Refactor thermal pressure update to avoid code duplication
Subsystems (8)
Lukasz Luba
reviewerv2 cover Refactor thermal pressure update to avoid code duplication
Hi all,
This patch set v2 aims to refactor the thermal pressure update code. There are already two clients which do similar thing:
convert the capped frequency value into the capacity of affected CPU and call the 'set' function to store the reduced capacity into the per-cpu variable.
There might be more than two of these users. In near future it will be scmi-cpufreq driver, which receives notification from FW about reduced frequency due to thermal. Other vendors might follow. Let's avoid code duplication and potential conversion bugs. Move the conversion code into the arch_topology.c where the capacity calculation setup code and thermal pressure sit.
Apart from that $subject patches, there is one patch (3/5) which fixes issue in qcom-cpufreq-hw.c when the thermal pressure is not updated for offline CPUs. It's similar fix that has been merged recently for cpufreq_cooling.c:2ad8ccc17d1e4270cf65a3f2
Changes:
v2:
- added Reviewed-by from Thara for patch 3/5
- changed the doxygen comment and used mult_frac() according to Thara's suggestion in patch 1/5
v1 -> [1]
Regards,
Lukasz Luba
[1] https://lore.kernel.org/linux-pm/[email protected]/
Lukasz Luba (5):
arch_topology: Introduce thermal pressure update function
thermal: cpufreq_cooling: Use new thermal pressure update function
cpufreq: qcom-cpufreq-hw: Update offline CPUs per-cpu thermal pressure
cpufreq: qcom-cpufreq-hw: Use new thermal pressure update function
arch_topology: Remove unused topology_set_thermal_pressure() and
related
arch/arm/include/asm/topology.h | 2 +- arch/arm64/include/asm/topology.h | 2 +- drivers/base/arch_topology.c | 35 +++++++++++++++++++++++++++---- drivers/cpufreq/qcom-cpufreq-hw.c | 14 +++++-------- drivers/thermal/cpufreq_cooling.c | 6 +----- include/linux/arch_topology.h | 4 ++-- include/linux/sched/topology.h | 6 +++--- init/Kconfig | 2 +- 8 files changed, 45 insertions(+), 26 deletions(-)
Signature · 1 line
2.17.1
Lukasz Luba
reviewerPATCH v2 1/5 arch_topology: Introduce thermal pressure update function
The thermal pressure is a mechanism which is used for providing information about reduced CPU performance to the scheduler. Usually code has to convert the value from frequency units into capacity units, which are understandable by the scheduler. Create a common conversion code which can be just used via a handy API.
--- arch/arm/include/asm/topology.h | 1 + arch/arm64/include/asm/topology.h | 1 + drivers/base/arch_topology.c | 36 ++++++++++++++++++++++++++++++- include/linux/arch_topology.h | 3 +++ include/linux/sched/topology.h | 7 ++++++ 5 files changed, 47 insertions(+), 1 deletion(-)
arch/arm/include/asm/topology.h +1 -0
@@ -24,6 +24,7 @@/* Replace task scheduler's default thermal pressure API */ #define arch_scale_thermal_pressure topology_get_thermal_pressure#define arch_set_thermal_pressure topology_set_thermal_pressure +#define arch_thermal_pressure_update topology_thermal_pressure_update#else
arch/arm64/include/asm/topology.h +1 -0
@@ -33,6 +33,7 @@ void update_freq_counters_refs(void);/* Replace task scheduler's default thermal pressure API */ #define arch_scale_thermal_pressure topology_get_thermal_pressure#define arch_set_thermal_pressure topology_set_thermal_pressure +#define arch_thermal_pressure_update topology_thermal_pressure_update#include <asm-generic/topology.h>
drivers/base/arch_topology.c +35 -1
@@ -25,6 +25,7 @@ static DEFINE_PER_CPU(struct scale_freq_data __rcu *, sft_data);static struct cpumask scale_freq_counters_mask;static bool scale_freq_invariant; +static DEFINE_PER_CPU(u32, freq_factor) = 1;static bool supports_scale_freq_counters (const struct cpumask *cpus) {
