arm64: dts: qcom: sdm845: Fix DTS warnings
cover arm64: dts: qcom: sdm845: Fix DTS warnings
So this is an attempt to fix some warns on sdm845 dts. We still have bunch of warnings to fix after this series (dupplicate adress and node names having underscores etc).
lets get long hanging ones fixed, we can see the warns with W=1 or W=2
Vinod Koul (5):
arm64: dts: qcom: sdm845: Add unit name to soc node
arm64: dts: qcom: sdm845: remove unnecessary properties for dsi nodes
arm64: dts: qcom: sdm845: remove unit name for thermal trip points
arm64: dts: qcom: sdm845: remove macro from unit name
arm64: dts: qcom: sdm845-cheza: remove macro from unit name
arch/arm64/boot/dts/qcom/pm8998.dtsi | 2 +- arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi | 10 ++-- arch/arm64/boot/dts/qcom/sdm845.dtsi | 66 ++++++++++------------ 3 files changed, 36 insertions(+), 42 deletions(-)
Thanks
Signature · 1 line
2.20.1
PATCH 1/5 arm64: dts: qcom: sdm845: Add unit name to soc node
We get a warning about missing unit name for soc node, so add it.
arch/arm64/boot/dts/qcom/sdm845.dtsi:623.11-2814.4: Warning (unit_address_vs_reg): /soc: node has a reg or ranges property, but no unit name
--- arch/arm64/boot/dts/qcom/sdm845.dtsi | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
arch/arm64/boot/dts/qcom/sdm845.dtsi +1 -1
@@ -620,7 +620,7 @@ method = "smc"; }; - soc: soc { + soc: soc@0 { #address-cells = <2>; #size-cells = <2>; ranges = <0 0 0 0 0x10 0>;
Signature · 1 line
2.20.1
Re: [PATCH 1/5] arm64: dts: qcom: sdm845: Add unit name to soc node
Quoting Vinod Koul (2019-07-22 05:34:18)
Quoted 6 lines
We get a warning about missing unit name for soc node, so add it.
arch/arm64/boot/dts/qcom/sdm845.dtsi:623.11-2814.4: Warning (
unit_address_vs_reg): /soc: node has a reg or ranges property, but no unit nameSigned-off-by Vinod Koul <[email protected]>---
arch/arm64/boot/dts/qcom/sdm845.dtsi line 623
Quoted 10 lines
arch/arm64/boot/dts/qcom/sdm845.dtsi +1
-1@@ -620,7 +620,7 @@ method = "smc"; }; - soc: soc { + soc: soc@0 {
This is kinda sad, but ok. Maybe you can apply this fix to at least all the qcom boards then.
Quoted 3 lines
arch/arm64/boot/dts/qcom/sdm845.dtsi +0
-0#address-cells = <2>; #size-cells = <2>; ranges = <0 0 0 0 0x10 0>;
Re: [PATCH 1/5] arm64: dts: qcom: sdm845: Add unit name to soc node
Quoted 9 lines · Stephen Boyd
Quoting Vinod Koul (2019-07-22 05:34:18)
Quoted 6 lines
We get a warning about missing unit name for soc node, so add it.
arch/arm64/boot/dts/qcom/sdm845.dtsi:623.11-2814.4: Warning (
unit_address_vs_reg): /soc: node has a reg or ranges property, but no unit nameSigned-off-by Vinod Koul <[email protected]>---
Reviewed-by Stephen Boyd <[email protected]>
Thanks for the review
Quoted 9 lines
Quoted 9 lines
arch/arm64/boot/dts/qcom/sdm845.dtsi +0
-0@@ -620,7 +620,7 @@ method = "smc"; };
Quoted 5 lines
arch/arm64/boot/dts/qcom/sdm845.dtsi line 623
Quoted 2 lines
arch/arm64/boot/dts/qcom/sdm845.dtsi +1
-1- soc: soc { + soc: soc@0 {This is kinda sad, but ok. Maybe you can apply this fix to at least all the qcom boards then.
