MD: Allow restarting an interrupted incremental recovery.
PATCH 1/1 MD: Allow restarting an interrupted incremental recovery.
If an incremental recovery was interrupted, a subsequent re-add will result in a full recovery, even though an incremental should be possible (seen with raid1).
Solve this problem by not updating the superblock on the recovering device until array is not degraded any longer.
--- drivers/md/md.c | 10 +++++++--- 1 files changed, 7 insertions(+), 3 deletions(-)
drivers/md/md.c +7 -3
@@ -2444,9 +2444,12 @@ repeat:continue ;/* no noise on spare devices */ if (test_bit (Faulty, &rdev->flags))dprintk ("(skipping faulty " ); +else if (rdev->saved_raid_disk !=-1 ) +dprintk ("(skipping incremental s/r " );dprintk ("%s " ,bdevname (rdev->bdev,b)); -if (!test_bit (Faulty, &rdev->flags)) { +if (!test_bit (Faulty, &rdev->flags) && + rdev->saved_raid_disk ==-1 ) {md_super_write (mddev,rdev, rdev->sb_start, rdev->sb_size, rdev->sb_page);
@@ -7353,15 +7356,16 @@ static void reap_sync_thread(mddev_t *mddev)if (test_bit (MD_RECOVERY_RESHAPE , &mddev->recovery) && mddev->pers->finish_reshape) mddev->pers->finish_reshape (mddev); -md_update_sb (mddev,1 );/* if array is no-longer degraded, then any saved_raid_disk -* information must be scrapped +* information must be scrapped, and superblock for +* incrementally recovered device written out. */ if (!mddev->degraded)list_for_each_entry (rdev, &mddev->disks, same_set) rdev->saved_raid_disk =-1 ; +md_update_sb (mddev,1 );clear_bit (MD_RECOVERY_RUNNING , &mddev->recovery);clear_bit (MD_RECOVERY_SYNC , &mddev->recovery);clear_bit (MD_RECOVERY_RESHAPE , &mddev->recovery);
Signature · 1 line
1.7.4.1
Quoted 40 lines · On Mon, 17 Oct 2011 19:22:11 -0400 Andrei Warkentin <[email protected]> wrote:
If an incremental recovery was interrupted, a subsequent re-add will result in a full recovery, even though an incremental should be possible (seen with raid1).
Solve this problem by not updating the superblock on the recovering device until array is not degraded any longer.
Cc Neil Brown <[email protected]>Signed-off-by Andrei Warkentin <[email protected]>--- drivers/md/md.c | 10 +++++++--- 1 files changed, 7 insertions(+), 3 deletions(-)drivers/md/md.c +5
-3@@ -2444,9 +2444,12 @@ repeat:continue ;/* no noise on spare devices */ if (test_bit (Faulty, &rdev->flags))dprintk ("(skipping faulty " ); +else if (rdev->saved_raid_disk !=-1 ) +dprintk ("(skipping incremental s/r " );dprintk ("%s " ,bdevname (rdev->bdev,b)); -if (!test_bit (Faulty, &rdev->flags)) { +if (!test_bit (Faulty, &rdev->flags) && + rdev->saved_raid_disk ==-1 ) {md_super_write (mddev,rdev, rdev->sb_start, rdev->sb_size, rdev->sb_page);@@ -7353,15 +7356,16 @@ static void reap_sync_thread(mddev_t *mddev)if (test_bit (MD_RECOVERY_RESHAPE , &mddev->recovery) && mddev->pers->finish_reshape) mddev->pers->finish_reshape (mddev); -md_update_sb (mddev,1 );/* if array is no-longer degraded, then any saved_raid_disk -* information must be scrapped +* information must be scrapped, and superblock for
drivers/md/md.c static void reap_sync_thread(mddev_t *mddev) · line 7371
Quoted 10 lines
drivers/md/md.c +2
-0+* incrementally recovered device written out. */ if (!mddev->degraded)list_for_each_entry (rdev, &mddev->disks, same_set) rdev->saved_raid_disk =-1 ; +md_update_sb (mddev,1 );clear_bit (MD_RECOVERY_RUNNING , &mddev->recovery);clear_bit (MD_RECOVERY_SYNC , &mddev->recovery);clear_bit (MD_RECOVERY_RESHAPE , &mddev->recovery);
Thanks. I've applied this and pushed it to my for-next branch.
