Fix bootdelay timeout calculation when SYS_HZ!=1000
PATCH 1/1 Fix bootdelay timeout calculation when SYS_HZ!=1000
Commit b2f3e0e "console: USB: KBD: Fix incorrect autoboot timeout" re-wrote the bootdelay timeout loop. However, it hard-coded the value that get_delay() was expected to increment in one second, rather than calculating it based on CONFIG_SYS_HZ. On systems where SYS_HZ != 1000, this caused bootdelay timeout to be incorrect. Fix this.
--- common/main.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
common/main.c +1 -1
@@ -264,7 +264,7 @@ int abortboot(int bootdelay)break ; }udelay (10000 ); - }while (!abort &&get_timer (ts) <1000 ); + }while (!abort &&get_timer (ts) <CONFIG_SYS_HZ );printf ("\b\b\b%2d " , bootdelay); }
Signature · 1 line
1.7.10.4
PATCH 1/1 Fix bootdelay timeout calculation when SYS_HZ!=1000
Dear Stephen Warren,
Quoted 5 lines · In message <[email protected]> you wrote:
Commit b2f3e0e "console: USB: KBD: Fix incorrect autoboot timeout" re-wrote the bootdelay timeout loop. However, it hard-coded the value that
get_delay()was expected to increment in one second, rather than calculating it based onCONFIG_SYS_HZ. On systems whereSYS_HZ!= 1000, this caused bootdelay timeout to be incorrect. Fix this.
Are there any such systems left? I agree with your patch, but if you know of systems that use incorrect values of CONFIG_SYS_HZ then please point these out so they can be fixed!
A system with CONFIG_SYS_HZ != 1000 is _broken_.
Best regards,
Wolfgang Denk
Signature · 5 lines
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de It is dangerous to be right on a subject on which the established authorities are wrong. -- Voltaire
PATCH 1/1 Fix bootdelay timeout calculation when SYS_HZ!=1000
-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1
Quoted 11 lines · Wolfgang Denk
Dear Stephen Warren,
In message <[email protected]>
Quoted 6 lines · you
Commit b2f3e0e "console: USB: KBD: Fix incorrect autoboot timeout" re-wrote the bootdelay timeout loop. However, it hard-coded the value that
get_delay()was expected to increment in one second, rather than calculating it based onCONFIG_SYS_HZ. On systems whereSYS_HZ!= 1000, this caused bootdelay timeout to be incorrect. Fix this.
Quoted 5 lines
Are there any such systems left? I agree with your patch, but if you know of systems that use incorrect values of
CONFIG_SYS_HZthen please point these out so they can be fixed!A system with
CONFIG_SYS_HZ!= 1000 is _broken_.
So, RPi is going higher, and Jon hit this on I suspect omap2420h4 which is also higher (after mathing that all out). If we no longer support CONFIG_SYS_HZ != 1000 we need to make that clear (and explain why).
- --
Tom
-----BEGIN PGP SIGNATURE-----
Version: GnuPG v1.4.11 (GNU/Linux)
Comment: Using GnuPG with Thunderbird - http://www.enigmail.net/
iQIcBAEBAgAGBQJRSxA2AAoJENk4IS6UOR1WPzwP/3f+BiTw3s9cWGZKOb4gDza3 n0ke0rZdqLkwixK3Ugl5IqcquTLEh5QZcZb37cGgWQ0N0YvUoIxcBR73mWSHhQgy VMlVU0vtlrGQsFmN0kbouO+qpzyoAkaDidt6T/WxDazgd+CoCuHguXki1peEB/HQ ryQ6yNOog5dFUux85cL+AmWZYRkGXRWJfrIqKHZ9MPvz3TxXjhFBZ4lR+8JwMWgS wPIFhNMTWnIHvXCfbcumFXV0Lgyn0DYnCbKIMLM/NucRKcHX8ZYnX1L8UOGvRzZn jjqKFm95dNvPhZLLAaZI2TmVu5YMR9VZmmZpst0VC3eACkcQ+70G8CA+3ApmTC2C 3FcLnQQnWlG83/3qj23Qc6trLsk17spEIN0GaSy5ow261sbsXotLEsw0K7luaZPM Y6KF5cZSyqQZ9TdnIbVxtcsI0Vwk5lLvtB91qleAJDrqn9o4ugEl0IWcRlwN9t9a DQM0t/P+DotOlLdVQ6elVcimVxBvKLJEMIcdJVyKqsnOQIs9ct9fPm9j03ZRpS9S YlvegCU/n0J25RVtZL6+hpOQa2ZkZOyFg3sZwSLx42jDilvIYemYcGaH21C64prJ HJ7+rnxPvK1lC4DPVP0QoIrQEpgABnTZfDaLsts/z3sq2m4+S9uZHqiwyBJ4luoa ua2LQXAovkSF1FA2kV1I
=VTCE
-----END PGP SIGNATURE-----
PATCH 1/1 Fix bootdelay timeout calculation when SYS_HZ!=1000
Dear Tom,
Quoted 7 lines · In message <[email protected]> you wrote:
Quoted 2 lines
A system with
CONFIG_SYS_HZ!= 1000 is _broken_.So, RPi is going higher, and Jon hit this on I suspect omap2420h4 which is also higher (after mathing that all out). If we no longer support
CONFIG_SYS_HZ!= 1000 we need to make that clear (and explain why).