@@ -168,6 +169,40 @@ void topology_set_thermal_pressure(const struct cpumask *cpus, }EXPORT_SYMBOL_GPL (topology_set_thermal_pressure); +/** +* topology_thermal_pressure_update() - Update thermal pressure for CPUs +* @cpus : The related CPUs for which capacity has been reduced +* @capped_freq : The maximum allowed frequency that CPUs can run at +* +* Update the value of thermal pressure for all @cpus in the mask. The +* cpumask should include all (online+offline) affected CPUs, to avoid +* operating on stale data when hot-plug is used for some CPUs. The +* @capped_freq must be less or equal to the max possible frequency and +* reflects the currently allowed max CPUs frequency due to thermal capping. +* The @capped_freq must be provided in kHz. +*/ +void topology_thermal_pressure_update (const struct cpumask *cpus, +unsigned long capped_freq) +{ +unsigned long max_capacity, capacity; +int cpu; + +if (!cpus) +return ; + + cpu =cpumask_first (cpus); + max_capacity =arch_scale_cpu_capacity (cpu); + +/* Convert to MHz scale which is used in 'freq_factor' */ + capped_freq /=1000 ; + + capacity =mult_frac (capped_freq, max_capacity, +per_cpu (freq_factor, cpu)); + +arch_set_thermal_pressure (cpus, max_capacity - capacity); +} +EXPORT_SYMBOL_GPL (topology_thermal_pressure_update); +static ssize_t cpu_capacity_show (struct device *dev,struct device_attribute *attr,char *buf)
@@ -220,7 +255,6 @@ static void update_topology_flags_workfn(struct work_struct *work) update_topology =0 ; } -static DEFINE_PER_CPU(u32, freq_factor) = 1;static u32 *raw_capacity;static int free_raw_capacity (void )
include/linux/arch_topology.h +3 -0
@@ -59,6 +59,9 @@ static inline unsigned long topology_get_thermal_pressure(int cpu)void topology_set_thermal_pressure (const struct cpumask *cpus,unsigned long th_pressure); +void topology_thermal_pressure_update (const struct cpumask *cpus, +unsigned long capped_freq); +struct cpu_topology {int thread_id;int core_id;
include/linux/sched/topology.h +7 -0
@@ -266,6 +266,13 @@ void arch_set_thermal_pressure(const struct cpumask *cpus, { }#endif +#ifndef arch_thermal_pressure_update +static __always_inline +void arch_thermal_pressure_update(const struct cpumask *cpus, +unsigned long capped_frequency) +{ } +#endif +static inline int task_node (const struct task_struct *p) {return cpu_to_node (task_cpu (p));
Signature · 1 line
2.17.1
Re: [PATCH v2 1/5] arch_topology: Introduce thermal pressure update function
Quoted 32 lines · Lukasz Luba
The thermal pressure is a mechanism which is used for providing information about reduced CPU performance to the scheduler. Usually code has to convert the value from frequency units into capacity units, which are understandable by the scheduler. Create a common conversion code which can be just used via a handy API.
Signed-off-by Lukasz Luba <[email protected]>--- arch/arm/include/asm/topology.h | 1 + arch/arm64/include/asm/topology.h | 1 + drivers/base/arch_topology.c | 36 ++++++++++++++++++++++++++++++- include/linux/arch_topology.h | 3 +++ include/linux/sched/topology.h | 7 ++++++ 5 files changed, 47 insertions(+), 1 deletion(-)arch/arm/include/asm/topology.h +1
-0@@ -24,6 +24,7 @@/* Replace task scheduler's default thermal pressure API */ #define arch_scale_thermal_pressure topology_get_thermal_pressure#define arch_set_thermal_pressure topology_set_thermal_pressure +#define arch_thermal_pressure_update topology_thermal_pressure_update#else arch/arm64/include/asm/topology.h +0
-0
arch/arm64/include/asm/topology.h void update_freq_counters_refs(void); · line 36
Quoted 4 lines
arch/arm64/include/asm/topology.h +1
-0@@ -33,6 +33,7 @@ void update_freq_counters_refs(void);/* Replace task scheduler's default thermal pressure API */ #define arch_scale_thermal_pressure topology_get_thermal_pressure#define arch_set_thermal_pressure topology_set_thermal_pressure +#define arch_thermal_pressure_update topology_thermal_pressure_update
s/thermal_pressure_update/update_thermal_pressure ?
The scheme seems to be {arch|topology}_*foo*_thermal_pressure
But ...
