PATCH 1/1 MD: Allow restarting an interrupted incremental recovery.

If an incremental recovery was interrupted, a subsequent re-add will result in a full recovery, even though an incremental should be possible (seen with raid1).

Solve this problem by not updating the superblock on the recovering device until array is not degraded any longer.

---
 drivers/md/md.c |   10 +++++++---
 1 files changed, 7 insertions(+), 3 deletions(-)
drivers/md/md.c +7 -3
index 5404b22..8ebbae4 100644
@@ -2444,9 +2444,12 @@ repeat:
 			continue; /* no noise on spare devices */
 		if (test_bit(Faulty, &rdev->flags))
 			dprintk("(skipping faulty ");
+		else if (rdev->saved_raid_disk != -1)
+			dprintk("(skipping incremental s/r ");
 
 		dprintk("%s ", bdevname(rdev->bdev,b));
-		if (!test_bit(Faulty, &rdev->flags)) {
+		if (!test_bit(Faulty, &rdev->flags) &&
+		    rdev->saved_raid_disk == -1) {
 			md_super_write(mddev,rdev,
 				       rdev->sb_start, rdev->sb_size,
 				       rdev->sb_page);
@@ -7353,15 +7356,16 @@ static void reap_sync_thread(mddev_t *mddev)
 	if (test_bit(MD_RECOVERY_RESHAPE, &mddev->recovery) &&
 	    mddev->pers->finish_reshape)
 		mddev->pers->finish_reshape(mddev);
-	md_update_sb(mddev, 1);
 
 	/* if array is no-longer degraded, then any saved_raid_disk
-	 * information must be scrapped
+	 * information must be scrapped, and superblock for
+	 * incrementally recovered device written out.
 	 */
 	if (!mddev->degraded)
 		list_for_each_entry(rdev, &mddev->disks, same_set)
 			rdev->saved_raid_disk = -1;
 
+	md_update_sb(mddev, 1);
 	clear_bit(MD_RECOVERY_RUNNING, &mddev->recovery);
 	clear_bit(MD_RECOVERY_SYNC, &mddev->recovery);
 	clear_bit(MD_RECOVERY_RESHAPE, &mddev->recovery);
Signature · 1 line
1.7.4.1
#1 lore raw
Quoted 40 lines · On Mon, 17 Oct 2011 19:22:11 -0400 Andrei Warkentin <[email protected]> wrote:

If an incremental recovery was interrupted, a subsequent re-add will result in a full recovery, even though an incremental should be possible (seen with raid1).

Solve this problem by not updating the superblock on the recovering device until array is not degraded any longer.

---
 drivers/md/md.c |   10 +++++++---
 1 files changed, 7 insertions(+), 3 deletions(-)
drivers/md/md.c +5 -3
index 5404b22..8ebbae4 100644
@@ -2444,9 +2444,12 @@ repeat:
 			continue; /* no noise on spare devices */
 		if (test_bit(Faulty, &rdev->flags))
 			dprintk("(skipping faulty ");
+		else if (rdev->saved_raid_disk != -1)
+			dprintk("(skipping incremental s/r ");
 
 		dprintk("%s ", bdevname(rdev->bdev,b));
-		if (!test_bit(Faulty, &rdev->flags)) {
+		if (!test_bit(Faulty, &rdev->flags) &&
+		    rdev->saved_raid_disk == -1) {
 			md_super_write(mddev,rdev,
 				       rdev->sb_start, rdev->sb_size,
 				       rdev->sb_page);
@@ -7353,15 +7356,16 @@ static void reap_sync_thread(mddev_t *mddev)
 	if (test_bit(MD_RECOVERY_RESHAPE, &mddev->recovery) &&
 	    mddev->pers->finish_reshape)
 		mddev->pers->finish_reshape(mddev);
-	md_update_sb(mddev, 1);
 
 	/* if array is no-longer degraded, then any saved_raid_disk
-	 * information must be scrapped
+	 * information must be scrapped, and superblock for

drivers/md/md.c static void reap_sync_thread(mddev_t *mddev) · line 7371

Quoted 10 lines
drivers/md/md.c +2 -0
+	 * incrementally recovered device written out.
 	 */
 	if (!mddev->degraded)
 		list_for_each_entry(rdev, &mddev->disks, same_set)
 			rdev->saved_raid_disk = -1;
 
+	md_update_sb(mddev, 1);
 	clear_bit(MD_RECOVERY_RUNNING, &mddev->recovery);
 	clear_bit(MD_RECOVERY_SYNC, &mddev->recovery);
 	clear_bit(MD_RECOVERY_RESHAPE, &mddev->recovery);

Thanks. I've applied this and pushed it to my for-next branch.

