Skip to contentSkip to conversation

arm64: dts: qcom: sdm845: Fix DTS warnings

PATCH Superseded Vinod Koul 5 participants 16 messages Jul 22, 2019 – Jul 24, 2019

Subsystems (3)

v1 of 2 Superseded Latest is v2 →

lore
Share & tools
lore

Vinod Koul

author
#0 lore raw

cover arm64: dts: qcom: sdm845: Fix DTS warnings

So this is an attempt to fix some warns on sdm845 dts. We still have bunch of warnings to fix after this series (dupplicate adress and node names having underscores etc).

lets get long hanging ones fixed, we can see the warns with W=1 or W=2

Vinod Koul (5):
arm64: dts: qcom: sdm845: Add unit name to soc node
arm64: dts: qcom: sdm845: remove unnecessary properties for dsi nodes
arm64: dts: qcom: sdm845: remove unit name for thermal trip points
arm64: dts: qcom: sdm845: remove macro from unit name
arm64: dts: qcom: sdm845-cheza: remove macro from unit name

 arch/arm64/boot/dts/qcom/pm8998.dtsi       |  2 +-
 arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi | 10 ++--
 arch/arm64/boot/dts/qcom/sdm845.dtsi       | 66 ++++++++++------------
 3 files changed, 36 insertions(+), 42 deletions(-)

Thanks

Signature · 1 line
2.20.1
author
#1 lore raw

PATCH 1/5 arm64: dts: qcom: sdm845: Add unit name to soc node

We get a warning about missing unit name for soc node, so add it.

arch/arm64/boot/dts/qcom/sdm845.dtsi:623.11-2814.4: Warning (unit_address_vs_reg): /soc: node has a reg or ranges property, but no unit name

---
 arch/arm64/boot/dts/qcom/sdm845.dtsi | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
arch/arm64/boot/dts/qcom/sdm845.dtsi +1 -1
index 601cfb078bd5..e81f4a6d08ce 100644
@@ -620,7 +620,7 @@
 		method = "smc";
 	};
 
-	soc: soc {
+	soc: soc@0 {
 		#address-cells = <2>;
 		#size-cells = <2>;
 		ranges = <0 0 0 0 0x10 0>;
Signature · 1 line
2.20.1
Reviewed-by on v1 1/5
#2 lore raw

Re: [PATCH 1/5] arm64: dts: qcom: sdm845: Add unit name to soc node

Quoting Vinod Koul (2019-07-22 05:34:18)

Quoted 6 lines

We get a warning about missing unit name for soc node, so add it.

arch/arm64/boot/dts/qcom/sdm845.dtsi:623.11-2814.4: Warning (unit_address_vs_reg): /soc: node has a reg or ranges property, but no unit name

---

arch/arm64/boot/dts/qcom/sdm845.dtsi line 623

Quoted 10 lines
arch/arm64/boot/dts/qcom/sdm845.dtsi +1 -1
index 601cfb078bd5..e81f4a6d08ce 100644
@@ -620,7 +620,7 @@
                method = "smc";
        };
 
-       soc: soc {
+       soc: soc@0 {

This is kinda sad, but ok. Maybe you can apply this fix to at least all the qcom boards then.

Quoted 3 lines
arch/arm64/boot/dts/qcom/sdm845.dtsi +0 -0
                #address-cells = <2>;
                #size-cells = <2>;
                ranges = <0 0 0 0 0x10 0>;
author
#3 lore raw

Re: [PATCH 1/5] arm64: dts: qcom: sdm845: Add unit name to soc node

Quoted 9 lines · Stephen Boyd

Quoting Vinod Koul (2019-07-22 05:34:18)

Quoted 6 lines

We get a warning about missing unit name for soc node, so add it.

arch/arm64/boot/dts/qcom/sdm845.dtsi:623.11-2814.4: Warning (unit_address_vs_reg): /soc: node has a reg or ranges property, but no unit name

---

Thanks for the review

Quoted 9 lines
Quoted 9 lines
arch/arm64/boot/dts/qcom/sdm845.dtsi +0 -0
index 601cfb078bd5..e81f4a6d08ce 100644
@@ -620,7 +620,7 @@
                method = "smc";
        };
 
Quoted 5 lines

arch/arm64/boot/dts/qcom/sdm845.dtsi line 623

Quoted 2 lines
arch/arm64/boot/dts/qcom/sdm845.dtsi +1 -1
-       soc: soc {
+       soc: soc@0 {

This is kinda sad, but ok. Maybe you can apply this fix to at least all the qcom boards then.