Quoted 24 lines
arch/arm64/include/asm/topology.h +0
-0#include <asm-generic/topology.h> drivers/base/arch_topology.c +6
-0@@ -25,6 +25,7 @@ static DEFINE_PER_CPU(struct scale_freq_data __rcu *, sft_data);static struct cpumask scale_freq_counters_mask;static bool scale_freq_invariant; +static DEFINE_PER_CPU(u32, freq_factor) = 1;static bool supports_scale_freq_counters (const struct cpumask *cpus) {@@ -168,6 +169,40 @@ void topology_set_thermal_pressure(const struct cpumask *cpus, }EXPORT_SYMBOL_GPL (topology_set_thermal_pressure); +/** +* topology_thermal_pressure_update() - Update thermal pressure for CPUs +* @cpus : The related CPUs for which capacity has been reduced +* @capped_freq : The maximum allowed frequency that CPUs can run at +*
drivers/base/arch_topology.c void topology_set_thermal_pressure(const struct cpumask *cpus, · line 186
Quoted 10 lines
drivers/base/arch_topology.c +10
-0+* Update the value of thermal pressure for all @cpus in the mask. The +* cpumask should include all (online+offline) affected CPUs, to avoid +* operating on stale data when hot-plug is used for some CPUs. The +* @capped_freq must be less or equal to the max possible frequency and +* reflects the currently allowed max CPUs frequency due to thermal capping. +* The @capped_freq must be provided in kHz. +*/ +void topology_thermal_pressure_update (const struct cpumask *cpus, +unsigned long capped_freq) +{
... why not just s/unsigned long th_pressure/unsigned long capped_freq in existing topology_set_thermal_pressure() and move code the frequency/capacity conversion in there? The patch set will become considerably smaller.
void topology_set_thermal_pressure(const struct cpumask *cpus,
- unsigned long th_pressure)
+ unsigned long capped_freq)
{
+ unsigned long max_capacity, capacity;
int cpu;- for_each_cpu(cpu, cpus)
- WRITE_ONCE(per_cpu(thermal_pressure, cpu), th_pressure);
+ if (!cpus)
+ return;
+
+ cpu = cpumask_first(cpus);
+ max_capacity = arch_scale_cpu_capacity(cpu);
+
+ /* Convert to MHz scale which is used in 'freq_factor' */
+ capped_freq /= 1000;
+
+ capacity = mult_frac(capped_freq, max_capacity,
+ per_cpu(freq_factor, cpu));
+
+ for_each_cpu(cpu, cpus) {
+ WRITE_ONCE(per_cpu(thermal_pressure, cpu),
+ max_capacity - capacity);
+ }
} EXPORT_SYMBOL_GPL(topology_set_thermal_pressure);
And a user like [drivers/thermal/cpufreq_cooling.c] can call arch_set_thermal_pressure(cpus, frequency).
[...]
Lukasz Luba
reviewerRe: [PATCH v2 1/5] arch_topology: Introduce thermal pressure update function
Hi Dietmar,
Thank you for having a look at this.
Quoted 1 line · Dietmar Eggemann
On 15/10/2021 16:45, Lukasz Luba wrote:
[snip]
Quoted 3 lines
Quoted 1 line
+#define
arch_thermal_pressure_updatetopology_thermal_pressure_updates/thermal_pressure_update/update_thermal_pressure ?
I can reorder that naming.
Quoted 6 lines
The scheme seems to be {arch|topology}_*foo*_thermal_pressure
But ...
Quoted 1 line
[snip]
Quoted 8 lines
drivers/base/arch_topology.c void topology_set_thermal_pressure(const struct cpumask *cpus, · line 186
Quoted 3 lines
drivers/base/arch_topology.c +3
-0+void topology_thermal_pressure_update (const struct cpumask *cpus, +unsigned long capped_freq) +{... why not just s/unsigned long th_pressure/unsigned long
capped_freqin existingtopology_set_thermal_pressure()and move code the frequency/capacity conversion in there? The patch set will become considerably smaller.
I've been trying to avoid confusion when changing actually behavior of the API function. Thus, introducing new would IMO opinion make sure the old 'set' function was expecting proper pressure value, while the new 'update' expects frequency.
I agree that the patch set would be smaller in that case, but I'm not sure if that would not hide some issues. This one would definitely break compilation of some vendor modules (or drivers queuing or under review), not silently passing them through (with wrong argument).
Quoted 4 lines
void topology_set_thermal_pressure(const struct cpumask *cpus,
(quoted diff) +1
-1- unsigned long th_pressure) + unsigned long capped_freq)
[snip]
Quoted 7 lines
EXPORT_SYMBOL_GPL(topology_set_thermal_pressure);And a user like [
drivers/thermal/cpufreq_cooling.c] can callarch_set_thermal_pressure(cpus, frequency).[...]
I'm not sure if that is a safe way.