It has never been supported, so this is not a case of "no longer". There are several longish threads (about the timer code, especially on ARM) in the archives.
Best regards,
Wolfgang Denk
Signature · 4 lines
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de "The whole world is about three drinks behind." - Humphrey Bogart
PATCH 1/1 Fix bootdelay timeout calculation when SYS_HZ!=1000
Quoted 6 lines · Wolfgang Denk
Dear Tom,
Quoted 3 lines · In message <[email protected]> you wrote:
Quoted 2 lines
A system with
CONFIG_SYS_HZ!= 1000 is _broken_.
Quoted 8 lines
Quoted 4 lines
So, RPi is going higher, and Jon hit this on I suspect omap2420h4 which is also higher (after mathing that all out). If we no longer support
CONFIG_SYS_HZ!= 1000 we need to make that clear (and explain why).It has never been supported, so this is not a case of "no longer". There are several longish threads (about the timer code, especially on ARM) in the archives.
OK, then we need to do something about these platforms today. I'm guessing RPi can just be tuned down to 1000 but for omap2420h4 it's an interesting value and I don't know about the platform well enough to say what we'd need to do to adapt it. Jon?
Signature · 8 lines
Tom -------------- next part -------------- A non-text attachment was scrubbed... Name: not available Type: application/pgp-signature Size: 836 bytes Desc: Digital signature URL: <http://lists.denx.de/pipermail/u-boot/attachments/20130321/17cd67b6/attachment.pgp>
PATCH 1/1 Fix bootdelay timeout calculation when SYS_HZ!=1000
Quoted 12 lines · Tom Rini
Quoted 11 lines · Wolfgang Denk
Dear Tom,
Quoted 7 lines · In message <[email protected]> you wrote:
Quoted 2 lines
A system with
CONFIG_SYS_HZ!= 1000 is _broken_.So, RPi is going higher, and Jon hit this on I suspect omap2420h4 which is also higher (after mathing that all out). If we no longer support
CONFIG_SYS_HZ!= 1000 we need to make that clear (and explain why).
Quoted 8 lines
Quoted 3 lines
It has never been supported, so this is not a case of "no longer". There are several longish threads (about the timer code, especially on ARM) in the archives.
OK, then we need to do something about these platforms today. I'm guessing RPi can just be tuned down to 1000 but for omap2420h4 it's an interesting value and I don't know about the platform well enough to say what we'd need to do to adapt it. Jon?
For OMAP2420, we have a choice of using either a 12MHz or 32kHz clock to drive the timer. With the 32kHz clock we can get close to 1000Hz tick but we cannot get it dead on. That's why OMAP has been using 128Hz tick in the kernel as opposed to 100Hz tick in the kernel for years (although that was changed recently).
Cheers
Jon
PATCH 1/1 Fix bootdelay timeout calculation when SYS_HZ!=1000
-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1
Quoted 24 lines · Jon Hunter
Quoted 16 lines · Tom Rini
Quoted 6 lines · Wolfgang Denk
Dear Tom,
Quoted 3 lines · In message <[email protected]> you wrote:
Quoted 2 lines
A system with
CONFIG_SYS_HZ!= 1000 is _broken_.Quoted 8 lines
Quoted 4 lines
So, RPi is going higher, and Jon hit this on I suspect omap2420h4 which is also higher (after mathing that all out). If we no longer support
CONFIG_SYS_HZ!= 1000 we need to make that clear (and explain why).It has never been supported, so this is not a case of "no longer". There are several longish threads (about the timer code, especially on ARM) in the archives.
