Skip to contentSkip to conversation

hwmon: (scpi-hwmon) shows the negative temperature properly

PATCH Guenter Roeck 1 participant 1 message May 24, 2021 1 message not in the archive Hardware monitoring

lore
Share & tools
lore

A message that is not in the archive (sent off-list or not yet received): [email protected]

Guenter Roeck

author maintainer
#1 lore raw
Quoted 11 lines · 卢日文
Quoted 7 lines

What did you test ? Did you really manage to run the system in such an environment ?

'value' is declared as u64, not as s64.
I can not evaluate what the firmware actually reports. The API reports an u64. Do you have any evidence for your claim that it returns a signed value under any circumstances ?

Yes, the comsumer of my company test their machines in harsh environment including the very low temperature.

I tried to look this up, but the ARM developer documentation is vague when it comes to describing the content of sensor readings. Is it documented somewhere that the temperature is actually returned as signed value ? If so, can you point me to it ?

I'll need to have some confirmation that this is legitimate.

Quoted 8 lines

The first picture below shows that the temp returned as a unsigned value when it is a negtive value with sensors tool.

And the second picture shows the real value after applyed my changes in scpi hwmon.

1234.jpg

2345.jpg

Pictures are not attached.

Quoted 9 lines
Quoted 7 lines

On top of that, your change affects not only temperature values, but all attributes. It is highly unlikely that the firmware would report negative power or energy values. It is, however, possible that energy values have the upper bit of an u64 set after a long runtime. Your change would result in a negative energy value if that is ever the case.

Quoted 4 lines

Sorry for not considered this situation before.

But I think it can be judged by sensor->info.class. if it is TEMPERATURE situation, return the value as a signed value,  otherwise it returned as a unsigned value.

Correct.

Thanks,
Guenter