Skip to contentSkip to conversation

Add default values for IBM XIV Storage System.

PATCH In review Oren Held 4 participants 4 messages Dec 28, 2011 – Jan 12, 2012 Device mapper

lore
Share & tools
lore

Oren Held

author
#0 lore raw

PATCH 1/1 Add default values for IBM XIV Storage System.

---
 libmultipath/hwtable.c |   18 ++++++++++++++++++
 1 files changed, 18 insertions(+), 0 deletions(-)
libmultipath/hwtable.c +18 -0
index 7697883..8dceaba 100644
@@ -771,6 +771,24 @@ static struct hwentry default_hw[] = {
 		.prio_name     = PRIO_ALUA,
 		.prio_args     = NULL,
 	},
+        {
+                /* IBM XIV Storage System */
+                .vendor        = "IBM",
+                .product       = "2810XIV",
+                .getuid        = DEFAULT_GETUID,
+                .features      = "1 queue_if_no_path",
+                .hwhandler     = DEFAULT_HWHANDLER,
+                .selector      = DEFAULT_SELECTOR,
+                .pgpolicy      = MULTIBUS,
+                .pgfailback    = 15,
+                .rr_weight     = RR_WEIGHT_NONE,
+                .no_path_retry = NO_PATH_RETRY_UNDEF,
+                .minio         = 15,
+                .minio_rq      = DEFAULT_MINIO_RQ,
+                .checker_name  = TUR,
+                .prio_name     = DEFAULT_PRIO,
+                .prio_args     = NULL,
+        },
 	/*
 	 * IBM Power Virtual SCSI Devices
 	 *
#1 lore raw
Quoted 1 line · Oren Held

Add default values for IBM XIV Storage System.

Applied and pushed.

Thanks.

Signature · 3 lines
Christophe Varoqui
OpenSVC - Tools to scale
http://www.opensvc.com/
#3 lore raw

2812 is an internal IBM model number, which means 'longer warranty' (so it doesn't actually replace 2810).
(http://rogerluethy.wordpress.com/2011/07/12/ibm-xiv-storage-system-gen3-offers-a-new-high-performance-model-114-for-machine-types-2810-and-2812/)

What matters is that this internal IBM model number is *not* exposed by SCSI inquiry.
To this day, all IBM XIV models report 'IBM'/'2810XIV' in the vendor/product fields of SCSI inquiry, regardless of being internally known as 2810, 2812 or 2814. It's deliberate, and there's no plan to change this, AFAIK.

Thanks

Oren H
XIV Host Software team

Quoted 30 lines · August Sodora

The new XIV machine code is actually 2812, not sure if this matters.

August Sodora
[email protected]
(201) 280-8138

Quoted 11 lines · Christophe Varoqui
Quoted 1 line · Oren Held

Add default values for IBM XIV Storage System.

Applied and pushed.

Thanks.
--
Christophe Varoqui
OpenSVC - Tools to scale
http://www.opensvc.com/

Quoted 4 lines

--
dm-devel mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/dm-devel

--
dm-devel mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/dm-devel