Regards,
Lukasz
Re: [PATCH v2 1/5] arch_topology: Introduce thermal pressure update function
Quoted 6 lines · Lukasz Luba
Hi Dietmar,
Thank you for having a look at this.
Quoted 1 line · Dietmar Eggemann
On 15/10/2021 16:45, Lukasz Luba wrote:
[...]
Quoted 14 lines
Quoted 8 lines
drivers/base/arch_topology.c void topology_set_thermal_pressure(const struct cpumask *cpus, · line 186
Quoted 3 lines
drivers/base/arch_topology.c +3
-0+void topology_thermal_pressure_update (const struct cpumask *cpus, + unsigned long capped_freq) +{... why not just s/unsigned long th_pressure/unsigned long
capped_freqin existingtopology_set_thermal_pressure()and move code the frequency/capacity conversion in there? The patch set will become considerably smaller.I've been trying to avoid confusion when changing actually behavior of the API function. Thus, introducing new would IMO opinion make sure the old 'set' function was expecting proper pressure value, while the new 'update' expects frequency.
Quoted 5 lines
I agree that the patch set would be smaller in that case, but I'm not sure if that would not hide some issues. This one would definitely break compilation of some vendor modules (or drivers queuing or under review), not silently passing them through (with wrong argument).
I see, since the parameter type list would stay the same, this could potentially happen.
[...]
Re: [PATCH v2 1/5] arch_topology: Introduce thermal pressure update function
In reply to Lukasz LubaQuoted 1 line · Lukasz Luba
arch/arm64/include/asm/topology.h +0
-0
[..]
Quoted 4 lines
+/**
+ *topology_thermal_pressure_update()- Update thermal pressure for CPUs
+ * @cpus : The related CPUs for which capacity has been reduced
+ * @capped_freq : The maximum allowed frequency that CPUs can run at
I know this matches what I see in e.g. the Qualcomm cpufreq hw driver, but in what cases will @capped_freq differ from cpufreq_get_hw_max_freq(cpumask_first(cpus))?
Regards,
Bjorn
Quoted 41 lines
+ *
+ * Update the value of thermal pressure for all @cpus in the mask. The
+ * cpumask should include all (online+offline) affected CPUs, to avoid
+ * operating on stale data when hot-plug is used for some CPUs. The
+ * @capped_freq must be less or equal to the max possible frequency and
+ * reflects the currently allowed max CPUs frequency due to thermal capping.
+ * The @capped_freq must be provided in kHz.
+ */arch/arm64/include/asm/topology.h +22
-1+void topology_thermal_pressure_update (const struct cpumask *cpus, +unsigned long capped_freq) +{ +unsigned long max_capacity, capacity; +int cpu; + +if (!cpus) +return ; + + cpu =cpumask_first (cpus); + max_capacity =arch_scale_cpu_capacity (cpu); + +/* Convert to MHz scale which is used in 'freq_factor' */ + capped_freq /=1000 ; + + capacity =mult_frac (capped_freq, max_capacity, +per_cpu (freq_factor, cpu)); + +arch_set_thermal_pressure (cpus, max_capacity - capacity); +} +EXPORT_SYMBOL_GPL (topology_thermal_pressure_update); +static ssize_t cpu_capacity_show (struct device *dev,struct device_attribute *attr,char *buf)@@ -220,7 +255,6 @@ static void update_topology_flags_workfn(struct work_struct *work) update_topology =0 ; } -static DEFINE_PER_CPU(u32, freq_factor) = 1;static u32 *raw_capacity;static int free_raw_capacity (void )
Lukasz Luba
reviewerRe: [PATCH v2 1/5] arch_topology: Introduce thermal pressure update function
Quoted 11 lines · Bjorn Andersson
Quoted 1 line · Lukasz Luba
arch/arm64/include/asm/topology.h +0
-0[..]
Quoted 4 lines
+/**
+ *topology_thermal_pressure_update()- Update thermal pressure for CPUs
+ * @cpus : The related CPUs for which capacity has been reduced
+ * @capped_freq : The maximum allowed frequency that CPUs can run atI know this matches what I see in e.g. the Qualcomm cpufreq hw driver, but in what cases will @capped_freq differ from cpufreq_get_hw_max_freq(cpumask_first(cpus))?
The @capped_freq is the maximum allowed frequency value due to thermal reasons, which will always be lower or equal to the value returned by cpufreq_get_hw_max_freq()
(effectively: 'policy->cpuinfo.max_freq').