Yeah that is the idea, start with sdm845 and 'reduce' the warns on all qcom dts files
Signature · 1 line
~Vinod
PATCH 2/5 arm64: dts: qcom: sdm845: remove unnecessary properties for dsi nodes
In reply to Vinod KoulWe get a warning about unnecessary properties of
arch/arm64/boot/dts/qcom/sdm845.dtsi:2211.22-2257.6: Warning (avoid_unnecessary_addr_size): /soc/mdss@ae00000/dsi@ae94000: unnecessary #address-cells/#size-cells without "ranges" or child "reg" property arch/arm64/boot/dts/qcom/sdm845.dtsi:2278.22-2324.6: Warning (avoid_unnecessary_addr_size): /soc/mdss@ae00000/dsi@ae96000: unnecessary #address-cells/#size-cells without "ranges" or child "reg" property
So, remove these properties
--- arch/arm64/boot/dts/qcom/sdm845.dtsi | 6 ------ 1 file changed, 6 deletions(-)
arch/arm64/boot/dts/qcom/sdm845.dtsi +0 -6
@@ -2234,9 +2234,6 @@ status = "disabled"; - #address-cells = <1>; - #size-cells = <0>; - ports { #address-cells = <1>; #size-cells = <0>;
@@ -2301,9 +2298,6 @@ status = "disabled"; - #address-cells = <1>; - #size-cells = <0>; - ports { #address-cells = <1>; #size-cells = <0>;
Signature · 1 line
2.20.1
Re: [PATCH 2/5] arm64: dts: qcom: sdm845: remove unnecessary properties for dsi nodes
Quoting Vinod Koul (2019-07-22 05:34:19)
Quoted 9 lines
We get a warning about unnecessary properties of
arch/arm64/boot/dts/qcom/sdm845.dtsi:2211.22-2257.6: Warning (
avoid_unnecessary_addr_size): /soc/mdss@ae00000/dsi@ae94000: unnecessary #address-cells/#size-cells without "ranges" or child "reg" property arch/arm64/boot/dts/qcom/sdm845.dtsi:2278.22-2324.6: Warning (avoid_unnecessary_addr_size): /soc/mdss@ae00000/dsi@ae96000: unnecessary #address-cells/#size-cells without "ranges" or child "reg" propertySo, remove these properties
Signed-off-by Vinod Koul <[email protected]>---
PATCH 3/5 arm64: dts: qcom: sdm845: remove unit name for thermal trip points
In reply to Vinod KoulThe thermal trip points have unit name but no reg property, so we can remove them
arch/arm64/boot/dts/qcom/sdm845.dtsi:2824.31-2828.7: Warning (unit_address_vs_reg): /thermal-zones/cpu0-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2830.31-2834.7: Warning (unit_address_vs_reg): /thermal-zones/cpu0-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2868.31-2872.7: Warning (unit_address_vs_reg): /thermal-zones/cpu1-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2874.31-2878.7: Warning (unit_address_vs_reg): /thermal-zones/cpu1-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2912.31-2916.7: Warning (unit_address_vs_reg): /thermal-zones/cpu2-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2918.31-2922.7: Warning (unit_address_vs_reg): /thermal-zones/cpu2-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2956.31-2960.7: Warning (unit_address_vs_reg): /thermal-zones/cpu3-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2962.31-2966.7: Warning (unit_address_vs_reg): /thermal-zones/cpu3-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3000.31-3004.7: Warning (unit_address_vs_reg): /thermal-zones/cpu4-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3006.31-3010.7: Warning (unit_address_vs_reg): /thermal-zones/cpu4-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3044.31-3048.7: Warning (unit_address_vs_reg): /thermal-zones/cpu5-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3050.31-3054.7: Warning (unit_address_vs_reg): /thermal-zones/cpu5-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3088.31-3092.7: Warning (unit_address_vs_reg): /thermal-zones/cpu6-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3094.31-3098.7: Warning (unit_address_vs_reg): /thermal-zones/cpu6-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3132.31-3136.7: Warning (unit_address_vs_reg): /thermal-zones/cpu7-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3138.31-3142.7: Warning (unit_address_vs_reg): /thermal-zones/cpu7-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3176.32-3180.7: Warning (unit_address_vs_reg): /thermal-zones/aoss0-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3191.35-3195.7: Warning (unit_address_vs_reg): /thermal-zones/cluster0-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3211.35-3215.7: Warning (unit_address_vs_reg): /thermal-zones/cluster1-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3231.31-3235.7: Warning (unit_address_vs_reg): /thermal-zones/gpu-thermal-top/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3246.31-3250.7: Warning (unit_address_vs_reg): /thermal-zones/gpu-thermal-bottom/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3261.32-3265.7: Warning (unit_address_vs_reg): /thermal-zones/aoss1-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3276.35-3280.7: Warning (unit_address_vs_reg): /thermal-zones/q6-modem-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3291.30-3295.7: Warning (unit_address_vs_reg): /thermal-zones/mem-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3306.31-3310.7: Warning (unit_address_vs_reg): /thermal-zones/wlan-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3321.33-3325.7: Warning (unit_address_vs_reg): /thermal-zones/q6-hvx-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3336.33-3340.7: Warning (unit_address_vs_reg): /thermal-zones/camera-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3351.32-3355.7: Warning (unit_address_vs_reg): /thermal-zones/video-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3366.32-3370.7: Warning (unit_address_vs_reg): /thermal-zones/modem-thermal/trips/trip-point@0: node has a unit name, but no reg property
--- arch/arm64/boot/dts/qcom/sdm845.dtsi | 58 ++++++++++++++-------------- 1 file changed, 29 insertions(+), 29 deletions(-)
arch/arm64/boot/dts/qcom/sdm845.dtsi +29 -29
@@ -2815,13 +2815,13 @@ thermal-sensors = <&tsens0 1>; trips { - cpu0_alert0: trip-point@0 { + cpu0_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "passive"; }; - cpu0_alert1: trip-point@1 { + cpu0_alert1: trip-point1 { temperature = <95000>; hysteresis = <2000>; type = "passive";
@@ -2859,13 +2859,13 @@ thermal-sensors = <&tsens0 2>; trips { - cpu1_alert0: trip-point@0 { + cpu1_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "passive"; }; - cpu1_alert1: trip-point@1 { + cpu1_alert1: trip-point1 { temperature = <95000>; hysteresis = <2000>; type = "passive";
@@ -2903,13 +2903,13 @@ thermal-sensors = <&tsens0 3>; trips { - cpu2_alert0: trip-point@0 { + cpu2_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "passive"; }; - cpu2_alert1: trip-point@1 { + cpu2_alert1: trip-point1 { temperature = <95000>; hysteresis = <2000>; type = "passive";
@@ -2947,13 +2947,13 @@ thermal-sensors = <&tsens0 4>; trips { - cpu3_alert0: trip-point@0 { + cpu3_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "passive"; }; - cpu3_alert1: trip-point@1 { + cpu3_alert1: trip-point1 { temperature = <95000>; hysteresis = <2000>; type = "passive";
@@ -2991,13 +2991,13 @@ thermal-sensors = <&tsens0 7>; trips { - cpu4_alert0: trip-point@0 { + cpu4_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "passive"; }; - cpu4_alert1: trip-point@1 { + cpu4_alert1: trip-point1 { temperature = <95000>; hysteresis = <2000>; type = "passive";
@@ -3035,13 +3035,13 @@ thermal-sensors = <&tsens0 8>; trips { - cpu5_alert0: trip-point@0 { + cpu5_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "passive"; }; - cpu5_alert1: trip-point@1 { + cpu5_alert1: trip-point1 { temperature = <95000>; hysteresis = <2000>; type = "passive";
