PATCH 1/1 xen-netfront: report link speed to ethtool

Add .get_settings function, return fake data so that ethtool can get enough information. For some application like VCS, this is useful, otherwise some of application logic will get panic.
The reported data refers to VMWare vmxnet.

---
 drivers/net/xen-netfront.c |   12 ++++++++++++
 1 file changed, 12 insertions(+)
drivers/net/xen-netfront.c +12 -0
Index: linux-3.2-rc2/drivers/net/xen-netfront.c
===================================================================
@@ -1727,6 +1727,17 @@ static void netback_changed(struct xenbu
 	}
 }
 
+static int xennet_get_settings(struct net_device *netdev, struct ethtool_cmd *ecmd)
+{
+	ecmd->supported = SUPPORTED_1000baseT_Full | SUPPORTED_TP;
+	ecmd->advertising = ADVERTISED_TP;
+	ecmd->port = PORT_TP;
+	ecmd->transceiver = XCVR_INTERNAL;
+	ecmd->speed = SPEED_1000;
+	ecmd->duplex = DUPLEX_FULL;
+	return 0;
+}
+
 static const struct xennet_stat {
 	char name[ETH_GSTRING_LEN];
 	u16 offset;
@@ -1774,6 +1785,7 @@ static const struct ethtool_ops xennet_e
 {
 	.get_link = ethtool_op_get_link,
 
+	.get_settings = xennet_get_settings,
 	.get_sset_count = xennet_get_sset_count,
 	.get_ethtool_stats = xennet_get_ethtool_stats,
 	.get_strings = xennet_get_strings,
#1 lore raw
Quoted 8 lines · Olaf Hering

Add .get_settings function, return fake data so that ethtool can get enough information. For some application like VCS, this is useful, otherwise some of application logic will get panic.
The reported data refers to VMWare vmxnet.

NAK, we should not just make things up.

Ben.

Quoted 38 lines
---
 drivers/net/xen-netfront.c |   12 ++++++++++++
 1 file changed, 12 insertions(+)

Index: linux-3.2-rc2/drivers/net/xen-netfront.c
===================================================================

drivers/net/xen-netfront.c +12 -1
@@ -1727,6 +1727,17 @@ static void netback_changed(struct xenbu
 	}
 }
 
+static int xennet_get_settings(struct net_device *netdev, struct ethtool_cmd *ecmd)
+{
+	ecmd->supported = SUPPORTED_1000baseT_Full | SUPPORTED_TP;
+	ecmd->advertising = ADVERTISED_TP;
+	ecmd->port = PORT_TP;
+	ecmd->transceiver = XCVR_INTERNAL;
+	ecmd->speed = SPEED_1000;
+	ecmd->duplex = DUPLEX_FULL;
+	return 0;
+}
+
 static const struct xennet_stat {
 	char name[ETH_GSTRING_LEN];
 	u16 offset;
@@ -1774,6 +1785,7 @@ static const struct ethtool_ops xennet_e
 {
 	.get_link = ethtool_op_get_link,
 
+	.get_settings = xennet_get_settings,
 	.get_sset_count = xennet_get_sset_count,
 	.get_ethtool_stats = xennet_get_ethtool_stats,
 	.get_strings = xennet_get_strings,
--

To unsubscribe from this list: send the line "unsubscribe netdev" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

Signature · 3 lines
Ben Hutchings, Staff Engineer, Solarflare
Not speaking for my employer; that's the marketing department's job.
They asked us to note that Solarflare product names are trademarked.
#2 lore raw
Quoted 3 lines · Ben Hutchings
Quoted 1 line · Olaf Hering

The reported data refers to VMWare vmxnet.

NAK, we should not just make things up.

So how about removing veth_get_settings, vmxnet3_get_settings, tun_get_settings and other functions that escaped my grep?

Olaf

#3 lore raw
Quoted 8 lines · Olaf Hering
Quoted 3 lines · Ben Hutchings
Quoted 1 line · Olaf Hering

The reported data refers to VMWare vmxnet.

NAK, we should not just make things up.

So how about removing veth_get_settings, vmxnet3_get_settings, tun_get_settings and other functions that escaped my grep?

If they can't provide meaningful information then maybe they should be removed. However, that could result in a regression for existing working configurations. (This isn't the same as the case you're trying to fix, since those applications have never worked with xen-netfront or many other drivers that don't implement get_settings.)

Ben.

Signature · 3 lines
Ben Hutchings, Staff Engineer, Solarflare
Not speaking for my employer; that's the marketing department's job.
They asked us to note that Solarflare product names are trademarked.
#4 lore raw
Quoted 7 lines · Ben Hutchings
Quoted 6 lines · Olaf Hering
Quoted 3 lines · Ben Hutchings
Quoted 1 line · Olaf Hering

The reported data refers to VMWare vmxnet.

