */
 
@@ -3455,6 +3456,7 @@ __acquires(&pool->lock)
 	 */
 	set_work_pool_and_clear_pending(work, pool->id, pool_offq_flags(pool));
 
+	pwq->nr_started++;
 	pwq->stats[PWQ_STAT_STARTED]++;
 
 	rcu_read_lock();
@@ -4449,6 +4451,29 @@ void __flush_workqueue(struct workqueue_struct *wq)
 }
 EXPORT_SYMBOL(__flush_workqueue);
 
+/* 0 if any pwq is busy, otherwise 2 * sum of nr_started + 1 */
+static unsigned long pwqs_nr_started(struct workqueue_struct *wq)
+{
+	struct pool_workqueue *pwq;
+	unsigned long sum = 0;
+
+	lockdep_assert_held(&wq->mutex);
+
+	for_each_pwq(pwq, wq) {
+		bool empty;
+
+		raw_spin_lock_irq(&pwq->pool->lock);
+		empty = pwq_is_empty(pwq);
+		sum += pwq->nr_started;
+		raw_spin_unlock_irq(&pwq->pool->lock);
+
+		if (!empty)
+			return 0;
+	}
+
+	return 2 * sum + 1;
+}
+
 /**
  * drain_workqueue - drain a workqueue
  * @wq: workqueue to drain
@@ -4462,8 +4487,8 @@ EXPORT_SYMBOL(__flush_workqueue);
  */
 void drain_workqueue(struct workqueue_struct *wq)
 {
+	unsigned long started;
 	unsigned int flush_cnt = 0;
-	struct pool_workqueue *pwq;
 
 	/*
 	 * __queue_work() needs to test whether there are drainers, is much
@@ -4479,16 +4504,16 @@ void drain_workqueue(struct workqueue_struct *wq)
 
 	mutex_lock(&wq->mutex);
 
-	for_each_pwq(pwq, wq) {
-		bool drained;
-
-		raw_spin_lock_irq(&pwq->pool->lock);
-		drained = pwq_is_empty(pwq);
-		raw_spin_unlock_irq(&pwq->pool->lock);
-
-		if (drained)
-			continue;
-
+	/*
+	 * A pass isn't atomic across pwqs, so a chained work item can land on
+	 * a pwq it already found empty. Anything slipping past the second pass
+	 * needs a work item that was in flight at its pwq's first check, or
+	 * that started between its pwq's two checks. The first makes the first
+	 * pass fail, the second changes nr_started. wq->mutex keeps the set of
+	 * pwqs stable across both passes.
+	 */
+	started = pwqs_nr_started(wq);
+	if (!started || pwqs_nr_started(wq) != started) {
 		if (++flush_cnt == 10 ||
 		    (flush_cnt % 100 == 0 && flush_cnt <= 1000))
 			pr_warn("workqueue %s: %s() isn't complete after %u tries\n",
author maintainer
#5 lore raw

Hello,

On Wed, Nov 18, 2026 at 11:27:38AM -0600, Linus Torvalds wrote:
...

Quoted 4 lines

And then the drain_workqueue() logic can just be changed a bit: after draining, go back and do kind of what you used to do, except don't look at just whether the pwq is empty, but also at whether new work was started?

Yeah, this is a lot simpler. Instead of trying to detect events across flush, just make sure that empty test actually can test empty.

Quoted 1 line

A *UNTESTED* patch like this, in other words...

This looks correct to me but lemme do some testing on it.

Thanks.

Signature · 1 line
tejun
author maintainer
#6 lore raw

PATCH 1/1 workqueue: Fix drain_workqueue() missing work items chained across pwqs

In reply to Linus Torvalds

From: Linus Torvalds <[email protected]>

drain_workqueue() flushes the workqueue, then checks each pwq under its pool's lock and returns once a pass finds every pwq empty. Only chained queueing is allowed meanwhile, and a chained work item can land on a pwq other than the one the queueing work item is executing on. The pass misses it when:

1. The pass finds pwq A empty.
2. A work item executing on pwq B queues a work item on pwq A.
3. The work item on pwq B finishes.
4. The pass finds pwq B empty.

drain_workqueue() returns with the work item on pwq A pending, and destroy_workqueue() can then trip WARN_ON(pwq_busy()) and leak the workqueue.