My current HEAD use pr_debug instead of dprintk so I fixed that.
Also I realised that clearing saved_raid_disk when an array is not degraded is no longer enough. We also need to clear it when the device becomes In_sync.
Consider a 3-drive RAID1 with two drives missing. You add back one of them and when it is recovered it needs saved_raid_disk cleared so that the superblock gets written out.
So below is what I applied.
Thanks,
NeilBrown
commit d70ed2e4fafdbef0800e73942482bb075c21578b
Author: Andrei Warkentin <[email protected]> Date: Tue Oct 18 12:16:48 2011 +1100
MD: Allow restarting an interrupted incremental recovery.
If an incremental recovery was interrupted, a subsequent re-add will result in a full recovery, even though an incremental should be possible (seen with raid1).
Solve this problem by not updating the superblock on the recovering device until array is not degraded any longer.
drivers/md/md.c +15 -7
@@ -2449,7 +2449,8 @@ repeat:if (rdev->sb_loaded !=1 )continue ;/* no noise on spare devices */ -if (!test_bit (Faulty, &rdev->flags)) { +if (!test_bit (Faulty, &rdev->flags) && + rdev->saved_raid_disk ==-1 ) {md_super_write (mddev,rdev, rdev->sb_start, rdev->sb_size, rdev->sb_page);
@@ -2465,9 +2466,12 @@ repeat: rdev->badblocks.size =0 ; } - }else + }else if (test_bit (Faulty, &rdev->flags))pr_debug ("md: %s (skipping faulty)\n" ,bdevname (rdev->bdev, b)); +else +pr_debug ("(skipping incremental s/r " ); +if (mddev->level ==LEVEL_MULTIPATH )/* only need to write one superblock... */ break ;
@@ -7366,15 +7370,19 @@ static void reap_sync_thread(struct mddev *mddev)if (test_bit (MD_RECOVERY_RESHAPE , &mddev->recovery) && mddev->pers->finish_reshape) mddev->pers->finish_reshape (mddev); -md_update_sb (mddev,1 ); -/* if array is no-longer degraded, then any saved_raid_disk -* information must be scrapped +/* If array is no-longer degraded, then any saved_raid_disk +* information must be scrapped. Also if any device is now +* In_sync we must scrape the saved_raid_disk for that device +* do the superblock for an incrementally recovered device +* written out. */ -if (!mddev->degraded) -list_for_each_entry (rdev, &mddev->disks, same_set) +list_for_each_entry (rdev, &mddev->disks, same_set) +if (!mddev->degraded || +test_bit (In_sync, &rdev->flags)) rdev->saved_raid_disk =-1 ; +md_update_sb (mddev,1 );clear_bit (MD_RECOVERY_RUNNING , &mddev->recovery);clear_bit (MD_RECOVERY_SYNC , &mddev->recovery);clear_bit (MD_RECOVERY_RESHAPE , &mddev->recovery);
Hi Neil,
----- Original Message -----
Quoted 35 lines
From: "NeilBrown" <[email protected]>
To: "Andrei Warkentin" <[email protected]>
Cc: [email protected]
Sent: Monday, October 17, 2011 9:22:39 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.Quoted 10 lines · On Mon, 17 Oct 2011 19:22:11 -0400 Andrei Warkentin <[email protected]> wrote:
If an incremental recovery was interrupted, a subsequent re-add will result in a full recovery, even though an incremental should be possible (seen with raid1).
Solve this problem by not updating the superblock on the recovering device until array is not degraded any longer.
Cc Neil Brown <[email protected]>Signed-off-by Andrei Warkentin <[email protected]>---
Thanks. I've applied this and pushed it to my for-next branch.
My current HEAD use
pr_debuginstead of dprintk so I fixed that.Also I realised that clearing
saved_raid_diskwhen an array is not degraded
is no longer enough. We also need to clear it when the device becomesIn_sync.
Consider a 3-drive RAID1 with two drives missing. You add back one of them
and when it is recovered it needssaved_raid_diskcleared so that the superblock gets written out.
Quoted 2 lines
So below is what I applied.
