multipath with dual Compaq SA462 connected to MSA500

DISCUSSION Andreas Huck 3 participants 5 messages Oct 10, 2006 – Oct 14, 2006 Device mapper

lore
Share & tools
lore
#0 lore raw

Hi,

I'd like to enable some sort of multipath to a RAID device which is connected by two Smart Array 462 to a MSA500. The host is a DL380 G4. In contrast to MSA1000 the MSA500 is just directly attached, no HBA involved.
The RAID appears as /dev/cciss/c1d0 and /dev/cciss/c2d0 and currently I am forced to disable one path by lvm filter.

Without the lvm filter I get:

Found duplicate PV iXZqRZZg8X6pNn4RBrxRbFiK8O6txY0b: using /dev/cciss/c2d0p1 not /dev/cciss/c1d0p1

So, I'd like to use both controllers but setup multipath on them. Anyone around who succeeded with such a setup? It should work since HP offers some Win*** driver for it, but I need to enable it with SLES9-SP3++ ;-)

The drives do not register as scis defices and to not appear in /proc/scsi/scsi. Therefore, /sbin/scsi_id -g -u -s /block/%n does not work of course.

# multipath -v2 -d
dm names   N
dm table vgdata-netview  N
dm table vglocal-tivoli  N
dm table vgdata-oradata  N
dm table vglocal-tmp  N
dm table vglocal-optoracle  N
dm table vgdata-etc_tivoli  N
dm table vglocal-var  N

So just the LVM devices appear, vgdata is on the MSA500.

Any hints apprecciated!

Thanks and best regards,
Andreas Huck

#1 lore raw

Hi,

Quoted 8 lines · Andreas Huck

I'd like to enable some sort of multipath to a RAID device which is connected by two Smart Array 462 to a MSA500. The host is a DL380 G4. In contrast to MSA1000 the MSA500 is just directly attached, no HBA involved.
The RAID appears as /dev/cciss/c1d0 and /dev/cciss/c2d0 and currently I am forced to disable one path by lvm filter.

well, HP recommends the rather deprecated dm-multipath (on SLES9-SP3).
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00182786/c00182786.pdf
I recall the old raidtab configuration...

Regards,
Andreas

#2 lore raw

Hi,

Quoted 3 lines

well, HP recommends the rather deprecated dm-multipath (on SLES9-SP3).

I think you mean md-multipath.

;)

Cheers,

Bernd

#3 lore raw

Hi,

Quoted 6 lines · Bernd Zeimetz

Hi,

Quoted 3 lines

well, HP recommends the rather deprecated dm-multipath (on SLES9-SP3).

I think you mean md-multipath.

sure, thanks for comment!

Regards,
Andreas

Quoted 2 lines

;)

#4 lore raw
In reply to Andreas Huck
Quoted 3 lines · Andreas Huck

The drives do not register as scis defices and to not appear in /proc/scsi/scsi. Therefore, /sbin/scsi_id -g -u -s /block/%n does not work of course.

/sbin/scsi_id .... is only one of the possible getuid_callout you can just change it to something else or even write your own

L.

Signature · 6 lines
Luca Berra -- [email protected]
       Communication Media & Services S.r.l.
/"\
\ /     ASCII RIBBON CAMPAIGN
 X        AGAINST HTML MAIL
/ \