Yeah that is the idea, start with sdm845 and 'reduce' the warns on all qcom dts files

Signature · 1 line
~Vinod
author
#4 lore raw

PATCH 2/5 arm64: dts: qcom: sdm845: remove unnecessary properties for dsi nodes

In reply to Vinod Koul

We get a warning about unnecessary properties of

arch/arm64/boot/dts/qcom/sdm845.dtsi:2211.22-2257.6: Warning (avoid_unnecessary_addr_size): /soc/mdss@ae00000/dsi@ae94000: unnecessary #address-cells/#size-cells without "ranges" or child "reg" property arch/arm64/boot/dts/qcom/sdm845.dtsi:2278.22-2324.6: Warning (avoid_unnecessary_addr_size): /soc/mdss@ae00000/dsi@ae96000: unnecessary #address-cells/#size-cells without "ranges" or child "reg" property

So, remove these properties

---
 arch/arm64/boot/dts/qcom/sdm845.dtsi | 6 ------
 1 file changed, 6 deletions(-)
arch/arm64/boot/dts/qcom/sdm845.dtsi +0 -6
index e81f4a6d08ce..2985df032179 100644
@@ -2234,9 +2234,6 @@
 
 				status = "disabled";
 
-				#address-cells = <1>;
-				#size-cells = <0>;
-
 				ports {
 					#address-cells = <1>;
 					#size-cells = <0>;
@@ -2301,9 +2298,6 @@
 
 				status = "disabled";
 
-				#address-cells = <1>;
-				#size-cells = <0>;
-
 				ports {
 					#address-cells = <1>;
 					#size-cells = <0>;
Signature · 1 line
2.20.1
Reviewed-by on v1 2/5
#5 lore raw

Re: [PATCH 2/5] arm64: dts: qcom: sdm845: remove unnecessary properties for dsi nodes

Quoting Vinod Koul (2019-07-22 05:34:19)

Quoted 9 lines

We get a warning about unnecessary properties of

arch/arm64/boot/dts/qcom/sdm845.dtsi:2211.22-2257.6: Warning (avoid_unnecessary_addr_size): /soc/mdss@ae00000/dsi@ae94000: unnecessary #address-cells/#size-cells without "ranges" or child "reg" property arch/arm64/boot/dts/qcom/sdm845.dtsi:2278.22-2324.6: Warning (avoid_unnecessary_addr_size): /soc/mdss@ae00000/dsi@ae96000: unnecessary #address-cells/#size-cells without "ranges" or child "reg" property

So, remove these properties

---

author
#6 lore raw

PATCH 3/5 arm64: dts: qcom: sdm845: remove unit name for thermal trip points

In reply to Vinod Koul

The thermal trip points have unit name but no reg property, so we can remove them