NAK, we should not just make things up.

Quoted 8 lines
Quoted 2 lines

So how about removing veth_get_settings, vmxnet3_get_settings, tun_get_settings and other functions that escaped my grep?

If they can't provide meaningful information then maybe they should be removed. However, that could result in a regression for existing working configurations. (This isn't the same as the case you're trying to fix, since those applications have never worked with xen-netfront or many other drivers that don't implement get_settings.)

That may be.
How about a new generic ethtool_op_get_settings_veth which returns fake values for all relevant drivers (virtio, xen-netfront, and the ones listed above)?

Olaf

#5 lore raw
In reply to Ben Hutchings
Quoted 11 lines · Ben Hutchings
Quoted 8 lines · Olaf Hering

Add .get_settings function, return fake data so that ethtool can get enough information. For some application like VCS, this is useful, otherwise some of application logic will get panic.
The reported data refers to VMWare vmxnet.

NAK, we should not just make things up.

Which raises an interesting question for a virtual interface that isn't pretending to be a specific NIC type. What should the reported speed be?
Is it a 10/100 NIC? A 1 or 10 GbE NIC? 3.14 GbE? For other emulated
interfaces, it rather falls-out from the emulation. We can say that the driver may not make stuff up, but it would seem what is running in the host/hypervisor/dom0/whatever will have to. It could I suppose, decide based on the physical NIC to which it is attached, so long as folks using the virtual NIC don't expect its attributes to be the same from system to system.

rick

#6 lore raw
Quoted 4 lines · Rick Jones

It could I suppose, decide
based on the physical NIC to which it is attached, so long as folks using the virtual NIC don't expect its attributes to be the same from system to system.

And assuming there's a physical NIC at all.

J

#7 lore raw

use a special value of -2 for virtual devices to report indeterminate speed?

Quoted 7 lines · Jeremy Fitzhardinge
Quoted 4 lines · Rick Jones

It could I suppose, decide
based on the physical NIC to which it is attached, so long as folks using the virtual NIC don't expect its attributes to be the same from system to system.

And assuming there's a physical NIC at all.

It sounds like we need a way to specify "Indeterminate" for link speed?
Or some verbiage to that effect. Right now 0 and -1 cause ethtool to
report "Unknown!"

        if (speed == 0 || speed == (u16)(-1) || speed == (u32)(-1))
                fprintf(stdout, "Unknown!\n");
        else
                fprintf(stdout, "%uMb/s\n", speed);

How about -2 for the u32 cast value of speed returning "Indeterminate" or something like that? Not in "proper" patch format:

	if (speed == 0 || speed == (u16)(-1) || speed == (u32)(-1))
		fprintf(stdout, "Unknown!\n");
	else if (speed == (u32)(-2))
		fprintf(stdout, "Indeterminate.");
	else
		fprintf(stdout, "%uMb/s\n", speed);

rick jones

#8 lore raw

Re: use a special value of -2 for virtual devices to report indeterminate speed?

Quoted 22 lines · Rick Jones
Quoted 7 lines · Jeremy Fitzhardinge
Quoted 4 lines · Rick Jones

It could I suppose, decide
based on the physical NIC to which it is attached, so long as folks using the virtual NIC don't expect its attributes to be the same from system to system.

And assuming there's a physical NIC at all.

It sounds like we need a way to specify "Indeterminate" for link speed?
Or some verbiage to that effect. Right now 0 and -1 cause ethtool to
report "Unknown!"

         if (speed == 0 || speed == (u16)(-1) || speed == (u32)(-1))
                 fprintf(stdout, "Unknown!\n");
         else
                 fprintf(stdout, "%uMb/s\n", speed);

How about -2 for the u32 cast value of speed returning "Indeterminate" or something like that? Not in "proper" patch format:

Quoted 6 lines
	if (speed == 0 || speed == (u16)(-1) || speed == (u32)(-1))
		fprintf(stdout, "Unknown!\n");
	else if (speed == (u32)(-2))
		fprintf(stdout, "Indeterminate.");
	else
		fprintf(stdout, "%uMb/s\n", speed);

I'm open to something like this, but the problem with assigning new magic numbers is that older versions of ethtool won't know to report them as special.

We should also consider stacked drivers like bonding (and presumably team) that expect real numbers when the link is up.

Ben.