We limit the frequency (and voltage) of CPU to reduce power (and heat) in the passive cooling system. That information is important to us, because scheduler needs to know how fast the CPU can go. It cannot assume that the speed is always 'policy->cpuinfo.max_freq'. Often it's less then that at heavy load or GPU heavy load (the same SoC).
Regards,
Lukasz
Re: [PATCH v2 1/5] arch_topology: Introduce thermal pressure update function
Quoted 11 lines · Lukasz Luba
Quoted 8 lines · Bjorn Andersson
Quoted 1 line · Lukasz Luba
arch/arm64/include/asm/topology.h +0
-0[..]
Quoted 4 lines
+/**
+ *topology_thermal_pressure_update()- Update thermal pressure for CPUs
+ * @cpus : The related CPUs for which capacity has been reduced
+ * @capped_freq : The maximum allowed frequency that CPUs can run at
Quoted 9 lines
Quoted 3 lines
I know this matches what I see in e.g. the Qualcomm cpufreq hw driver, but in what cases will @capped_freq differ from cpufreq_get_hw_max_freq(cpumask_first(cpus))?
The @capped_freq is the maximum allowed frequency value due to thermal reasons, which will always be lower or equal to the value returned by
cpufreq_get_hw_max_freq()
(effectively: 'policy->cpuinfo.max_freq').
Read patch 3 and 4 again and now this makes sense to me.
Thanks,
Bjorn
Quoted 8 lines
We limit the frequency (and voltage) of CPU to reduce power (and heat) in the passive cooling system. That information is important to us, because scheduler needs to know how fast the CPU can go. It cannot assume that the speed is always '
policy->cpuinfo.max_freq'. Often it's less then that at heavy load or GPU heavy load (the same SoC).Regards,
Lukasz
Viresh Kumar
maintainerRe: [PATCH v2 1/5] arch_topology: Introduce thermal pressure update function
In reply to Lukasz LubaQuoted 4 lines · Lukasz Luba
+/**
+ *topology_thermal_pressure_update()- Update thermal pressure for CPUs
+ * @cpus : The related CPUs for which capacity has been reduced
+ * @capped_freq : The maximum allowed frequency that CPUs can run at
Maybe replace tabs with spaces here ?
Quoted 8 lines
+ *
+ * Update the value of thermal pressure for all @cpus in the mask. The
+ * cpumask should include all (online+offline) affected CPUs, to avoid
+ * operating on stale data when hot-plug is used for some CPUs. The
+ * @capped_freq must be less or equal to the max possible frequency and
+ * reflects the currently allowed max CPUs frequency due to thermal capping.
+ * The @capped_freq must be provided in kHz.
+ */
drivers/base/arch_topology.c void topology_set_thermal_pressure(const struct cpumask *cpus, · line 190
Quoted 7 lines
drivers/base/arch_topology.c +7
-0+void topology_thermal_pressure_update (const struct cpumask *cpus, +unsigned long capped_freq) +{ +unsigned long max_capacity, capacity; +int cpu; + +if (!cpus)
I will drop this and let the kernel crash :)
drivers/base/arch_topology.c void topology_set_thermal_pressure(const struct cpumask *cpus, · line 197
Quoted 7 lines
drivers/base/arch_topology.c +7
-0+return ; + + cpu =cpumask_first (cpus); + max_capacity =arch_scale_cpu_capacity (cpu); + +/* Convert to MHz scale which is used in 'freq_factor' */ + capped_freq /=1000 ;
We should make sure capped_freq > freq_factor and WARN if not. This will also get rid of similar checks at the users.
Quoted 7 lines
drivers/base/arch_topology.c +7
-0+ + capacity =mult_frac (capped_freq, max_capacity, +per_cpu (freq_factor, cpu)); + +arch_set_thermal_pressure (cpus, max_capacity - capacity); +} +EXPORT_SYMBOL_GPL (topology_thermal_pressure_update);
Signature · 1 line
viresh
Lukasz Luba
reviewerRe: [PATCH v2 1/5] arch_topology: Introduce thermal pressure update function
Quoted 7 lines · Viresh Kumar
Quoted 4 lines · Lukasz Luba
+/**
+ *topology_thermal_pressure_update()- Update thermal pressure for CPUs
+ * @cpus : The related CPUs for which capacity has been reduced
+ * @capped_freq : The maximum allowed frequency that CPUs can run atMaybe replace tabs with spaces here ?