arch/arm64/boot/dts/qcom/sdm845.dtsi:2824.31-2828.7: Warning (unit_address_vs_reg): /thermal-zones/cpu0-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2830.31-2834.7: Warning (unit_address_vs_reg): /thermal-zones/cpu0-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2868.31-2872.7: Warning (unit_address_vs_reg): /thermal-zones/cpu1-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2874.31-2878.7: Warning (unit_address_vs_reg): /thermal-zones/cpu1-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2912.31-2916.7: Warning (unit_address_vs_reg): /thermal-zones/cpu2-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2918.31-2922.7: Warning (unit_address_vs_reg): /thermal-zones/cpu2-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2956.31-2960.7: Warning (unit_address_vs_reg): /thermal-zones/cpu3-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2962.31-2966.7: Warning (unit_address_vs_reg): /thermal-zones/cpu3-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3000.31-3004.7: Warning (unit_address_vs_reg): /thermal-zones/cpu4-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3006.31-3010.7: Warning (unit_address_vs_reg): /thermal-zones/cpu4-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3044.31-3048.7: Warning (unit_address_vs_reg): /thermal-zones/cpu5-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3050.31-3054.7: Warning (unit_address_vs_reg): /thermal-zones/cpu5-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3088.31-3092.7: Warning (unit_address_vs_reg): /thermal-zones/cpu6-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3094.31-3098.7: Warning (unit_address_vs_reg): /thermal-zones/cpu6-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3132.31-3136.7: Warning (unit_address_vs_reg): /thermal-zones/cpu7-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3138.31-3142.7: Warning (unit_address_vs_reg): /thermal-zones/cpu7-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3176.32-3180.7: Warning (unit_address_vs_reg): /thermal-zones/aoss0-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3191.35-3195.7: Warning (unit_address_vs_reg): /thermal-zones/cluster0-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3211.35-3215.7: Warning (unit_address_vs_reg): /thermal-zones/cluster1-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3231.31-3235.7: Warning (unit_address_vs_reg): /thermal-zones/gpu-thermal-top/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3246.31-3250.7: Warning (unit_address_vs_reg): /thermal-zones/gpu-thermal-bottom/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3261.32-3265.7: Warning (unit_address_vs_reg): /thermal-zones/aoss1-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3276.35-3280.7: Warning (unit_address_vs_reg): /thermal-zones/q6-modem-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3291.30-3295.7: Warning (unit_address_vs_reg): /thermal-zones/mem-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3306.31-3310.7: Warning (unit_address_vs_reg): /thermal-zones/wlan-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3321.33-3325.7: Warning (unit_address_vs_reg): /thermal-zones/q6-hvx-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3336.33-3340.7: Warning (unit_address_vs_reg): /thermal-zones/camera-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3351.32-3355.7: Warning (unit_address_vs_reg): /thermal-zones/video-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3366.32-3370.7: Warning (unit_address_vs_reg): /thermal-zones/modem-thermal/trips/trip-point@0: node has a unit name, but no reg property

---
 arch/arm64/boot/dts/qcom/sdm845.dtsi | 58 ++++++++++++++--------------
 1 file changed, 29 insertions(+), 29 deletions(-)
arch/arm64/boot/dts/qcom/sdm845.dtsi +29 -29
index 2985df032179..48bd07646eb4 100644
@@ -2815,13 +2815,13 @@
 			thermal-sensors = <&tsens0 1>;
 
 			trips {
-				cpu0_alert0: trip-point@0 {
+				cpu0_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "passive";
 				};
 
-				cpu0_alert1: trip-point@1 {
+				cpu0_alert1: trip-point1 {
 					temperature = <95000>;
 					hysteresis = <2000>;
 					type = "passive";
@@ -2859,13 +2859,13 @@
 			thermal-sensors = <&tsens0 2>;
 
 			trips {
-				cpu1_alert0: trip-point@0 {
+				cpu1_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "passive";
 				};
 
-				cpu1_alert1: trip-point@1 {
+				cpu1_alert1: trip-point1 {
 					temperature = <95000>;
 					hysteresis = <2000>;
 					type = "passive";
@@ -2903,13 +2903,13 @@
 			thermal-sensors = <&tsens0 3>;
 
 			trips {
-				cpu2_alert0: trip-point@0 {
+				cpu2_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "passive";
 				};
 
-				cpu2_alert1: trip-point@1 {
+				cpu2_alert1: trip-point1 {
 					temperature = <95000>;
 					hysteresis = <2000>;
 					type = "passive";
@@ -2947,13 +2947,13 @@
 			thermal-sensors = <&tsens0 4>;
 
 			trips {
-				cpu3_alert0: trip-point@0 {
+				cpu3_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "passive";
 				};
 
