ARCH: imx: Call sata_remove() not on imx6 duallite/solo boards

PATCH New Ludwig Zenz 2 participants 2 messages Jul 2, 2019 – Jul 20, 2019

Subsystems (3)
lore
Share & tools
lore
#0 lore raw

PATCH 1/1 ARCH: imx: Call sata_remove() not on imx6 duallite/solo boards

For a single binary approach for imx6 quad/dual/duallite/solo it is necessary to enable CONFIG_SATA for quad/dual. On the other hand on imx6 duallite/sole SATA is not available.
Therefore sata_remove() is skipped according to a blacklist scheme.

Adding further imx derivates is probably not recessary as they are usually not pin-compatible and therefore a different board with its own configuration.

---
 arch/arm/mach-imx/cpu.c | 6 ++++--
 1 file changed, 4 insertions(+), 2 deletions(-)
arch/arm/mach-imx/cpu.c +4 -2
index d62ff6ef25..2559b8d89f 100644
@@ -289,10 +289,12 @@ void arch_preboot_os(void)
 	imx_pcie_remove();
 #endif
 #if defined(CONFIG_SATA)
-	sata_remove(0);
+	if (!is_mx6sdl()) {
+		sata_remove(0);
 #if defined(CONFIG_MX6)
-	disable_sata_clock();
+		disable_sata_clock();
 #endif
+	}
 #endif
 #if defined(CONFIG_VIDEO_IPUV3)
 	/* disable video before launching O/S */
Signature · 1 line
2.11.0
#1 lore raw

PATCH 1/1 ARCH: imx: Call sata_remove() not on imx6 duallite/solo boards

Quoted 8 lines

For a single binary approach for imx6 quad/dual/duallite/solo it is necessary to enable CONFIG_SATA for quad/dual. On the other hand on imx6 duallite/sole SATA is not available.
Therefore sata_remove() is skipped according to a blacklist scheme. Adding further imx derivates is probably not recessary as they are usually not pin-compatible and therefore a different board with its own configuration.

Applied to u-boot-imx, master, thanks !

Best regards,
Stefano Babic

Signature · 5 lines
=====================================================================
DENX Software Engineering GmbH,      Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sbabic at denx.de
=====================================================================