Wouldn't all drives being In_sync imply the array is not degraded - i.e. can the check for a degraded array be omitted then, at all? I.e. if after the resync the In_sync bit is set - drop saved_raid_role.
A
Hi Neil,
----- Original Message -----
Quoted 17 lines
From: "Andrei Warkentin" <[email protected]>
To: "NeilBrown" <[email protected]>
Cc: [email protected], "Andrei Warkentin" <[email protected]>
Sent: Tuesday, October 18, 2011 1:07:24 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.Quoted 11 lines
Also I realised that clearing
saved_raid_diskwhen an array is not degraded
is no longer enough. We also need to clear it when the device becomesIn_sync.
Consider a 3-drive RAID1 with two drives missing. You add back one of them
and when it is recovered it needssaved_raid_diskcleared so that the
superblock gets written out.
Quoted 9 lines
Quoted 2 lines
So below is what I applied.
Wouldn't all drives being
In_syncimply the array is not degraded - i.e. can the
check for a degraded array be omitted then, at all? I.e. if after the resync theIn_syncbit is set - dropsaved_raid_role.
Come to think of it - checking for !mddev->degraded might not be a good idea at all. After all, you could imagine a situation where in a RAID1 array with A and B, A is recovered from B and then B goes away before the SBs are flushed due to resync finishing - you would still want A's SB to be flushed, even if array is degraded.
Otherwise you'll end up with another incremental rebuilding A, and lost/inconsistent data after array became degraded (since it was going to A, but we never wrote out its SB, since array is degraded).
What do you think?
A
----- Original Message -----
Quoted 48 lines
From: "Andrei Warkentin" <[email protected]>
To: "NeilBrown" <[email protected]>
Cc: [email protected], "Andrei Warkentin" <[email protected]>
Sent: Tuesday, October 18, 2011 4:06:05 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.Hi Neil,
----- Original Message -----
Quoted 24 lines
From: "Andrei Warkentin" <[email protected]>
To: "NeilBrown" <[email protected]>
Cc: [email protected], "Andrei Warkentin" <[email protected]>
Sent: Tuesday, October 18, 2011 1:07:24 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.Quoted 13 lines
Also I realised that clearing
saved_raid_diskwhen an array is not
degraded
is no longer enough. We also need to clear it when the device becomesIn_sync.
Consider a 3-drive RAID1 with two drives missing. You add back one
of them
and when it is recovered it needssaved_raid_diskcleared so that the
superblock gets written out.Quoted 2 lines
So below is what I applied.
Quoted 7 lines
Wouldn't all drives being
In_syncimply the array is not degraded - i.e. can the
check for a degraded array be omitted then, at all? I.e. if after the
resync theIn_syncbit is set - dropsaved_raid_role.Come to think of it - checking for !mddev->degraded might not be a good idea at all. After all, you
could imagine a situation where in a RAID1 array with A and B, A is recovered from B and then B goes away before
the SBs are flushed due to resync finishing - you would still want A's SB to be flushed, even if array is degraded.
Quoted 4 lines
Otherwise you'll end up with another incremental rebuilding A, and lost/inconsistent data after array became degraded (since it was going to A, but we never wrote out its SB, since array is degraded).
Errr, I confused myself. This is exactly why you added the check for In_sync. OTOH, isn't the mddev->degraded now superflous - i.e. if all disks are In_sync, there is no need to check for degraded, right?
A
Quoted 54 lines · On Tue, 18 Oct 2011 13:15:27 -0700 (PDT) Andrei Warkentin…
----- Original Message -----
Quoted 48 lines
From: "Andrei Warkentin" <[email protected]>
To: "NeilBrown" <[email protected]>
Cc: [email protected], "Andrei Warkentin" <[email protected]>
Sent: Tuesday, October 18, 2011 4:06:05 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.Hi Neil,
----- Original Message -----
Quoted 24 lines
From: "Andrei Warkentin" <[email protected]>
To: "NeilBrown" <[email protected]>
Cc: [email protected], "Andrei Warkentin" <[email protected]>
Sent: Tuesday, October 18, 2011 1:07:24 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.Quoted 13 lines
Also I realised that clearing
saved_raid_diskwhen an array is not
degraded
is no longer enough. We also need to clear it when the device becomesIn_sync.