-				cpu3_alert1: trip-point@1 {
+				cpu3_alert1: trip-point1 {
 					temperature = <95000>;
 					hysteresis = <2000>;
 					type = "passive";
@@ -2991,13 +2991,13 @@
 			thermal-sensors = <&tsens0 7>;
 
 			trips {
-				cpu4_alert0: trip-point@0 {
+				cpu4_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "passive";
 				};
 
-				cpu4_alert1: trip-point@1 {
+				cpu4_alert1: trip-point1 {
 					temperature = <95000>;
 					hysteresis = <2000>;
 					type = "passive";
@@ -3035,13 +3035,13 @@
 			thermal-sensors = <&tsens0 8>;
 
 			trips {
-				cpu5_alert0: trip-point@0 {
+				cpu5_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "passive";
 				};
 
-				cpu5_alert1: trip-point@1 {
+				cpu5_alert1: trip-point1 {
 					temperature = <95000>;
 					hysteresis = <2000>;
 					type = "passive";
@@ -3079,13 +3079,13 @@
 			thermal-sensors = <&tsens0 9>;
 
 			trips {
-				cpu6_alert0: trip-point@0 {
+				cpu6_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "passive";
 				};
 
-				cpu6_alert1: trip-point@1 {
+				cpu6_alert1: trip-point1 {
 					temperature = <95000>;
 					hysteresis = <2000>;
 					type = "passive";
@@ -3123,13 +3123,13 @@
 			thermal-sensors = <&tsens0 10>;
 
 			trips {
-				cpu7_alert0: trip-point@0 {
+				cpu7_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "passive";
 				};
 
-				cpu7_alert1: trip-point@1 {
+				cpu7_alert1: trip-point1 {
 					temperature = <95000>;
 					hysteresis = <2000>;
 					type = "passive";
@@ -3167,7 +3167,7 @@
 			thermal-sensors = <&tsens0 0>;
 
 			trips {
-				aoss0_alert0: trip-point@0 {
+				aoss0_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "hot";
@@ -3182,7 +3182,7 @@
 			thermal-sensors = <&tsens0 5>;
 
 			trips {
-				cluster0_alert0: trip-point@0 {
+				cluster0_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "hot";
@@ -3202,7 +3202,7 @@
 			thermal-sensors = <&tsens0 6>;
 
 			trips {
-				cluster1_alert0: trip-point@0 {
+				cluster1_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "hot";
@@ -3222,7 +3222,7 @@
 			thermal-sensors = <&tsens0 11>;
 
 			trips {
-				gpu1_alert0: trip-point@0 {
+				gpu1_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "hot";
@@ -3237,7 +3237,7 @@
 			thermal-sensors = <&tsens0 12>;
 
 			trips {
-				gpu2_alert0: trip-point@0 {
+				gpu2_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "hot";
@@ -3252,7 +3252,7 @@
 			thermal-sensors = <&tsens1 0>;
 
 			trips {
-				aoss1_alert0: trip-point@0 {
+				aoss1_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "hot";
@@ -3267,7 +3267,7 @@
 			thermal-sensors = <&tsens1 1>;
 
 			trips {
-				q6_modem_alert0: trip-point@0 {
+				q6_modem_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "hot";
@@ -3282,7 +3282,7 @@
 			thermal-sensors = <&tsens1 2>;
 
 			trips {
-				mem_alert0: trip-point@0 {
+				mem_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "hot";
@@ -3297,7 +3297,7 @@
 			thermal-sensors = <&tsens1 3>;
 
 			trips {
-				wlan_alert0: trip-point@0 {
+				wlan_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "hot";
@@ -3312,7 +3312,7 @@
 			thermal-sensors = <&tsens1 4>;
 
 			trips {
-				q6_hvx_alert0: trip-point@0 {
+				q6_hvx_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "hot";
@@ -3327,7 +3327,7 @@
 			thermal-sensors = <&tsens1 5>;
 
 			trips {
-				camera_alert0: trip-point@0 {
+				camera_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "hot";
@@ -3342,7 +3342,7 @@
 			thermal-sensors = <&tsens1 6>;
 
 			trips {
-				video_alert0: trip-point@0 {
+				video_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "hot";
@@ -3357,7 +3357,7 @@
 			thermal-sensors = <&tsens1 7>;
 
 			trips {
-				modem_alert0: trip-point@0 {
+				modem_alert0: trip-point0 {
 					temperature = <90000>;
 					hysteresis = <2000>;
 					type = "hot";
Signature · 1 line
2.20.1
Reviewed-by on v1 3/5
#7 lore raw

