multipath with dual Compaq SA462 connected to MSA500
Hi,
I'd like to enable some sort of multipath to a RAID device which is connected by two Smart Array 462 to a MSA500. The host is a DL380 G4. In contrast to MSA1000 the MSA500 is just directly attached, no HBA involved.
The RAID appears as /dev/cciss/c1d0 and /dev/cciss/c2d0 and currently I am forced to disable one path by lvm filter.
Without the lvm filter I get:
Found duplicate PV iXZqRZZg8X6pNn4RBrxRbFiK8O6txY0b: using /dev/cciss/c2d0p1 not /dev/cciss/c1d0p1
So, I'd like to use both controllers but setup multipath on them. Anyone around who succeeded with such a setup? It should work since HP offers some Win*** driver for it, but I need to enable it with SLES9-SP3++ ;-)
The drives do not register as scis defices and to not appear in /proc/scsi/scsi. Therefore, /sbin/scsi_id -g -u -s /block/%n does not work of course.
# multipath -v2 -d dm names N dm table vgdata-netview N dm table vglocal-tivoli N dm table vgdata-oradata N dm table vglocal-tmp N dm table vglocal-optoracle N dm table vgdata-etc_tivoli N dm table vglocal-var N
So just the LVM devices appear, vgdata is on the MSA500.
Any hints apprecciated!
Thanks and best regards,
Andreas Huck
Hi,
Quoted 8 lines · Andreas Huck
I'd like to enable some sort of multipath to a RAID device which is connected by two Smart Array 462 to a MSA500. The host is a DL380 G4. In contrast to MSA1000 the MSA500 is just directly attached, no HBA involved.
The RAID appears as/dev/cciss/c1d0and/dev/cciss/c2d0and currently I am forced to disable one path by lvm filter.
well, HP recommends the rather deprecated dm-multipath (on SLES9-SP3).
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00182786/c00182786.pdf
I recall the old raidtab configuration...
Regards,
Andreas
Hi,
Quoted 3 lines
well, HP recommends the rather deprecated dm-multipath (on SLES9-SP3).
I think you mean md-multipath.
;)
Cheers,
Bernd
Hi,
Quoted 6 lines · Bernd Zeimetz
Hi,
Quoted 3 lines
well, HP recommends the rather deprecated dm-multipath (on SLES9-SP3).
I think you mean md-multipath.
sure, thanks for comment!
Regards,
Andreas
Quoted 2 lines
;)
Quoted 3 lines · Andreas Huck
The drives do not register as scis defices and to not appear in
/proc/scsi/scsi. Therefore,/sbin/scsi_id-g -u -s /block/%n does not work of course.
/sbin/scsi_id .... is only one of the possible getuid_callout you can just change it to something else or even write your own
L.
Signature · 6 lines
Luca Berra -- [email protected] Communication Media & Services S.r.l. /"\ \ / ASCII RIBBON CAMPAIGN X AGAINST HTML MAIL / \