My current HEAD use pr_debug instead of dprintk so I fixed that.

Also I realised that clearing saved_raid_disk when an array is not degraded is no longer enough. We also need to clear it when the device becomes In_sync.
Consider a 3-drive RAID1 with two drives missing. You add back one of them and when it is recovered it needs saved_raid_disk cleared so that the superblock gets written out.

So below is what I applied.

Thanks,
NeilBrown

commit d70ed2e4fafdbef0800e73942482bb075c21578b

Author: Andrei Warkentin <[email protected]>
Date:   Tue Oct 18 12:16:48 2011 +1100

MD: Allow restarting an interrupted incremental recovery.

If an incremental recovery was interrupted, a subsequent re-add will result in a full recovery, even though an incremental should be possible (seen with raid1).

Solve this problem by not updating the superblock on the recovering device until array is not degraded any longer.

drivers/md/md.c +15 -7
index 0ea3485..e8d198d 100644
@@ -2449,7 +2449,8 @@ repeat:
 		if (rdev->sb_loaded != 1)
 			continue; /* no noise on spare devices */
 
-		if (!test_bit(Faulty, &rdev->flags)) {
+		if (!test_bit(Faulty, &rdev->flags) &&
+		    rdev->saved_raid_disk == -1) {
 			md_super_write(mddev,rdev,
 				       rdev->sb_start, rdev->sb_size,
 				       rdev->sb_page);
@@ -2465,9 +2466,12 @@ repeat:
 				rdev->badblocks.size = 0;
 			}
 
-		} else
+		} else if (test_bit(Faulty, &rdev->flags))
 			pr_debug("md: %s (skipping faulty)\n",
 				 bdevname(rdev->bdev, b));
+		else
+			pr_debug("(skipping incremental s/r ");
+
 		if (mddev->level == LEVEL_MULTIPATH)
 			/* only need to write one superblock... */
 			break;
@@ -7366,15 +7370,19 @@ static void reap_sync_thread(struct mddev *mddev)
 	if (test_bit(MD_RECOVERY_RESHAPE, &mddev->recovery) &&
 	    mddev->pers->finish_reshape)
 		mddev->pers->finish_reshape(mddev);
-	md_update_sb(mddev, 1);
 
-	/* if array is no-longer degraded, then any saved_raid_disk
-	 * information must be scrapped
+	/* If array is no-longer degraded, then any saved_raid_disk
+	 * information must be scrapped.  Also if any device is now
+	 * In_sync we must scrape the saved_raid_disk for that device
+	 * do the superblock for an incrementally recovered device
+	 * written out.
 	 */
-	if (!mddev->degraded)
-		list_for_each_entry(rdev, &mddev->disks, same_set)
+	list_for_each_entry(rdev, &mddev->disks, same_set)
+		if (!mddev->degraded ||
+		    test_bit(In_sync, &rdev->flags))
 			rdev->saved_raid_disk = -1;
 
+	md_update_sb(mddev, 1);
 	clear_bit(MD_RECOVERY_RUNNING, &mddev->recovery);
 	clear_bit(MD_RECOVERY_SYNC, &mddev->recovery);
 	clear_bit(MD_RECOVERY_RESHAPE, &mddev->recovery);
#2 lore raw

Hi Neil,

----- Original Message -----

Quoted 35 lines

From: "NeilBrown" <[email protected]>
To: "Andrei Warkentin" <[email protected]>
Cc: [email protected]
Sent: Monday, October 17, 2011 9:22:39 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.

Quoted 10 lines · On Mon, 17 Oct 2011 19:22:11 -0400 Andrei Warkentin <[email protected]> wrote:

If an incremental recovery was interrupted, a subsequent re-add will result in a full recovery, even though an incremental should be possible (seen with raid1).

Solve this problem by not updating the superblock on the recovering device until array is not degraded any longer.

---

Thanks. I've applied this and pushed it to my for-next branch.

My current HEAD use pr_debug instead of dprintk so I fixed that.