Re: [PATCH 3/5] arm64: dts: qcom: sdm845: remove unit name for thermal trip points

Quoting Vinod Koul (2019-07-22 05:34:20)

Quoted 33 lines

The thermal trip points have unit name but no reg property, so we can remove them

arch/arm64/boot/dts/qcom/sdm845.dtsi:2824.31-2828.7: Warning (unit_address_vs_reg): /thermal-zones/cpu0-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2830.31-2834.7: Warning (unit_address_vs_reg): /thermal-zones/cpu0-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2868.31-2872.7: Warning (unit_address_vs_reg): /thermal-zones/cpu1-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2874.31-2878.7: Warning (unit_address_vs_reg): /thermal-zones/cpu1-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2912.31-2916.7: Warning (unit_address_vs_reg): /thermal-zones/cpu2-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2918.31-2922.7: Warning (unit_address_vs_reg): /thermal-zones/cpu2-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2956.31-2960.7: Warning (unit_address_vs_reg): /thermal-zones/cpu3-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2962.31-2966.7: Warning (unit_address_vs_reg): /thermal-zones/cpu3-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3000.31-3004.7: Warning (unit_address_vs_reg): /thermal-zones/cpu4-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3006.31-3010.7: Warning (unit_address_vs_reg): /thermal-zones/cpu4-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3044.31-3048.7: Warning (unit_address_vs_reg): /thermal-zones/cpu5-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3050.31-3054.7: Warning (unit_address_vs_reg): /thermal-zones/cpu5-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3088.31-3092.7: Warning (unit_address_vs_reg): /thermal-zones/cpu6-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3094.31-3098.7: Warning (unit_address_vs_reg): /thermal-zones/cpu6-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3132.31-3136.7: Warning (unit_address_vs_reg): /thermal-zones/cpu7-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3138.31-3142.7: Warning (unit_address_vs_reg): /thermal-zones/cpu7-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3176.32-3180.7: Warning (unit_address_vs_reg): /thermal-zones/aoss0-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3191.35-3195.7: Warning (unit_address_vs_reg): /thermal-zones/cluster0-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3211.35-3215.7: Warning (unit_address_vs_reg): /thermal-zones/cluster1-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3231.31-3235.7: Warning (unit_address_vs_reg): /thermal-zones/gpu-thermal-top/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3246.31-3250.7: Warning (unit_address_vs_reg): /thermal-zones/gpu-thermal-bottom/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3261.32-3265.7: Warning (unit_address_vs_reg): /thermal-zones/aoss1-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3276.35-3280.7: Warning (unit_address_vs_reg): /thermal-zones/q6-modem-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3291.30-3295.7: Warning (unit_address_vs_reg): /thermal-zones/mem-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3306.31-3310.7: Warning (unit_address_vs_reg): /thermal-zones/wlan-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3321.33-3325.7: Warning (unit_address_vs_reg): /thermal-zones/q6-hvx-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3336.33-3340.7: Warning (unit_address_vs_reg): /thermal-zones/camera-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3351.32-3355.7: Warning (unit_address_vs_reg): /thermal-zones/video-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3366.32-3370.7: Warning (unit_address_vs_reg): /thermal-zones/modem-thermal/trips/trip-point@0: node has a unit name, but no reg property

Quoted 2 lines

---

author
#8 lore raw

PATCH 4/5 arm64: dts: qcom: sdm845: remove macro from unit name

In reply to Vinod Koul

Unit name is supposed to be a number, using a macro with hex value is not recommended, so add the value in unit name.