Sure
Quoted 10 lines
Quoted 10 lines
+ *
+ * Update the value of thermal pressure for all @cpus in the mask. The
+ * cpumask should include all (online+offline) affected CPUs, to avoid
+ * operating on stale data when hot-plug is used for some CPUs. The
+ * @capped_freq must be less or equal to the max possible frequency and
+ * reflects the currently allowed max CPUs frequency due to thermal capping.
+ * The @capped_freq must be provided in kHz.
+ */
+void topology_thermal_pressure_update(const struct cpumask *cpus,
Quoted 8 lines
drivers/base/arch_topology.c void topology_set_thermal_pressure(const struct cpumask *cpus, · line 190
Quoted 6 lines
drivers/base/arch_topology.c +6
-0+ unsigned long capped_freq) +{ +unsigned long max_capacity, capacity; +int cpu; + +if (!cpus)I will drop this and let the kernel crash :)
OK :)
Quoted 11 lines
drivers/base/arch_topology.c void topology_set_thermal_pressure(const struct cpumask *cpus, · line 197
Quoted 8 lines
drivers/base/arch_topology.c +7
-0+return ; + + cpu =cpumask_first (cpus); + max_capacity =arch_scale_cpu_capacity (cpu); + +/* Convert to MHz scale which is used in 'freq_factor' */ + capped_freq /=1000 ;We should make sure
capped_freq>freq_factorand WARN if not. This will also get rid of similar checks at the users.
OK, I'll change that.
Thank you for the review.
Regards,
Lukasz
Lukasz Luba
reviewerPATCH v2 2/5 thermal: cpufreq_cooling: Use new thermal pressure update function
In reply to Lukasz LubaThermal pressure provides a new API, which allows to use CPU frequency as an argument. That removes the need of local conversion to capacity. Use this new function and remove old conversion code.
--- drivers/thermal/cpufreq_cooling.c | 6 +----- 1 file changed, 1 insertion(+), 5 deletions(-)
drivers/thermal/cpufreq_cooling.c +1 -5
@@ -462,7 +462,6 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;struct cpumask *cpus;unsigned int frequency; -unsigned long max_capacity, capacity;int ret;/* Request state should be less than max_level */
@@ -479,10 +478,7 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,if (ret >=0 ) { cpufreq_cdev->cpufreq_state = state; cpus = cpufreq_cdev->policy->related_cpus; - max_capacity =arch_scale_cpu_capacity (cpumask_first (cpus)); - capacity = frequency * max_capacity; - capacity /= cpufreq_cdev->policy->cpuinfo.max_freq; -arch_set_thermal_pressure (cpus, max_capacity - capacity); +arch_thermal_pressure_update (cpus, frequency); ret =0 ; }
Signature · 1 line
2.17.1
Re: [PATCH v2 2/5] thermal: cpufreq_cooling: Use new thermal pressure update function
On 15/10/2021 16:45, Lukasz Luba wrote:
[...]
drivers/thermal/cpufreq_cooling.c static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, · line 484
Quoted 7 lines
drivers/thermal/cpufreq_cooling.c +0
-3@@ -479,10 +478,7 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,if (ret >=0 ) { cpufreq_cdev->cpufreq_state = state; cpus = cpufreq_cdev->policy->related_cpus; - max_capacity =arch_scale_cpu_capacity (cpumask_first (cpus)); - capacity = frequency * max_capacity; - capacity /= cpufreq_cdev->policy->cpuinfo.max_freq;
Took me a while to realize that cpufreq_cdev->policy->cpuinfo.max_freq is 1000 * per_cpu(freq_factor, cpu), the latter being used now in arch_thermal_pressure_update(). Maybe worth mentioning in the patch header?
Lukasz Luba
reviewerRe: [PATCH v2 2/5] thermal: cpufreq_cooling: Use new thermal pressure update function
Quoted 4 lines · Dietmar Eggemann
On 15/10/2021 16:45, Lukasz Luba wrote:
[...]
Quoted 12 lines
drivers/thermal/cpufreq_cooling.c static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, · line 484
Quoted 7 lines
drivers/thermal/cpufreq_cooling.c +0
-3@@ -479,10 +478,7 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,if (ret >=0 ) { cpufreq_cdev->cpufreq_state = state; cpus = cpufreq_cdev->policy->related_cpus; - max_capacity =arch_scale_cpu_capacity (cpumask_first (cpus)); - capacity = frequency * max_capacity; - capacity /= cpufreq_cdev->policy->cpuinfo.max_freq;Took me a while to realize that
cpufreq_cdev->policy->cpuinfo.max_freqis 1000 *per_cpu(freq_factor, cpu), the latter being used now inarch_thermal_pressure_update(). Maybe worth mentioning in the patch header?
