raid5 oopses on 2nd failed device
hi!
it looks like raid5 is buggy. as 2nd device is failed, I got oops. it's BUG at raid5.c:212. this is because sh->written[N] isn't NULL. raid5d thread try to handle this stripe, but following condition skip handling:
/* might be able to return some write requests if the parity block
* is safe, or on a failed drive
*/
bh = sh->bh_cache[sh->pd_idx];
if ( written &&
( (conf->disks[sh->pd_idx].operational && !buffer_locked(bh) && buffer_uptodate(bh))
|| (failed == 1 && failed_num == sh->pd_idx))
) {I suggest to fail requests which can't be returned as successful.
with best regards
drivers/md/raid5.c +13 -1
@@ -938,7 +938,19 @@ static void handle_stripe(struct stripe_ } } } - + +/* if already written requests can't be returned as successful fail them */ +if (failed >1 && written) { +for (i=disks; i--; ) { +if (sh->bh_written[i]) written--; +while ((bh = sh->bh_written[i])) { + sh->bh_written[i] = bh->b_reqnext; + bh->b_reqnext = return_fail; + return_fail = bh; + } + } + } +/* Now we might consider reading some blocks, either to check/generate * parity, or to satisfy requests */