arch/arm64/boot/dts/qcom/pm8998.dtsi:81.18-84.6: Warning (unit_address_format): /soc/spmi@c440000/pmic@0/adc@3100/adc-chan@0x06: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/pm8998.dtsi:81.18-84.6: Warning (unit_address_format): /soc/spmi@c440000/pmic@0/adc@3100/adc-chan@0x06: unit name should not have leading 0s

---
 arch/arm64/boot/dts/qcom/pm8998.dtsi | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
arch/arm64/boot/dts/qcom/pm8998.dtsi +1 -1
index 051a52df80f9..d76c8377c224 100644
@@ -78,7 +78,7 @@
 			#size-cells = <0>;
 			#io-channel-cells = <1>;
 
-			adc-chan@ADC5_DIE_TEMP {
+			adc-chan@6{
 				reg = <ADC5_DIE_TEMP>;
 				label = "die_temp";
 			};
Signature · 1 line
2.20.1
#9 lore raw

Re: [PATCH 4/5] arm64: dts: qcom: sdm845: remove macro from unit name

Quoted 16 lines · Vinod Koul

Unit name is supposed to be a number, using a macro with hex value is not recommended, so add the value in unit name.

arch/arm64/boot/dts/qcom/pm8998.dtsi:81.18-84.6: Warning (unit_address_format): /soc/spmi@c440000/pmic@0/adc@3100/adc-chan@0x06: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/pm8998.dtsi:81.18-84.6: Warning (unit_address_format): /soc/spmi@c440000/pmic@0/adc@3100/adc-chan@0x06: unit name should not have leading 0s

---
 arch/arm64/boot/dts/qcom/pm8998.dtsi | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
arch/arm64/boot/dts/qcom/pm8998.dtsi +0 -0
index 051a52df80f9..d76c8377c224 100644

arch/arm64/boot/dts/qcom/pm8998.dtsi line 81

Quoted 5 lines
arch/arm64/boot/dts/qcom/pm8998.dtsi +1 -1
@@ -78,7 +78,7 @@
 			#size-cells = <0>;
 			#io-channel-cells = <1>;
 
-			adc-chan@ADC5_DIE_TEMP {
+			adc-chan@6{

You dropped the space before the {

;-)

author
#10 lore raw

Re: [PATCH 4/5] arm64: dts: qcom: sdm845: remove macro from unit name

Quoted 21 lines · Marc Gonzalez
Quoted 19 lines · Vinod Koul

Unit name is supposed to be a number, using a macro with hex value is not recommended, so add the value in unit name.

arch/arm64/boot/dts/qcom/pm8998.dtsi:81.18-84.6: Warning (unit_address_format): /soc/spmi@c440000/pmic@0/adc@3100/adc-chan@0x06: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/pm8998.dtsi:81.18-84.6: Warning (unit_address_format): /soc/spmi@c440000/pmic@0/adc@3100/adc-chan@0x06: unit name should not have leading 0s

---
 arch/arm64/boot/dts/qcom/pm8998.dtsi | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
arch/arm64/boot/dts/qcom/pm8998.dtsi +0 -0
index 051a52df80f9..d76c8377c224 100644
@@ -78,7 +78,7 @@
 			#size-cells = <0>;
 			#io-channel-cells = <1>;
 
Quoted 4 lines

arch/arm64/boot/dts/qcom/pm8998.dtsi line 81

Quoted 2 lines
arch/arm64/boot/dts/qcom/pm8998.dtsi +1 -1
-			adc-chan@ADC5_DIE_TEMP {
+			adc-chan@6{

You dropped the space before the {

Oops, will fix it up, thanks for pointing!