Quoted 5 lines
OK, then we need to do something about these platforms today. I'm guessing RPi can just be tuned down to 1000 but for omap2420h4 it's an interesting value and I don't know about the platform well enough to say what we'd need to do to adapt it. Jon?
Quoted 5 lines
For OMAP2420, we have a choice of using either a 12MHz or 32kHz clock to drive the timer. With the 32kHz clock we can get close to 1000Hz tick but we cannot get it dead on. That's why OMAP has been using 128Hz tick in the kernel as opposed to 100Hz tick in the kernel for years (although that was changed recently).
The rest of the OMAP/related platforsm in U-Boot accept that as "good" enough I guess since they've been setting to 1000 for a while / since they went in (depending on the platform in particular). So if you have time to whack 2420 over and give it some quick testing I'd appreciate it. Thanks!
- --
Tom
-----BEGIN PGP SIGNATURE-----
Version: GnuPG v1.4.11 (GNU/Linux)
Comment: Using GnuPG with Thunderbird - http://www.enigmail.net/
iQIcBAEBAgAGBQJRSycGAAoJENk4IS6UOR1WXIQQAIZOPSG04jMTavV8rBykXnjL WQAvUmnGeAs7A2sMXfq+1HhXkLK/hMKHYR5IRLEx0asYuOXZ+sls9oPBxwpXHYQq zMRcoEZRbWkz/Ell0Pe6gyN4LesCvTd+Zt+nV/Rs+oO0o3ITtqYOzTNOfaNwyftC xXBUCXi9ecMnKhJb00IrAuELvU1kyb54v9tuJQNkw6ML0cWxTQiQFgzfMT8lRf/E DwSaDxdQEi4+CzmXDE7VClx0P5R5GDd3NhtaQ8lz9w6mPoJ/GyFmYI4PIWAqsscO ryRyrJlPx0KusmMZrtVMdBJqeXi4rU1vsrAqHsbntPWTt7WznyHOdELDtSoUbwHE WotIW3+xqckNKNYjPYpWU1syRlWUqPK+wbHfB0bEVEtdPNQCBJ/jT34c/Ur4V7fn aAJkhaimH/oWKtBiZD2hEUKZzsILrUpH0mk0S4xra5mHVDacypaeJ6xK1h0vkZTw CoRHXH05JZlLJf1NXP3lRg/b8NUEH4Z/nGvQpmHUOySgPiGYs1CQx6f+3A8P2Rrd W9TQ+fSWxtRzRUuHf18QdYFP5MCvWwgRuvquxsqlUAULzWYbisSb66TUY4vOyYZG 6htN9/wZEinsbmGlx6yTA6RBijSMP3kpSswwyN/Y1AHNP04MQO+Gflii9NvdtsRM 1jQ6as+M3YHCh7jAdINj
=yJ2h
-----END PGP SIGNATURE-----
PATCH 1/1 Fix bootdelay timeout calculation when SYS_HZ!=1000
Quoted 34 lines · Tom Rini
-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1Quoted 24 lines · Jon Hunter
Quoted 16 lines · Tom Rini
Quoted 6 lines · Wolfgang Denk
Dear Tom,
Quoted 3 lines · In message <[email protected]> you wrote:
Quoted 2 lines
A system with
CONFIG_SYS_HZ!= 1000 is _broken_.Quoted 8 lines
Quoted 4 lines
So, RPi is going higher, and Jon hit this on I suspect omap2420h4 which is also higher (after mathing that all out). If we no longer support
CONFIG_SYS_HZ!= 1000 we need to make that clear (and explain why).It has never been supported, so this is not a case of "no longer". There are several longish threads (about the timer code, especially on ARM) in the archives.
Quoted 5 lines
OK, then we need to do something about these platforms today. I'm guessing RPi can just be tuned down to 1000 but for omap2420h4 it's an interesting value and I don't know about the platform well enough to say what we'd need to do to adapt it. Jon?
Quoted 5 lines
For OMAP2420, we have a choice of using either a 12MHz or 32kHz clock to drive the timer. With the 32kHz clock we can get close to 1000Hz tick but we cannot get it dead on. That's why OMAP has been using 128Hz tick in the kernel as opposed to 100Hz tick in the kernel for years (although that was changed recently).
Quoted 5 lines
The rest of the OMAP/related platforsm in U-Boot accept that as "good" enough I guess since they've been setting to 1000 for a while / since they went in (depending on the platform in particular). So if you have time to whack 2420 over and give it some quick testing I'd appreciate it. Thanks!
