Skip to contentSkip to conversation

Multipath and SAN Fabric failover

DISCUSSION John Little 2 participants 2 messages Sep 14, 2006 Device mapper

lore
Share & tools
lore
#0 lore raw

[email protected] wrote on 09/10/2006 03:23:55 PM:

Quoted 17 lines

Heya,

Quoted 3 lines

Just to make sure that I've covered everything I partitioned the disk as /dev/sdc and then used lvm2 command:

sorry, I've missed that before. /dev/sdc is only _one_ of your paths to a LUN. multipath will take the right 2 of those sd* to create one dm device file. Have a look if there's somethign in /dev/mapper, also check your udev rules, you need this line in there:

KERNEL=="dm-[0-9]*", PROGRAM="/sbin/devmap_name %M %m", NAME="%k", SYMLINK="%c"

most distros have a line like
#KERNEL=="dm-[0-9]*", NAME=""
in there, you need to comment it out if you add the lien above.

Quoted 5 lines

Hope that helped,

best regards

Bernd Zeimetz

Bernd,

I haven't had a chance to work on this for a couple of days but I did get do some reading. I'm wondering if I'm using the correct driver for this. I have been trying to use the QLogic driver shipped with SLES. Should I be using the non-EMC driver from the Qlogic website?

Regards,
John

#1 lore raw

hi,

Quoted 3 lines

I haven't had a chance to work on this for a couple of days but I did get do some reading. I'm wondering if I'm using the correct driver for this. I have been trying to use the QLogic driver shipped with SLES.

they should work fine (I hope...). But did you check what I've written in my last mail?

Best regards,

Bernd