@@ -3079,13 +3079,13 @@ thermal-sensors = <&tsens0 9>; trips { - cpu6_alert0: trip-point@0 { + cpu6_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "passive"; }; - cpu6_alert1: trip-point@1 { + cpu6_alert1: trip-point1 { temperature = <95000>; hysteresis = <2000>; type = "passive";
@@ -3123,13 +3123,13 @@ thermal-sensors = <&tsens0 10>; trips { - cpu7_alert0: trip-point@0 { + cpu7_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "passive"; }; - cpu7_alert1: trip-point@1 { + cpu7_alert1: trip-point1 { temperature = <95000>; hysteresis = <2000>; type = "passive";
@@ -3167,7 +3167,7 @@ thermal-sensors = <&tsens0 0>; trips { - aoss0_alert0: trip-point@0 { + aoss0_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "hot";
@@ -3182,7 +3182,7 @@ thermal-sensors = <&tsens0 5>; trips { - cluster0_alert0: trip-point@0 { + cluster0_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "hot";
@@ -3202,7 +3202,7 @@ thermal-sensors = <&tsens0 6>; trips { - cluster1_alert0: trip-point@0 { + cluster1_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "hot";
@@ -3222,7 +3222,7 @@ thermal-sensors = <&tsens0 11>; trips { - gpu1_alert0: trip-point@0 { + gpu1_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "hot";
@@ -3237,7 +3237,7 @@ thermal-sensors = <&tsens0 12>; trips { - gpu2_alert0: trip-point@0 { + gpu2_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "hot";
@@ -3252,7 +3252,7 @@ thermal-sensors = <&tsens1 0>; trips { - aoss1_alert0: trip-point@0 { + aoss1_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "hot";
@@ -3267,7 +3267,7 @@ thermal-sensors = <&tsens1 1>; trips { - q6_modem_alert0: trip-point@0 { + q6_modem_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "hot";
@@ -3282,7 +3282,7 @@ thermal-sensors = <&tsens1 2>; trips { - mem_alert0: trip-point@0 { + mem_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "hot";
@@ -3297,7 +3297,7 @@ thermal-sensors = <&tsens1 3>; trips { - wlan_alert0: trip-point@0 { + wlan_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "hot";
@@ -3312,7 +3312,7 @@ thermal-sensors = <&tsens1 4>; trips { - q6_hvx_alert0: trip-point@0 { + q6_hvx_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "hot";
@@ -3327,7 +3327,7 @@ thermal-sensors = <&tsens1 5>; trips { - camera_alert0: trip-point@0 { + camera_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "hot";
@@ -3342,7 +3342,7 @@ thermal-sensors = <&tsens1 6>; trips { - video_alert0: trip-point@0 { + video_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "hot";
@@ -3357,7 +3357,7 @@ thermal-sensors = <&tsens1 7>; trips { - modem_alert0: trip-point@0 { + modem_alert0: trip-point0 { temperature = <90000>; hysteresis = <2000>; type = "hot";
Signature · 1 line
2.20.1
Re: [PATCH 3/5] arm64: dts: qcom: sdm845: remove unit name for thermal trip points
Quoting Vinod Koul (2019-07-22 05:34:20)
Quoted 33 lines
The thermal trip points have unit name but no reg property, so we can remove them
arch/arm64/boot/dts/qcom/sdm845.dtsi:2824.31-2828.7: Warning (
unit_address_vs_reg): /thermal-zones/cpu0-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2830.31-2834.7: Warning (unit_address_vs_reg): /thermal-zones/cpu0-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2868.31-2872.7: Warning (unit_address_vs_reg): /thermal-zones/cpu1-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2874.31-2878.7: Warning (unit_address_vs_reg): /thermal-zones/cpu1-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2912.31-2916.7: Warning (unit_address_vs_reg): /thermal-zones/cpu2-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2918.31-2922.7: Warning (unit_address_vs_reg): /thermal-zones/cpu2-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2956.31-2960.7: Warning (unit_address_vs_reg): /thermal-zones/cpu3-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:2962.31-2966.7: Warning (unit_address_vs_reg): /thermal-zones/cpu3-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3000.31-3004.7: Warning (unit_address_vs_reg): /thermal-zones/cpu4-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3006.31-3010.7: Warning (unit_address_vs_reg): /thermal-zones/cpu4-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3044.31-3048.7: Warning (unit_address_vs_reg): /thermal-zones/cpu5-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3050.31-3054.7: Warning (unit_address_vs_reg): /thermal-zones/cpu5-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3088.31-3092.7: Warning (unit_address_vs_reg): /thermal-zones/cpu6-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3094.31-3098.7: Warning (unit_address_vs_reg): /thermal-zones/cpu6-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3132.31-3136.7: Warning (unit_address_vs_reg): /thermal-zones/cpu7-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3138.31-3142.7: Warning (unit_address_vs_reg): /thermal-zones/cpu7-thermal/trips/trip-point@1: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3176.32-3180.7: Warning (unit_address_vs_reg): /thermal-zones/aoss0-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3191.35-3195.7: Warning (unit_address_vs_reg): /thermal-zones/cluster0-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3211.35-3215.7: Warning (unit_address_vs_reg): /thermal-zones/cluster1-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3231.31-3235.7: Warning (unit_address_vs_reg): /thermal-zones/gpu-thermal-top/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3246.31-3250.7: Warning (unit_address_vs_reg): /thermal-zones/gpu-thermal-bottom/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3261.32-3265.7: Warning (unit_address_vs_reg): /thermal-zones/aoss1-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3276.35-3280.7: Warning (unit_address_vs_reg): /thermal-zones/q6-modem-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3291.30-3295.7: Warning (unit_address_vs_reg): /thermal-zones/mem-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3306.31-3310.7: Warning (unit_address_vs_reg): /thermal-zones/wlan-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3321.33-3325.7: Warning (unit_address_vs_reg): /thermal-zones/q6-hvx-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3336.33-3340.7: Warning (unit_address_vs_reg): /thermal-zones/camera-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3351.32-3355.7: Warning (unit_address_vs_reg): /thermal-zones/video-thermal/trips/trip-point@0: node has a unit name, but no reg property arch/arm64/boot/dts/qcom/sdm845.dtsi:3366.32-3370.7: Warning (unit_address_vs_reg): /thermal-zones/modem-thermal/trips/trip-point@0: node has a unit name, but no reg property
Quoted 2 lines
Signed-off-by Vinod Koul <[email protected]>---
PATCH 4/5 arm64: dts: qcom: sdm845: remove macro from unit name
In reply to Vinod KoulUnit name is supposed to be a number, using a macro with hex value is not recommended, so add the value in unit name.
arch/arm64/boot/dts/qcom/pm8998.dtsi:81.18-84.6: Warning (unit_address_format): /soc/spmi@c440000/pmic@0/adc@3100/adc-chan@0x06: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/pm8998.dtsi:81.18-84.6: Warning (unit_address_format): /soc/spmi@c440000/pmic@0/adc@3100/adc-chan@0x06: unit name should not have leading 0s
--- arch/arm64/boot/dts/qcom/pm8998.dtsi | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
arch/arm64/boot/dts/qcom/pm8998.dtsi +1 -1
@@ -78,7 +78,7 @@ #size-cells = <0>; #io-channel-cells = <1>; - adc-chan@ADC5_DIE_TEMP { + adc-chan@6{ reg = <ADC5_DIE_TEMP>; label = "die_temp"; };
Signature · 1 line
2.20.1
Re: [PATCH 4/5] arm64: dts: qcom: sdm845: remove macro from unit name
Quoted 16 lines · Vinod Koul
Unit name is supposed to be a number, using a macro with hex value is not recommended, so add the value in unit name.
