mx28: fix clearing of IRQs in power init

PATCH New Zach Sadecki 3 participants 3 messages Jan 9, 2012 – Jan 11, 2012 Arm (32-bit)

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 mx28: fix clearing of IRQs in power init

There are 2 locations in the power init code for the mx28 where IRQs are not being cleared because incorrect methods to clear those bits were being used. This was causing my board to get stuck waiting for POWER_CTRL_VDD5V_DROOP_IRQ to clear. Using the correct method to clear the IRQs fixes it.

Cc Wolfgang Denk <[email protected]>
Cc Stefano Babic <[email protected]>
---
 arch/arm/cpu/arm926ejs/mx28/spl_power_init.c |    8 ++++----
 1 files changed, 4 insertions(+), 4 deletions(-)
arch/arm/cpu/arm926ejs/mx28/spl_power_init.c +4 -4
index a4dc2a3..380b120 100644
@@ -240,8 +240,8 @@ void mx28_enable_4p2_dcdc_input(int xfer)
 		clrbits_le32(&power_regs->hw_power_minpwr, POWER_MINPWR_PWD_BO);
 
 	while (readl(&power_regs->hw_power_ctrl) & POWER_CTRL_VBUS_VALID_IRQ)
-		clrbits_le32(&power_regs->hw_power_ctrl,
-				POWER_CTRL_VBUS_VALID_IRQ);
+		writel(POWER_CTRL_VBUS_VALID_IRQ,
+			&power_regs->hw_power_ctrl_clr);
 
 	if (prev_5v_brnout) {
 		writel(POWER_5VCTRL_PWDN_5VBRNOUT,
@@ -256,8 +256,8 @@ void mx28_enable_4p2_dcdc_input(int xfer)
 	}
 
 	while (readl(&power_regs->hw_power_ctrl) & POWER_CTRL_VDD5V_DROOP_IRQ)
-		clrbits_le32(&power_regs->hw_power_ctrl,
-				POWER_CTRL_VDD5V_DROOP_IRQ);
+		writel(POWER_CTRL_VDD5V_DROOP_IRQ,
+			&power_regs->hw_power_ctrl_clr);
 
 	if (prev_5v_droop)
 		clrbits_le32(&power_regs->hw_power_ctrl,
#1 lore raw

PATCH 1/1 mx28: fix clearing of IRQs in power init

Quoted 30 lines

There are 2 locations in the power init code for the mx28 where IRQs are not being cleared because incorrect methods to clear those bits were being used. This was causing my board to get stuck waiting for POWER_CTRL_VDD5V_DROOP_IRQ to clear. Using the correct method to clear the IRQs fixes it.

Cc Wolfgang Denk <[email protected]>
Cc Stefano Babic <[email protected]>
---
 arch/arm/cpu/arm926ejs/mx28/spl_power_init.c |    8 ++++----
 1 files changed, 4 insertions(+), 4 deletions(-)
(quoted diff) +0 -0

b/arch/arm/cpu/arm926ejs/mx28/spl_power_init.c index a4dc2a3..380b120 100644

arch/arm/cpu/arm926ejs/mx28/spl_power_init.c +2 -2
@@ -240,8 +240,8 @@ void mx28_enable_4p2_dcdc_input(int xfer)
 		clrbits_le32(&power_regs->hw_power_minpwr, POWER_MINPWR_PWD_BO);
 
 	while (readl(&power_regs->hw_power_ctrl) & POWER_CTRL_VBUS_VALID_IRQ)
-		clrbits_le32(&power_regs->hw_power_ctrl,
-				POWER_CTRL_VBUS_VALID_IRQ);
+		writel(POWER_CTRL_VBUS_VALID_IRQ,
+			&power_regs->hw_power_ctrl_clr);
 
 	if (prev_5v_brnout) {
 		writel(POWER_5VCTRL_PWDN_5VBRNOUT,

arch/arm/cpu/arm926ejs/mx28/spl_power_init.c void mx28_enable_4p2_dcdc_input(int xfer) · line 263

Quoted 10 lines
arch/arm/cpu/arm926ejs/mx28/spl_power_init.c +2 -2
@@ -256,8 +256,8 @@ void mx28_enable_4p2_dcdc_input(int xfer)
 	}
 
 	while (readl(&power_regs->hw_power_ctrl) & POWER_CTRL_VDD5V_DROOP_IRQ)
-		clrbits_le32(&power_regs->hw_power_ctrl,
-				POWER_CTRL_VDD5V_DROOP_IRQ);
+		writel(POWER_CTRL_VDD5V_DROOP_IRQ,
+			&power_regs->hw_power_ctrl_clr);
 
 	if (prev_5v_droop)
 		clrbits_le32(&power_regs->hw_power_ctrl,

Hello,

this is an impressive catch! I did investigation of the Freescale bootlets code and found out you're right, it's an SCT register. So:

M

#2 lore raw

PATCH 1/1 mx28: fix clearing of IRQs in power init

In reply to Zach Sadecki
Quoted 6 lines · Zach Sadecki

There are 2 locations in the power init code for the mx28 where IRQs are not being cleared because incorrect methods to clear those bits were being used. This was causing my board to get stuck waiting for POWER_CTRL_VDD5V_DROOP_IRQ to clear. Using the correct method to clear the IRQs fixes it.

Cc Wolfgang Denk <[email protected]>
Cc Stefano Babic <[email protected]>

---

Applied to u-boot-imx, thanks.

Best regards,
Stefano Babic

Signature · 5 lines
=====================================================================
DENX Software Engineering GmbH,     MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: +49-8142-66989-0 Fax: +49-8142-66989-80  Email: office at denx.de
=====================================================================