UBI: Ensure that "background thread" operations are really executed

PATCH New Stefan Roese 1 participant 2 messages May 17, 2010 – May 19, 2010

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH 1/1 UBI: Ensure that "background thread" operations are really executed

The current U-Boot UBI implementation is copied from Linux. In this porting the UBI background thread was not handled correctly. Upon write operations ubi_wl_flush() makes sure, that all queued operations, like page-erase, are completed. But this is missing for read operations.

This patch now makes sure that such operations (like scrubbing upon bit-flip errors) are not queued, but executed directly.

---
 drivers/mtd/ubi/wl.c |    9 +++++++--
 1 files changed, 7 insertions(+), 2 deletions(-)
drivers/mtd/ubi/wl.c +7 -2
index 2f9a5e3..88b867a 100644
@@ -696,8 +696,13 @@ static void schedule_ubi_work(struct ubi_device *ubi, struct ubi_work *wrk)
 	list_add_tail(&wrk->list, &ubi->works);
 	ubi_assert(ubi->works_count >= 0);
 	ubi->works_count += 1;
-	if (ubi->thread_enabled)
-		wake_up_process(ubi->bgt_thread);
+
+	/*
+	 * U-Boot special: We have no bgt_thread in U-Boot!
+	 * So just call do_work() here directly.
+	 */
+	do_work(ubi);
+
 	spin_unlock(&ubi->wl_lock);
 }
 
Signature · 1 line
1.7.1
#1 lore raw

PATCH 1/1 UBI: Ensure that "background thread" operations are really executed

Quoted 7 lines · On Monday 17 May 2010 10:00:51 Stefan Roese wrote:

The current U-Boot UBI implementation is copied from Linux. In this porting the UBI background thread was not handled correctly. Upon write operations ubi_wl_flush() makes sure, that all queued operations, like page-erase, are completed. But this is missing for read operations.

This patch now makes sure that such operations (like scrubbing upon bit-flip errors) are not queued, but executed directly.

Applied to u-boot-ubi/master. Thanks.

Cheers,
Stefan

--
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-0 Fax: (+49)-8142-66989-80 Email: office at denx.de