Signature · 1 line
~Vinod
author
#11 lore raw

PATCH 5/5 arm64: dts: qcom: sdm845-cheza: remove macro from unit name

In reply to Vinod Koul

Unit name is supposed to be a number, using a macro with hex value is not recommended, so add the value in unit name.

arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:966.16-969.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4d: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:971.16-974.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4e: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:976.16-979.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4f: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:981.16-984.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x50: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:986.16-989.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x51: unit name should not have leading "0x"

---
 arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi | 10 +++++-----
 1 file changed, 5 insertions(+), 5 deletions(-)
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi +5 -5
index 1ebbd568dfd7..9b27b8346ba1 100644
@@ -963,27 +963,27 @@ ap_ts_i2c: &i2c14 {
 };
 
 &pm8998_adc {
-	adc-chan@ADC5_AMUX_THM1_100K_PU {
+	adc-chan@4d {
 		reg = <ADC5_AMUX_THM1_100K_PU>;
 		label = "sdm_temp";
 	};
 
-	adc-chan@ADC5_AMUX_THM2_100K_PU {
+	adc-chan@4e {
 		reg = <ADC5_AMUX_THM2_100K_PU>;
 		label = "quiet_temp";
 	};
 
-	adc-chan@ADC5_AMUX_THM3_100K_PU {
+	adc-chan@4f {
 		reg = <ADC5_AMUX_THM3_100K_PU>;
 		label = "lte_temp_1";
 	};
 
-	adc-chan@ADC5_AMUX_THM4_100K_PU {
+	adc-chan@50 {
 		reg = <ADC5_AMUX_THM4_100K_PU>;
 		label = "lte_temp_2";
 	};
 
-	adc-chan@ADC5_AMUX_THM5_100K_PU {
+	adc-chan@51 {
 		reg = <ADC5_AMUX_THM5_100K_PU>;
 		label = "charger_temp";
 	};
Signature · 1 line
2.20.1
#12 lore raw

Re: [PATCH 5/5] arm64: dts: qcom: sdm845-cheza: remove macro from unit name

Quoted 2 lines · Vinod Koul

Unit name is supposed to be a number, using a macro with hex value is

/s/name/address?

Quoted 18 lines

not recommended, so add the value in unit name.

arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:966.16-969.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4d: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:971.16-974.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4e: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:976.16-979.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4f: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:981.16-984.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x50: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:986.16-989.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x51: unit name should not have leading "0x"

---
 arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi | 10 +++++-----
 1 file changed, 5 insertions(+), 5 deletions(-)
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi +0 -0
index 1ebbd568dfd7..9b27b8346ba1 100644

arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi ap_ts_i2c: &i2c14 { · line 967

Quoted 6 lines
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi +1 -1
@@ -963,27 +963,27 @@ ap_ts_i2c: &i2c14 {
 };
 
 &pm8998_adc {
-       adc-chan@ADC5_AMUX_THM1_100K_PU {
+       adc-chan@4d {
                reg = <ADC5_AMUX_THM1_100K_PU>;

I'm a little conflicted about this change. If we're replacing the address with actual values, perhaps we should do that same for the reg property to keep them in sync? Admittedly though, it is a bit easier to read the macro name and figure out its meaning.

Quoted 29 lines
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi +4 -5
                label = "sdm_temp";
        };
 
-       adc-chan@ADC5_AMUX_THM2_100K_PU {
+       adc-chan@4e {
                reg = <ADC5_AMUX_THM2_100K_PU>;
                label = "quiet_temp";
        };
 
-       adc-chan@ADC5_AMUX_THM3_100K_PU {
+       adc-chan@4f {
                reg = <ADC5_AMUX_THM3_100K_PU>;
                label = "lte_temp_1";
        };
 
-       adc-chan@ADC5_AMUX_THM4_100K_PU {
+       adc-chan@50 {
                reg = <ADC5_AMUX_THM4_100K_PU>;
                label = "lte_temp_2";
        };
 
-       adc-chan@ADC5_AMUX_THM5_100K_PU {
+       adc-chan@51 {
                reg = <ADC5_AMUX_THM5_100K_PU>;
                label = "charger_temp";
        };
--

2.20.1

author
#13 lore raw

Re: [PATCH 5/5] arm64: dts: qcom: sdm845-cheza: remove macro from unit name

Quoted 5 lines · Amit Kucheria
Quoted 2 lines · Vinod Koul

Unit name is supposed to be a number, using a macro with hex value is

/s/name/address?