OK, I will put that information into the patch description in the next version.
Lukasz Luba
reviewerPATCH v2 3/5 cpufreq: qcom-cpufreq-hw: Update offline CPUs per-cpu thermal pressure
In reply to Lukasz LubaThe thermal pressure signal gives information to the scheduler about reduced CPU capacity due to thermal. It is based on a value stored in a per-cpu 'thermal_pressure' variable. The online CPUs will get the new value there, while the offline won't. Unfortunately, when the CPU is back online, the value read from per-cpu variable might be wrong (stale data). This might affect the scheduler decisions, since it sees the CPU capacity differently than what is actually available.
Fix it by making sure that all online+offline CPUs would get the proper value in their per-cpu variable when there is throttling or throttling is removed.
--- drivers/cpufreq/qcom-cpufreq-hw.c | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-)
drivers/cpufreq/qcom-cpufreq-hw.c +2 -1
@@ -304,7 +304,8 @@ static void qcom_lmh_dcvs_notify(struct qcom_cpufreq_data *data)if (capacity > max_capacity) capacity = max_capacity; -arch_set_thermal_pressure (policy->cpus, max_capacity - capacity); +arch_set_thermal_pressure (policy->related_cpus, + max_capacity - capacity);/* * In the unlikely case policy is unregistered do not enable
Signature · 1 line
2.17.1
Lukasz Luba
reviewerPATCH v2 4/5 cpufreq: qcom-cpufreq-hw: Use new thermal pressure update function
In reply to Lukasz LubaThermal pressure provides a new API, which allows to use CPU frequency as an argument. That removes the need of local conversion to capacity. Use this new API and remove old local conversion code.
--- drivers/cpufreq/qcom-cpufreq-hw.c | 15 +++++---------- 1 file changed, 5 insertions(+), 10 deletions(-)
drivers/cpufreq/qcom-cpufreq-hw.c +5 -10
@@ -275,10 +275,10 @@ static unsigned int qcom_lmh_get_throttle_freq(struct qcom_cpufreq_data *data)static void qcom_lmh_dcvs_notify (struct qcom_cpufreq_data *data) { -unsigned long max_capacity, capacity, freq_hz, throttled_freq;struct cpufreq_policy *policy = data->policy;int cpu =cpumask_first (policy->cpus);struct device *dev =get_cpu_device (cpu); +unsigned long freq_hz, throttled_freq;struct dev_pm_opp *opp;unsigned int freq;
@@ -295,17 +295,12 @@ static void qcom_lmh_dcvs_notify(struct qcom_cpufreq_data *data) throttled_freq = freq_hz /HZ_PER_KHZ ; -/* Update thermal pressure */ - - max_capacity =arch_scale_cpu_capacity (cpu); - capacity =mult_frac (max_capacity, throttled_freq, policy->cpuinfo.max_freq); -/* Don't pass boost capacity to scheduler */ -if (capacity > max_capacity) - capacity = max_capacity; +if (throttled_freq > policy->cpuinfo.max_freq) + throttled_freq = policy->cpuinfo.max_freq; -arch_set_thermal_pressure (policy->related_cpus, - max_capacity - capacity); +/* Update thermal pressure */ +arch_thermal_pressure_update (policy->related_cpus, throttled_freq);/* * In the unlikely case policy is unregistered do not enable
Signature · 1 line
2.17.1
Lukasz Luba
reviewerPATCH v2 5/5 arch_topology: Remove unused topology_set_thermal_pressure() and related
In reply to Lukasz LubaThere is no need of this function (and related) since code has been converted to use the new arch_thermal_pressure_update() API. The old code can be removed.