Add pwq->nr_started, which counts the work items a pwq has started executing, and check the pwqs twice after each flush. The drain is complete only if both passes find every pwq empty and no work item started in between. The counter is updated and read under pool->lock, and the queueing path is not touched.

Verified with reproducers of both shapes: self-requeueing work items on an unbound workqueue and chained queue_work_on() of another work item on a per-cpu workqueue.

Fixes c8efcc258946 ("workqueue: allow chained queueing during destruction")
Cc [email protected] # v2.6.38+
[ tj: Wrote the description and updated the pwqs_nr_started() comment. ]

---
Applied to wq/for-7.4-fixes, replacing c7d64f52bffa ("workqueue: Fix drain_workqueue() missing work items chained across pwqs") from the pull request.

 kernel/workqueue.c | 51 ++++++++++++++++++++++++++++++++++++----------
 1 file changed, 40 insertions(+), 11 deletions(-)
kernel/workqueue.c +40 -11
index f2e8071a6f4e..08046ff0d697 100644
@@ -281,6 +281,7 @@ struct pool_workqueue {
 	int			total_in_flight; /* L: sum of nr_in_flight[] */
 	int			nr_in_flight[WORK_NR_COLORS];
 						/* L: nr of in_flight works */
+	unsigned long		nr_started;	/* L: see drain_workqueue() */
 	struct list_head	flush_node;	/* FN: node on wq_flush_pnode->pwqs */
 	bool			plugged;	/* L: execution suspended */
 
@@ -3455,6 +3456,7 @@ __acquires(&pool->lock)
 	 */
 	set_work_pool_and_clear_pending(work, pool->id, pool_offq_flags(pool));
 
+	pwq->nr_started++;
 	pwq->stats[PWQ_STAT_STARTED]++;
 
 	rcu_read_lock();
@@ -4449,6 +4451,33 @@ void __flush_workqueue(struct workqueue_struct *wq)
 }
 EXPORT_SYMBOL(__flush_workqueue);
 
+/*
+ * Return 0 if any pwq of @wq is busy. Otherwise, return the sum of nr_started
+ * of all pwqs encoded as 2 * sum + 1, which is always odd, so that 0 can only
+ * mean busy.
+ */
+static unsigned long pwqs_nr_started(struct workqueue_struct *wq)
+{
+	struct pool_workqueue *pwq;
+	unsigned long sum = 0;
+
+	lockdep_assert_held(&wq->mutex);
+
+	for_each_pwq(pwq, wq) {
+		bool empty;
+
+		raw_spin_lock_irq(&pwq->pool->lock);
+		empty = pwq_is_empty(pwq);
+		sum += pwq->nr_started;
+		raw_spin_unlock_irq(&pwq->pool->lock);
+
+		if (!empty)
+			return 0;
+	}
+
+	return 2 * sum + 1;
+}
+
 /**
  * drain_workqueue - drain a workqueue
  * @wq: workqueue to drain
@@ -4462,8 +4491,8 @@ EXPORT_SYMBOL(__flush_workqueue);
  */
 void drain_workqueue(struct workqueue_struct *wq)
 {
+	unsigned long started;
 	unsigned int flush_cnt = 0;
-	struct pool_workqueue *pwq;
 
 	/*
 	 * __queue_work() needs to test whether there are drainers, is much
@@ -4479,16 +4508,16 @@ void drain_workqueue(struct workqueue_struct *wq)
 
 	mutex_lock(&wq->mutex);
 
-	for_each_pwq(pwq, wq) {
-		bool drained;
-
-		raw_spin_lock_irq(&pwq->pool->lock);
-		drained = pwq_is_empty(pwq);
-		raw_spin_unlock_irq(&pwq->pool->lock);
-
-		if (drained)
-			continue;
-
+	/*
+	 * A pass isn't atomic across pwqs, so a chained work item can land on
+	 * a pwq it already found empty. Anything slipping past the second pass
+	 * needs a work item that was in flight at its pwq's first check, or
+	 * that started between its pwq's two checks. The first makes the first
+	 * pass fail, the second changes nr_started. wq->mutex keeps the set of
+	 * pwqs stable across both passes.
+	 */
+	started = pwqs_nr_started(wq);
+	if (!started || pwqs_nr_started(wq) != started) {
 		if (++flush_cnt == 10 ||
 		    (flush_cnt % 100 == 0 && flush_cnt <= 1000))
 			pr_warn("workqueue %s: %s() isn't complete after %u tries\n",
Signature · 1 line
2.56.1