Right, will fix.

Quoted 20 lines
Quoted 20 lines

not recommended, so add the value in unit name.

arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:966.16-969.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4d: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:971.16-974.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4e: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:976.16-979.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4f: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:981.16-984.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x50: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:986.16-989.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x51: unit name should not have leading "0x"

---
 arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi | 10 +++++-----
 1 file changed, 5 insertions(+), 5 deletions(-)
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi +0 -0
index 1ebbd568dfd7..9b27b8346ba1 100644
@@ -963,27 +963,27 @@ ap_ts_i2c: &i2c14 {
 };
 
Quoted 9 lines

arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi ap_ts_i2c: &i2c14 { · line 967

Quoted 4 lines
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi +1 -1
 &pm8998_adc {
-       adc-chan@ADC5_AMUX_THM1_100K_PU {
+       adc-chan@4d {
                reg = <ADC5_AMUX_THM1_100K_PU>;

I'm a little conflicted about this change. If we're replacing the address with actual values, perhaps we should do that same for the reg property to keep them in sync? Admittedly though, it is a bit easier to read the macro name and figure out its meaning.

Well this was how Bjorn suggested, am okay if we do in any other way. This fixes warning but keeps it bit readable too

Other way would be to make defines decimal values instead of hex

Any better suggestions :)

Signature · 1 line
~Vinod
#14 lore raw

Re: [PATCH 5/5] arm64: dts: qcom: sdm845-cheza: remove macro from unit name

Quoted 29 lines · Vinod Koul
Quoted 5 lines · Amit Kucheria
Quoted 2 lines · Vinod Koul

Unit name is supposed to be a number, using a macro with hex value is

/s/name/address?

Right, will fix.

Quoted 20 lines
Quoted 20 lines

not recommended, so add the value in unit name.

arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:966.16-969.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4d: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:971.16-974.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4e: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:976.16-979.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4f: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:981.16-984.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x50: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:986.16-989.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x51: unit name should not have leading "0x"

---
 arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi | 10 +++++-----
 1 file changed, 5 insertions(+), 5 deletions(-)
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi +0 -0
index 1ebbd568dfd7..9b27b8346ba1 100644
@@ -963,27 +963,27 @@ ap_ts_i2c: &i2c14 {
 };
 
Quoted 4 lines
Quoted 4 lines

arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi ap_ts_i2c: &i2c14 { · line 967

Quoted 4 lines
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi +1 -1
 &pm8998_adc {
-       adc-chan@ADC5_AMUX_THM1_100K_PU {
+       adc-chan@4d {
                reg = <ADC5_AMUX_THM1_100K_PU>;

When I read this define I instantly know which channel we're referring to. The 4d above is simply there for syntactical purposes and needs only to be cared about if the reg is ever changed.

So I like this form.

Quoted 11 lines
Quoted 5 lines

I'm a little conflicted about this change. If we're replacing the address with actual values, perhaps we should do that same for the reg property to keep them in sync? Admittedly though, it is a bit easier to read the macro name and figure out its meaning.

Well this was how Bjorn suggested, am okay if we do in any other way. This fixes warning but keeps it bit readable too

Other way would be to make defines decimal values instead of hex

While the ePAPRR states that the unit address must match the first reg, dtc enforces that the unit address string matches "%x" of the reg.

Regards,
Bjorn

Quoted 4 lines

Any better suggestions :)

Signature · 1 line
~Vinod
Reviewed-by on v1 5/5
#15 lore raw

Re: [PATCH 5/5] arm64: dts: qcom: sdm845-cheza: remove macro from unit name

In reply to Vinod Koul

Quoting Vinod Koul (2019-07-22 05:34:22)

Quoted 11 lines

Unit name is supposed to be a number, using a macro with hex value is not recommended, so add the value in unit name.

arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:966.16-969.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4d: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:971.16-974.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4e: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:976.16-979.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4f: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:981.16-984.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x50: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:986.16-989.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x51: unit name should not have leading "0x"

---