Also I realised that clearing saved_raid_disk when an array is not degraded
is no longer enough. We also need to clear it when the device becomes
In_sync.
Consider a 3-drive RAID1 with two drives missing. You add back one of them
and when it is recovered it needs saved_raid_disk cleared so that the superblock gets written out.

Quoted 2 lines

So below is what I applied.

Wouldn't all drives being In_sync imply the array is not degraded - i.e. can the check for a degraded array be omitted then, at all? I.e. if after the resync the In_sync bit is set - drop saved_raid_role.

A

#3 lore raw

Hi Neil,

----- Original Message -----

Quoted 17 lines

From: "Andrei Warkentin" <[email protected]>
To: "NeilBrown" <[email protected]>
Cc: [email protected], "Andrei Warkentin" <[email protected]>
Sent: Tuesday, October 18, 2011 1:07:24 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.

Quoted 11 lines

Also I realised that clearing saved_raid_disk when an array is not degraded
is no longer enough. We also need to clear it when the device becomes
In_sync.
Consider a 3-drive RAID1 with two drives missing. You add back one of them
and when it is recovered it needs saved_raid_disk cleared so that the
superblock gets written out.

Quoted 9 lines
Quoted 2 lines

So below is what I applied.

Wouldn't all drives being In_sync imply the array is not degraded - i.e. can the
check for a degraded array be omitted then, at all? I.e. if after the resync the
In_sync bit is set - drop saved_raid_role.

Come to think of it - checking for !mddev->degraded might not be a good idea at all. After all, you could imagine a situation where in a RAID1 array with A and B, A is recovered from B and then B goes away before the SBs are flushed due to resync finishing - you would still want A's SB to be flushed, even if array is degraded.

Otherwise you'll end up with another incremental rebuilding A, and lost/inconsistent data after array became degraded (since it was going to A, but we never wrote out its SB, since array is degraded).

What do you think?

A

#4 lore raw

----- Original Message -----

Quoted 48 lines

From: "Andrei Warkentin" <[email protected]>
To: "NeilBrown" <[email protected]>
Cc: [email protected], "Andrei Warkentin" <[email protected]>
Sent: Tuesday, October 18, 2011 4:06:05 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.

Hi Neil,

----- Original Message -----

Quoted 24 lines

From: "Andrei Warkentin" <[email protected]>
To: "NeilBrown" <[email protected]>
Cc: [email protected], "Andrei Warkentin" <[email protected]>
Sent: Tuesday, October 18, 2011 1:07:24 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.

Quoted 13 lines

Also I realised that clearing saved_raid_disk when an array is not
degraded
is no longer enough. We also need to clear it when the device becomes
In_sync.
Consider a 3-drive RAID1 with two drives missing. You add back one
of them
and when it is recovered it needs saved_raid_disk cleared so that the
superblock gets written out.

Quoted 2 lines

So below is what I applied.

Quoted 7 lines

Wouldn't all drives being In_sync imply the array is not degraded - i.e. can the
check for a degraded array be omitted then, at all? I.e. if after the
resync the
In_sync bit is set - drop saved_raid_role.

Come to think of it - checking for !mddev->degraded might not be a good idea at all. After all, you
could imagine a situation where in a RAID1 array with A and B, A is recovered from B and then B goes away before
the SBs are flushed due to resync finishing - you would still want A's SB to be flushed, even if array is degraded.

Quoted 4 lines

Otherwise you'll end up with another incremental rebuilding A, and lost/inconsistent data after array became degraded (since it was going to A, but we never wrote out its SB, since array is degraded).

Errr, I confused myself. This is exactly why you added the check for In_sync. OTOH, isn't the mddev->degraded now superflous - i.e. if all disks are In_sync, there is no need to check for degraded, right?

A

#5 lore raw
Quoted 54 lines · On Tue, 18 Oct 2011 13:15:27 -0700 (PDT) Andrei Warkentin…

----- Original Message -----

Quoted 48 lines

From: "Andrei Warkentin" <[email protected]>
To: "NeilBrown" <[email protected]>
Cc: [email protected], "Andrei Warkentin" <[email protected]>
Sent: Tuesday, October 18, 2011 4:06:05 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.

Hi Neil,

----- Original Message -----

Quoted 24 lines

From: "Andrei Warkentin" <[email protected]>
To: "NeilBrown" <[email protected]>
Cc: [email protected], "Andrei Warkentin" <[email protected]>
Sent: Tuesday, October 18, 2011 1:07:24 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.