Consider a 3-drive RAID1 with two drives missing. You add back one
of them
and when it is recovered it needssaved_raid_diskcleared so that the
superblock gets written out.Quoted 2 lines
So below is what I applied.
Quoted 7 lines
Wouldn't all drives being
In_syncimply the array is not degraded - i.e. can the
check for a degraded array be omitted then, at all? I.e. if after the
resync theIn_syncbit is set - dropsaved_raid_role.Come to think of it - checking for !mddev->degraded might not be a good idea at all. After all, you
could imagine a situation where in a RAID1 array with A and B, A is recovered from B and then B goes away before
the SBs are flushed due to resync finishing - you would still want A's SB to be flushed, even if array is degraded.Quoted 4 lines
Otherwise you'll end up with another incremental rebuilding A, and lost/inconsistent data after array became degraded (since it was going to A, but we never wrote out its SB, since array is degraded).
Quoted 5 lines
Errr, I confused myself. This is exactly why you added the check for
In_sync. OTOH, isn't themddev->degradednow superflous - i.e. if all disks areIn_sync, there is no need to check for degraded, right?A
Maybe.
However once we clear mddev->degraded we can start clearing bits in the bitmap, so any saved_raid_disk information is definitely invalid and should be removed.
You would expect that there won't be any, and you would probably be right. But it feels safer keeping the check there. It is probably superfluous, but sometimes a little paranoia can be a good thing.
Thanks,
NeilBrown
----- Original Message -----
Quoted 84 lines
From: "NeilBrown" <[email protected]>
To: "Andrei Warkentin" <[email protected]>
Cc: [email protected], "Andrei Warkentin" <[email protected]>
Sent: Tuesday, October 18, 2011 7:00:08 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.Quoted 67 lines · On Tue, 18 Oct 2011 13:15:27 -0700 (PDT) Andrei Warkentin…
----- Original Message -----
Quoted 59 lines
From: "Andrei Warkentin" <[email protected]>
To: "NeilBrown" <[email protected]>
Cc: [email protected], "Andrei Warkentin" <[email protected]>
Sent: Tuesday, October 18, 2011 4:06:05 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.Hi Neil,
----- Original Message -----
Quoted 28 lines
From: "Andrei Warkentin" <[email protected]>
To: "NeilBrown" <[email protected]>
Cc: [email protected], "Andrei Warkentin" <[email protected]>
Sent: Tuesday, October 18, 2011 1:07:24 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.Quoted 17 lines
Also I realised that clearing
saved_raid_diskwhen an array is
not
degraded
is no longer enough. We also need to clear it when the device
becomesIn_sync.
Consider a 3-drive RAID1 with two drives missing. You add back
one
of them
and when it is recovered it needssaved_raid_diskcleared so that
the
superblock gets written out.Quoted 2 lines
So below is what I applied.
Quoted 9 lines
Wouldn't all drives being
In_syncimply the array is not degraded -
i.e. can the
check for a degraded array be omitted then, at all? I.e. if after
the
resync theIn_syncbit is set - dropsaved_raid_role.Come to think of it - checking for !mddev->degraded might not be a
good idea at all. After all, you
could imagine a situation where in a RAID1 array with A and B, A is
recovered from B and then B goes away before
the SBs are flushed due to resync finishing - you would still want
A's SB to be flushed, even if array is degraded.Quoted 6 lines
Otherwise you'll end up with another incremental rebuilding A, and
lost/inconsistent data after array became degraded (since it was going to A, but we never wrote out its SB, since array is degraded).Quoted 7 lines
Errr, I confused myself. This is exactly why you added the check for
In_sync.
OTOH, isn't themddev->degradednow superflous - i.e. if all disks areIn_sync,
there is no need to check for degraded, right?A
Quoted 12 lines
Maybe.
However once we clearmddev->degradedwe can start clearing bits in the
bitmap, so anysaved_raid_diskinformation is definitely invalid and should
be removed.
You would expect that there won't be any, and you would probably be right.
But it feels safer keeping the check there. It is probably superfluous, but
sometimes a little paranoia can be a good thing.
Sounds fair, given that mddev->degraded is controlled by the personality...
Many thanks for your help,
A