Multipath and SAN Fabric failover
[email protected] wrote on 09/10/2006 03:23:55 PM:
Quoted 17 lines
Heya,
Quoted 3 lines
Just to make sure that I've covered everything I partitioned the disk as
/dev/sdcand then used lvm2 command:sorry, I've missed that before.
/dev/sdcis only _one_ of your paths to a LUN. multipath will take the right 2 of those sd* to create one dm device file. Have a look if there's somethign in/dev/mapper, also check your udev rules, you need this line in there:KERNEL=="dm-[0-9]*", PROGRAM="/sbin/devmap_name %M %m", NAME="%k", SYMLINK="%c"
most distros have a line like
#KERNEL=="dm-[0-9]*", NAME=""
in there, you need to comment it out if you add the lien above.
Quoted 5 lines
Hope that helped,
best regards
Bernd Zeimetz
Bernd,
I haven't had a chance to work on this for a couple of days but I did get do some reading. I'm wondering if I'm using the correct driver for this. I have been trying to use the QLogic driver shipped with SLES. Should I be using the non-EMC driver from the Qlogic website?
Regards,
John
hi,
Quoted 3 lines
I haven't had a chance to work on this for a couple of days but I did get do some reading. I'm wondering if I'm using the correct driver for this. I have been trying to use the QLogic driver shipped with SLES.
they should work fine (I hope...). But did you check what I've written in my last mail?
Best regards,