Looks like the OMAP timers are running faster than 1000Hz but the timer tick rate is being normalised to 1000Hz by dividing the actual timer rate by SYS_HZ. I see ...
readl(&timer_base->tcrr) / (TIMER_CLOCK / CONFIG_SYS_HZ);
We could do the same for OMAP2420. In fact we could move arch/arm/cpu/armv7/omap-common/timer.c to arch/arm/omap-common/timer.c and use this for OMAP2420. The legacy OMAP2420 code is very similar to this.
Jon
PATCH 1/1 Fix bootdelay timeout calculation when SYS_HZ!=1000
Quoted 46 lines · Jon Hunter
Quoted 34 lines · Tom Rini
-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1Quoted 24 lines · Jon Hunter
Quoted 16 lines · Tom Rini
Quoted 6 lines · Wolfgang Denk
Dear Tom,
Quoted 3 lines · In message <[email protected]> you wrote:
Quoted 2 lines
A system with
CONFIG_SYS_HZ!= 1000 is _broken_.Quoted 8 lines
Quoted 4 lines
So, RPi is going higher, and Jon hit this on I suspect omap2420h4 which is also higher (after mathing that all out). If we no longer support
CONFIG_SYS_HZ!= 1000 we need to make that clear (and explain why).It has never been supported, so this is not a case of "no longer". There are several longish threads (about the timer code, especially on ARM) in the archives.
Quoted 5 lines
OK, then we need to do something about these platforms today. I'm guessing RPi can just be tuned down to 1000 but for omap2420h4 it's an interesting value and I don't know about the platform well enough to say what we'd need to do to adapt it. Jon?
Quoted 5 lines
For OMAP2420, we have a choice of using either a 12MHz or 32kHz clock to drive the timer. With the 32kHz clock we can get close to 1000Hz tick but we cannot get it dead on. That's why OMAP has been using 128Hz tick in the kernel as opposed to 100Hz tick in the kernel for years (although that was changed recently).
Quoted 5 lines
The rest of the OMAP/related platforsm in U-Boot accept that as "good" enough I guess since they've been setting to 1000 for a while / since they went in (depending on the platform in particular). So if you have time to whack 2420 over and give it some quick testing I'd appreciate it. Thanks!
Looks like the OMAP timers are running faster than 1000Hz but the timer tick rate is being normalised to 1000Hz by dividing the actual timer rate by
SYS_HZ. I see ...
Quoted 5 lines
readl(&timer_base->tcrr) / (TIMER_CLOCK / CONFIG_SYS_HZ);We could do the same for OMAP2420. In fact we could move
arch/arm/cpu/armv7/omap-common/timer.ctoarch/arm/omap-common/timer.cand use this for OMAP2420. The legacy OMAP2420 code is very similar to this.
Sounds good to me, thanks!
Signature · 8 lines
Tom -------------- next part -------------- A non-text attachment was scrubbed... Name: not available Type: application/pgp-signature Size: 836 bytes Desc: Digital signature URL: <http://lists.denx.de/pipermail/u-boot/attachments/20130321/c817959c/attachment.pgp>
PATCH 1/1 Fix bootdelay timeout calculation when SYS_HZ!=1000
In reply to Wolfgang DenkQuoted 9 lines · Wolfgang Denk
Dear Stephen Warren,
Quoted 5 lines · In message <[email protected]> you wrote:
Commit b2f3e0e "console: USB: KBD: Fix incorrect autoboot timeout" re-wrote the bootdelay timeout loop. However, it hard-coded the value that
get_delay()was expected to increment in one second, rather than calculating it based onCONFIG_SYS_HZ. On systems whereSYS_HZ!= 1000, this caused bootdelay timeout to be incorrect. Fix this.
Quoted 5 lines
Are there any such systems left? I agree with your patch, but if you know of systems that use incorrect values of
CONFIG_SYS_HZthen please point these out so they can be fixed!A system with
CONFIG_SYS_HZ!= 1000 is _broken_.
Then why does the config option still exist; surely it should be removed, or defined somewhere other than the per-board config file?
PATCH 1/1 Fix bootdelay timeout calculation when SYS_HZ!=1000
Dear Stephen Warren,
Quoted 3 lines · In message <[email protected]> you wrote:
Then why does the config option still exist; surely it should be removed, or defined somewhere other than the per-board config file?
Removing it requires work, including testing efforts...
Best regards,
Wolfgang Denk
Signature · 5 lines
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de A year spent in artificial intelligence is enough to make one believe in God.