Add default values for IBM XIV Storage System.
PATCH 1/1 Add default values for IBM XIV Storage System.
--- libmultipath/hwtable.c | 18 ++++++++++++++++++ 1 files changed, 18 insertions(+), 0 deletions(-)
libmultipath/hwtable.c +18 -0
@@ -771,6 +771,24 @@ static struct hwentry default_hw[] = { .prio_name = PRIO_ALUA, .prio_args = NULL, }, + { +/* IBM XIV Storage System */ + .vendor = "IBM", + .product = "2810XIV", + .getuid = DEFAULT_GETUID, + .features = "1 queue_if_no_path", + .hwhandler = DEFAULT_HWHANDLER, + .selector = DEFAULT_SELECTOR, + .pgpolicy = MULTIBUS, + .pgfailback = 15, + .rr_weight = RR_WEIGHT_NONE, + .no_path_retry = NO_PATH_RETRY_UNDEF, + .minio = 15, + .minio_rq = DEFAULT_MINIO_RQ, + .checker_name = TUR, + .prio_name = DEFAULT_PRIO, + .prio_args = NULL, + },/* * IBM Power Virtual SCSI Devices *
Quoted 1 line · Oren Held
Add default values for IBM XIV Storage System.
Applied and pushed.
Thanks.
Signature · 3 lines
Christophe Varoqui OpenSVC - Tools to scale http://www.opensvc.com/
The new XIV machine code is actually 2812, not sure if this matters.
August Sodora
[email protected]
(201) 280-8138
Quoted 15 lines · Christophe Varoqui
Quoted 1 line · Oren Held
Add default values for IBM XIV Storage System.
Applied and pushed.
Thanks.
--
Christophe Varoqui
OpenSVC - Tools to scale
http://www.opensvc.com/--
dm-devel mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/dm-devel
2812 is an internal IBM model number, which means 'longer warranty' (so it doesn't actually replace 2810).
(http://rogerluethy.wordpress.com/2011/07/12/ibm-xiv-storage-system-gen3-offers-a-new-high-performance-model-114-for-machine-types-2810-and-2812/)
What matters is that this internal IBM model number is *not* exposed by SCSI inquiry.
To this day, all IBM XIV models report 'IBM'/'2810XIV' in the vendor/product fields of SCSI inquiry, regardless of being internally known as 2810, 2812 or 2814. It's deliberate, and there's no plan to change this, AFAIK.
Thanks
Oren H
XIV Host Software team
Quoted 30 lines · August Sodora
The new XIV machine code is actually 2812, not sure if this matters.
August Sodora
[email protected]
(201) 280-8138Quoted 11 lines · Christophe Varoqui
Quoted 1 line · Oren Held
Add default values for IBM XIV Storage System.
Applied and pushed.
Thanks.
--
Christophe Varoqui
OpenSVC - Tools to scale
http://www.opensvc.com/Quoted 4 lines
--
dm-devel mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/dm-devel--
dm-devel mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/dm-devel