--- arch/arm/include/asm/topology.h | 1 - arch/arm64/include/asm/topology.h | 1 - drivers/base/arch_topology.c | 17 +++++------------ include/linux/arch_topology.h | 3 --- include/linux/sched/topology.h | 7 ------- init/Kconfig | 2 +- 6 files changed, 6 insertions(+), 25 deletions(-)
arch/arm/include/asm/topology.h +0 -1
@@ -23,7 +23,6 @@/* Replace task scheduler's default thermal pressure API */ #define arch_scale_thermal_pressure topology_get_thermal_pressure -#define arch_set_thermal_pressure topology_set_thermal_pressure#define arch_thermal_pressure_update topology_thermal_pressure_update#else
arch/arm64/include/asm/topology.h +0 -1
@@ -32,7 +32,6 @@ void update_freq_counters_refs(void);/* Replace task scheduler's default thermal pressure API */ #define arch_scale_thermal_pressure topology_get_thermal_pressure -#define arch_set_thermal_pressure topology_set_thermal_pressure#define arch_thermal_pressure_update topology_thermal_pressure_update#include <asm-generic/topology.h>
drivers/base/arch_topology.c +5 -12
@@ -159,16 +159,6 @@ void topology_set_cpu_scale(unsigned int cpu, unsigned long capacity) DEFINE_PER_CPU(unsigned long, thermal_pressure); -void topology_set_thermal_pressure (const struct cpumask *cpus, -unsigned long th_pressure) -{ -int cpu; - -for_each_cpu (cpu, cpus) -WRITE_ONCE (per_cpu (thermal_pressure, cpu), th_pressure); -} -EXPORT_SYMBOL_GPL (topology_set_thermal_pressure); -/** * topology_thermal_pressure_update() - Update thermal pressure for CPUs * @cpus : The related CPUs for which capacity has been reduced
@@ -184,7 +174,7 @@ EXPORT_SYMBOL_GPL(topology_set_thermal_pressure);void topology_thermal_pressure_update (const struct cpumask *cpus,unsigned long capped_freq) { -unsigned long max_capacity, capacity; +unsigned long max_capacity, capacity, th_pressure;int cpu;if (!cpus)
@@ -199,7 +189,10 @@ void topology_thermal_pressure_update(const struct cpumask *cpus, capacity =mult_frac (capped_freq, max_capacity,per_cpu (freq_factor, cpu)); -arch_set_thermal_pressure (cpus, max_capacity - capacity); + th_pressure = max_capacity - capacity; + +for_each_cpu (cpu, cpus) +WRITE_ONCE (per_cpu (thermal_pressure, cpu), th_pressure); }EXPORT_SYMBOL_GPL (topology_thermal_pressure_update);
include/linux/arch_topology.h +0 -3
@@ -56,9 +56,6 @@ static inline unsigned long topology_get_thermal_pressure(int cpu)return per_cpu (thermal_pressure, cpu); } -void topology_set_thermal_pressure (const struct cpumask *cpus, -unsigned long th_pressure); -void topology_thermal_pressure_update (const struct cpumask *cpus,unsigned long capped_freq);
include/linux/sched/topology.h +0 -7
@@ -259,13 +259,6 @@ unsigned long arch_scale_thermal_pressure(int cpu) }#endif -#ifndef arch_set_thermal_pressure -static __always_inline -void arch_set_thermal_pressure(const struct cpumask *cpus, -unsigned long th_pressure) -{ } -#endif -#ifndef arch_thermal_pressure_update static __always_inline void arch_thermal_pressure_update(const struct cpumask *cpus,
init/Kconfig +1 -1
@@ -559,7 +559,7 @@ config SCHED_THERMAL_PRESSURE i.e. put less load on throttled CPUs than on non/less throttled ones. This requires the architecture to implement - arch_set_thermal_pressure() and arch_scale_thermal_pressure(). + arch_thermal_pressure_update() and arch_scale_thermal_pressure(). config BSD_PROCESS_ACCT bool "BSD Process Accounting"
Signature · 1 line
2.17.1
Lukasz Luba
reviewerQuoted 20 lines · Lukasz Luba
Hi all,
This patch set v2 aims to refactor the thermal pressure update code. There are already two clients which do similar thing:
convert the capped frequency value into the capacity of affected CPU and call the 'set' function to store the reduced capacity into the per-cpu variable.
There might be more than two of these users. In near future it will be scmi-cpufreq driver, which receives notification from FW about reduced frequency due to thermal. Other vendors might follow. Let's avoid code duplication and potential conversion bugs. Move the conversion code into thearch_topology.cwhere the capacity calculation setup code and thermal pressure sit.Apart from that $subject patches, there is one patch (3/5) which fixes issue in
qcom-cpufreq-hw.cwhen the thermal pressure is not updated for offline CPUs. It's similar fix that has been merged recently forcpufreq_cooling.c:2ad8ccc17d1e4270cf65a3f2
Quoted 7 lines
Changes:
v2:
- added Reviewed-by from Thara for patch 3/5
- changed the doxygen comment and usedmult_frac()according to Thara's suggestion in patch 1/5
v1 -> [1]
Gentle ping.
Viresh, Daniel, Rafael could you have a look at this, please?
Regards,
Lukasz