Signature · 3 lines
Ben Hutchings, Staff Engineer, Solarflare
Not speaking for my employer; that's the marketing department's job.
They asked us to note that Solarflare product names are trademarked.
#9 lore raw
In reply to Rick Jones
Quoted 23 lines · On Fri 18. of November 2011 19:44:08 you wrote:
Quoted 11 lines · Ben Hutchings
Quoted 8 lines · Olaf Hering

Add .get_settings function, return fake data so that ethtool can get enough information. For some application like VCS, this is useful, otherwise some of application logic will get panic.
The reported data refers to VMWare vmxnet.

NAK, we should not just make things up.

Which raises an interesting question for a virtual interface that isn't pretending to be a specific NIC type. What should the reported speed be?
Is it a 10/100 NIC? A 1 or 10 GbE NIC? 3.14 GbE? For other emulated
interfaces, it rather falls-out from the emulation. We can say that the driver may not make stuff up, but it would seem what is running in the host/hypervisor/dom0/whatever will have to. It could I suppose, decide based on the physical NIC to which it is attached, so long as folks using the virtual NIC don't expect its attributes to be the same from system to system.

Quoted 1 line

rick

Hmm,
two questions from me.
I think there is 10GbE link reported in Windows gplpv 0.11.0.322 driver. Let say I have two virtual Windows running on XEN and they are in bridge with 1GbE physical NIC.
Will the Windows talk to each other on 10GbE thru the bridge? What should I do to give them 10GbE access to local samba server?

Signature · 1 line
Pavel Mateja
#10 lore raw
Quoted 26 lines · Pavel Mat??ja
Quoted 23 lines · On Fri 18. of November 2011 19:44:08 you wrote:
Quoted 11 lines · Ben Hutchings
Quoted 8 lines · Olaf Hering

Add .get_settings function, return fake data so that ethtool can get enough information. For some application like VCS, this is useful, otherwise some of application logic will get panic.
The reported data refers to VMWare vmxnet.

NAK, we should not just make things up.

Which raises an interesting question for a virtual interface that isn't pretending to be a specific NIC type. What should the reported speed be?
Is it a 10/100 NIC? A 1 or 10 GbE NIC? 3.14 GbE? For other emulated
interfaces, it rather falls-out from the emulation. We can say that the driver may not make stuff up, but it would seem what is running in the host/hypervisor/dom0/whatever will have to. It could I suppose, decide based on the physical NIC to which it is attached, so long as folks using the virtual NIC don't expect its attributes to be the same from system to system.

Quoted 1 line

rick

Quoted 8 lines

Hmm,
two questions from me.
I think there is 10GbE link reported in Windows gplpv 0.11.0.322 driver. Let say I have two virtual Windows running on XEN and they are in bridge with 1GbE physical NIC.
Will the Windows talk to each other on 10GbE thru the bridge? What should I do to give them 10GbE access to local samba server?

The reported NIC speed in the VM does not mean anything really,
because it's all virtual "hardware", and the reported speed is not any kind of limit.

Even if windows VM says it's 10 Mbit/sec NIC you can still talk as fast as your system can go.

-- Pasi

#11 lore raw
Quoted 6 lines

The reported NIC speed in the VM does not mean anything really, because it's all virtual "hardware", and the reported speed is not any kind of limit.

Even if windows VM says it's 10 Mbit/sec NIC you can still talk as fast as your system can go.

That's not quite true. Windows or some application might equate 10Mbit == WAN and do things a bit differently. BITS certainly scales back throughput but I think it does that based on actual tested throughput, although it might use the link speed as an indication.

A HVM domain needs to report something because it is emulated hardware. A way to pass that through from Dom0 would be nice, but probably a lot of work for little gain vs just making up a reasonable figure.

James

#12 lore raw
In reply to Pavel Matěja
Quoted 8 lines

Hmm,
two questions from me.
I think there is 10GbE link reported in Windows gplpv 0.11.0.322 driver. Let say I have two virtual Windows running on XEN and they are in bridge with 1GbE physical NIC.
Will the Windows talk to each other on 10GbE thru the bridge? What should I do to give them 10GbE access to local samba server?

I've never had GPLPV talking at 10Gb, but it can easily do 2-4Gb to Dom0 or another DomU, so reporting a 1Gb figure is aiming a little low. Windows basically demands that you give a value, and Hyper-V reports 10Gb so I do too.

James

maintainer
#13 lore raw
In reply to Ben Hutchings

From: Ben Hutchings <[email protected]>
Date: Fri, 18 Nov 2011 17:46:34 +0000

Quoted 11 lines · Olaf Hering
Quoted 8 lines

Add .get_settings function, return fake data so that ethtool can get enough information. For some application like VCS, this is useful, otherwise some of application logic will get panic.
The reported data refers to VMWare vmxnet.

NAK, we should not just make things up.

Agreed, if you cannot determine the values with certainty do not implement this method.

Fix the tools which cannot function without this information.