arch/arm64/boot/dts/qcom/pm8998.dtsi:81.18-84.6: Warning (
unit_address_format): /soc/spmi@c440000/pmic@0/adc@3100/adc-chan@0x06: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/pm8998.dtsi:81.18-84.6: Warning (unit_address_format): /soc/spmi@c440000/pmic@0/adc@3100/adc-chan@0x06: unit name should not have leading 0sSigned-off-by Vinod Koul <[email protected]>--- arch/arm64/boot/dts/qcom/pm8998.dtsi | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)arch/arm64/boot/dts/qcom/pm8998.dtsi +0
-0
arch/arm64/boot/dts/qcom/pm8998.dtsi line 81
Quoted 5 lines
arch/arm64/boot/dts/qcom/pm8998.dtsi +1
-1@@ -78,7 +78,7 @@ #size-cells = <0>; #io-channel-cells = <1>; - adc-chan@ADC5_DIE_TEMP { + adc-chan@6{
You dropped the space before the {
;-)
Re: [PATCH 4/5] arm64: dts: qcom: sdm845: remove macro from unit name
Quoted 21 lines · Marc Gonzalez
Quoted 19 lines · Vinod Koul
Unit name is supposed to be a number, using a macro with hex value is not recommended, so add the value in unit name.
arch/arm64/boot/dts/qcom/pm8998.dtsi:81.18-84.6: Warning (
unit_address_format): /soc/spmi@c440000/pmic@0/adc@3100/adc-chan@0x06: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/pm8998.dtsi:81.18-84.6: Warning (unit_address_format): /soc/spmi@c440000/pmic@0/adc@3100/adc-chan@0x06: unit name should not have leading 0sSigned-off-by Vinod Koul <[email protected]>--- arch/arm64/boot/dts/qcom/pm8998.dtsi | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)arch/arm64/boot/dts/qcom/pm8998.dtsi +0
-0@@ -78,7 +78,7 @@ #size-cells = <0>; #io-channel-cells = <1>;
Quoted 4 lines
arch/arm64/boot/dts/qcom/pm8998.dtsi line 81
Quoted 2 lines
arch/arm64/boot/dts/qcom/pm8998.dtsi +1
-1- adc-chan@ADC5_DIE_TEMP { + adc-chan@6{You dropped the space before the {
Oops, will fix it up, thanks for pointing!
Signature · 1 line
~Vinod
PATCH 5/5 arm64: dts: qcom: sdm845-cheza: remove macro from unit name
In reply to Vinod KoulUnit name is supposed to be a number, using a macro with hex value is not recommended, so add the value in unit name.
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:966.16-969.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4d: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:971.16-974.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4e: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:976.16-979.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4f: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:981.16-984.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x50: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:986.16-989.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x51: unit name should not have leading "0x"
--- arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi | 10 +++++----- 1 file changed, 5 insertions(+), 5 deletions(-)
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi +5 -5
@@ -963,27 +963,27 @@ ap_ts_i2c: &i2c14 { }; &pm8998_adc { - adc-chan@ADC5_AMUX_THM1_100K_PU { + adc-chan@4d { reg = <ADC5_AMUX_THM1_100K_PU>; label = "sdm_temp"; }; - adc-chan@ADC5_AMUX_THM2_100K_PU { + adc-chan@4e { reg = <ADC5_AMUX_THM2_100K_PU>; label = "quiet_temp"; }; - adc-chan@ADC5_AMUX_THM3_100K_PU { + adc-chan@4f { reg = <ADC5_AMUX_THM3_100K_PU>; label = "lte_temp_1"; }; - adc-chan@ADC5_AMUX_THM4_100K_PU { + adc-chan@50 { reg = <ADC5_AMUX_THM4_100K_PU>; label = "lte_temp_2"; }; - adc-chan@ADC5_AMUX_THM5_100K_PU { + adc-chan@51 { reg = <ADC5_AMUX_THM5_100K_PU>; label = "charger_temp"; };
Signature · 1 line
2.20.1
Re: [PATCH 5/5] arm64: dts: qcom: sdm845-cheza: remove macro from unit name
Quoted 2 lines · Vinod Koul
Unit name is supposed to be a number, using a macro with hex value is
/s/name/address?