Quoted 13 lines

Also I realised that clearing saved_raid_disk when an array is not
degraded
is no longer enough. We also need to clear it when the device becomes
In_sync.
Consider a 3-drive RAID1 with two drives missing. You add back one
of them
and when it is recovered it needs saved_raid_disk cleared so that the
superblock gets written out.

Quoted 2 lines

So below is what I applied.

Quoted 7 lines

Wouldn't all drives being In_sync imply the array is not degraded - i.e. can the
check for a degraded array be omitted then, at all? I.e. if after the
resync the
In_sync bit is set - drop saved_raid_role.

Come to think of it - checking for !mddev->degraded might not be a good idea at all. After all, you
could imagine a situation where in a RAID1 array with A and B, A is recovered from B and then B goes away before
the SBs are flushed due to resync finishing - you would still want A's SB to be flushed, even if array is degraded.

Quoted 4 lines

Otherwise you'll end up with another incremental rebuilding A, and lost/inconsistent data after array became degraded (since it was going to A, but we never wrote out its SB, since array is degraded).

Quoted 5 lines

Errr, I confused myself. This is exactly why you added the check for In_sync. OTOH, isn't the mddev->degraded now superflous - i.e. if all disks are In_sync, there is no need to check for degraded, right?

A

Maybe.
However once we clear mddev->degraded we can start clearing bits in the bitmap, so any saved_raid_disk information is definitely invalid and should be removed.
You would expect that there won't be any, and you would probably be right. But it feels safer keeping the check there. It is probably superfluous, but sometimes a little paranoia can be a good thing.

Thanks,
NeilBrown

#6 lore raw

----- Original Message -----

Quoted 84 lines

From: "NeilBrown" <[email protected]>
To: "Andrei Warkentin" <[email protected]>
Cc: [email protected], "Andrei Warkentin" <[email protected]>
Sent: Tuesday, October 18, 2011 7:00:08 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.

Quoted 67 lines · On Tue, 18 Oct 2011 13:15:27 -0700 (PDT) Andrei Warkentin…

----- Original Message -----

Quoted 59 lines

From: "Andrei Warkentin" <[email protected]>
To: "NeilBrown" <[email protected]>
Cc: [email protected], "Andrei Warkentin" <[email protected]>
Sent: Tuesday, October 18, 2011 4:06:05 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.

Hi Neil,

----- Original Message -----

Quoted 28 lines

From: "Andrei Warkentin" <[email protected]>
To: "NeilBrown" <[email protected]>
Cc: [email protected], "Andrei Warkentin" <[email protected]>
Sent: Tuesday, October 18, 2011 1:07:24 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.

Quoted 17 lines

Also I realised that clearing saved_raid_disk when an array is
not
degraded
is no longer enough. We also need to clear it when the device
becomes
In_sync.
Consider a 3-drive RAID1 with two drives missing. You add back
one
of them
and when it is recovered it needs saved_raid_disk cleared so that
the
superblock gets written out.

Quoted 2 lines

So below is what I applied.

Quoted 9 lines

Wouldn't all drives being In_sync imply the array is not degraded -
i.e. can the
check for a degraded array be omitted then, at all? I.e. if after
the
resync the
In_sync bit is set - drop saved_raid_role.

Come to think of it - checking for !mddev->degraded might not be a
good idea at all. After all, you
could imagine a situation where in a RAID1 array with A and B, A is
recovered from B and then B goes away before
the SBs are flushed due to resync finishing - you would still want
A's SB to be flushed, even if array is degraded.

Quoted 6 lines

Otherwise you'll end up with another incremental rebuilding A, and
lost/inconsistent data after array became degraded (since it was going to A, but we never wrote out its SB, since array is degraded).

Quoted 7 lines

Errr, I confused myself. This is exactly why you added the check for In_sync.
OTOH, isn't the mddev->degraded now superflous - i.e. if all disks are In_sync,
there is no need to check for degraded, right?

A

Quoted 12 lines

Maybe.
However once we clear mddev->degraded we can start clearing bits in the
bitmap, so any saved_raid_disk information is definitely invalid and should
be removed.
You would expect that there won't be any, and you would probably be right.
But it feels safer keeping the check there. It is probably superfluous, but
sometimes a little paranoia can be a good thing.

Sounds fair, given that mddev->degraded is controlled by the personality...

Many thanks for your help,
A