PATCH 1/1 arm: dts: dra7: arch timer sits in always-on power domain

According to DRA7x TRM section 4.3.5 Realtime Counter (Master Counter), the realtime counter sits in the Wakeup Always-On Power domain. Furthermore, the counter will automatically switch the 32K clock source when MPU goes into standby and automatically switch back to SYS_CLK or ABE_LP when MPU goes out of standby.

---
 arch/arm/boot/dts/dra7.dtsi | 1 +
 1 file changed, 1 insertion(+)
arch/arm/boot/dts/dra7.dtsi +1 -0
index 8f1e25bcecbd..c1e6fd82485f 100644
@@ -50,6 +50,7 @@
 			     <GIC_PPI 11 (GIC_CPU_MASK_SIMPLE(2) | IRQ_TYPE_LEVEL_LOW)>,
 			     <GIC_PPI 10 (GIC_CPU_MASK_SIMPLE(2) | IRQ_TYPE_LEVEL_LOW)>;
 		interrupt-parent = <&gic>;
+		always-on;
 	};
 
 	gic: interrupt-controller at 48211000 {
Signature · 1 line
2.4.4
#1 lore raw

PATCH 1/1 arm: dts: dra7: arch timer sits in always-on power domain

Quoted 7 lines · Felipe Balbi

According to DRA7x TRM section 4.3.5 Realtime Counter (Master Counter), the realtime counter sits in the Wakeup Always-On Power domain. Furthermore, the counter will automatically switch the 32K clock source when MPU goes into standby and automatically switch back to SYS_CLK or ABE_LP when MPU goes out of standby.

Quoted 24 lines
---
 arch/arm/boot/dts/dra7.dtsi | 1 +
 1 file changed, 1 insertion(+)
arch/arm/boot/dts/dra7.dtsi +1 -1
index 8f1e25bcecbd..c1e6fd82485f 100644
@@ -50,6 +50,7 @@
                             <GIC_PPI 11 (GIC_CPU_MASK_SIMPLE(2) | IRQ_TYPE_LEVEL_LOW)>,
                             <GIC_PPI 10 (GIC_CPU_MASK_SIMPLE(2) | IRQ_TYPE_LEVEL_LOW)>;
                interrupt-parent = <&gic>;
+               always-on;
        };
 
        gic: interrupt-controller at 48211000 {
--

2.4.4

_______________________________________________
linux-arm-kernel mailing list
linux-arm-kernel at lists.infradead.org
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel

Signature · 3 lines
---
Regards,
Nishanth Menon
#2 lore raw

PATCH 1/1 arm: dts: dra7: arch timer sits in always-on power domain

Quoted 6 lines · Nishanth Menon
Quoted 5 lines · Felipe Balbi

According to DRA7x TRM section 4.3.5 Realtime Counter (Master Counter), the realtime counter sits in the Wakeup Always-On Power domain. Furthermore, the counter will automatically switch the 32K clock source when MPU goes into standby and automatically switch back to SYS_CLK or ABE_LP when MPU goes out of standby.

That's good to hear. Is that the case also for 5432?

Regards,

Tony

#3 lore raw

PATCH 1/1 arm: dts: dra7: arch timer sits in always-on power domain

Quoted 9 lines · Tony Lindgren
Quoted 6 lines · Nishanth Menon
Quoted 5 lines · Felipe Balbi

According to DRA7x TRM section 4.3.5 Realtime Counter (Master Counter), the realtime counter sits in the Wakeup Always-On Power domain. Furthermore, the counter will automatically switch the 32K clock source when MPU goes into standby and automatically switch back to SYS_CLK or ABE_LP when MPU goes out of standby.

That's good to hear. Is that the case also for 5432?

Adding into omap-for-v4.2/fixes, if 5432 supports it too it can be patched separately.

Regards,

Tony

#4 lore raw

PATCH 1/1 arm: dts: dra7: arch timer sits in always-on power domain

In reply to Felipe Balbi
Quoted 5 lines · Felipe Balbi

According to DRA7x TRM section 4.3.5 Realtime Counter (Master Counter), the realtime counter sits in the Wakeup Always-On Power domain. Furthermore, the counter will automatically switch the 32K clock source when MPU goes into standby and automatically switch back to SYS_CLK or ABE_LP when MPU goes out of standby.

While the counter is in an always-on domain (the architecture mandates this) I don't think that applies to the timers (i.e. the comparators within a CPU), which are almost certainly not in an always-on domain.

I suspect that this is incorrect, and it will be very painful to debug if it is...

Thanks,
Mark.

Quoted 27 lines
---
 arch/arm/boot/dts/dra7.dtsi | 1 +
 1 file changed, 1 insertion(+)
arch/arm/boot/dts/dra7.dtsi +1 -0
index 8f1e25bcecbd..c1e6fd82485f 100644
@@ -50,6 +50,7 @@
 			     <GIC_PPI 11 (GIC_CPU_MASK_SIMPLE(2) | IRQ_TYPE_LEVEL_LOW)>,
 			     <GIC_PPI 10 (GIC_CPU_MASK_SIMPLE(2) | IRQ_TYPE_LEVEL_LOW)>;
 		interrupt-parent = <&gic>;
+		always-on;
 	};
 
 	gic: interrupt-controller at 48211000 {
Signature · 7 lines
2.4.4


_______________________________________________
linux-arm-kernel mailing list
linux-arm-kernel at lists.infradead.org
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel
#5 lore raw

PATCH 1/1 arm: dts: dra7: arch timer sits in always-on power domain

Quoted 7 lines · Mark Rutland
Quoted 5 lines · Felipe Balbi

According to DRA7x TRM section 4.3.5 Realtime Counter (Master Counter), the realtime counter sits in the Wakeup Always-On Power domain. Furthermore, the counter will automatically switch the 32K clock source when MPU goes into standby and automatically switch back to SYS_CLK or ABE_LP when MPU goes out of standby.

Quoted 6 lines

While the counter is in an always-on domain (the architecture mandates this) I don't think that applies to the timers (i.e. the comparators within a CPU), which are almost certainly not in an always-on domain.

I suspect that this is incorrect, and it will be very painful to debug if it is...

OK good point. And there would have to be some wake-up line wired to the IO chain or the PMIC in this case if the comparator was always on.

Dropping this patch for now anyways.

Regards,

Tony