Quoted 18 lines
not recommended, so add the value in unit name.
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:966.16-969.4: Warning (
unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4d: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:971.16-974.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4e: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:976.16-979.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4f: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:981.16-984.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x50: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:986.16-989.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x51: unit name should not have leading "0x"Signed-off-by Vinod Koul <[email protected]>--- arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi | 10 +++++----- 1 file changed, 5 insertions(+), 5 deletions(-)arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi +0
-0
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi ap_ts_i2c: &i2c14 { · line 967
Quoted 6 lines
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi +1
-1@@ -963,27 +963,27 @@ ap_ts_i2c: &i2c14 { }; &pm8998_adc { - adc-chan@ADC5_AMUX_THM1_100K_PU { + adc-chan@4d { reg = <ADC5_AMUX_THM1_100K_PU>;
I'm a little conflicted about this change. If we're replacing the address with actual values, perhaps we should do that same for the reg property to keep them in sync? Admittedly though, it is a bit easier to read the macro name and figure out its meaning.
Quoted 29 lines
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi +4
-5label = "sdm_temp"; }; - adc-chan@ADC5_AMUX_THM2_100K_PU { + adc-chan@4e { reg = <ADC5_AMUX_THM2_100K_PU>; label = "quiet_temp"; }; - adc-chan@ADC5_AMUX_THM3_100K_PU { + adc-chan@4f { reg = <ADC5_AMUX_THM3_100K_PU>; label = "lte_temp_1"; }; - adc-chan@ADC5_AMUX_THM4_100K_PU { + adc-chan@50 { reg = <ADC5_AMUX_THM4_100K_PU>; label = "lte_temp_2"; }; - adc-chan@ADC5_AMUX_THM5_100K_PU { + adc-chan@51 { reg = <ADC5_AMUX_THM5_100K_PU>; label = "charger_temp"; }; --2.20.1
Re: [PATCH 5/5] arm64: dts: qcom: sdm845-cheza: remove macro from unit name
Quoted 5 lines · Amit Kucheria
Quoted 2 lines · Vinod Koul
Unit name is supposed to be a number, using a macro with hex value is
/s/name/address?
Right, will fix.
Quoted 20 lines
Quoted 20 lines
not recommended, so add the value in unit name.
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:966.16-969.4: Warning (
unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4d: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:971.16-974.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4e: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:976.16-979.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4f: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:981.16-984.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x50: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:986.16-989.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x51: unit name should not have leading "0x"Signed-off-by Vinod Koul <[email protected]>--- arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi | 10 +++++----- 1 file changed, 5 insertions(+), 5 deletions(-)arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi +0
-0@@ -963,27 +963,27 @@ ap_ts_i2c: &i2c14 { };
Quoted 9 lines
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi ap_ts_i2c: &i2c14 { · line 967
Quoted 4 lines
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi +1
-1&pm8998_adc { - adc-chan@ADC5_AMUX_THM1_100K_PU { + adc-chan@4d { reg = <ADC5_AMUX_THM1_100K_PU>;I'm a little conflicted about this change. If we're replacing the address with actual values, perhaps we should do that same for the reg property to keep them in sync? Admittedly though, it is a bit easier to read the macro name and figure out its meaning.
Well this was how Bjorn suggested, am okay if we do in any other way. This fixes warning but keeps it bit readable too
Other way would be to make defines decimal values instead of hex
Any better suggestions :)
Signature · 1 line
~Vinod
Re: [PATCH 5/5] arm64: dts: qcom: sdm845-cheza: remove macro from unit name
Quoted 29 lines · Vinod Koul
Quoted 5 lines · Amit Kucheria
Quoted 2 lines · Vinod Koul
Unit name is supposed to be a number, using a macro with hex value is
/s/name/address?
Right, will fix.
Quoted 20 lines
Quoted 20 lines
not recommended, so add the value in unit name.
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:966.16-969.4: Warning (
unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4d: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:971.16-974.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4e: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:976.16-979.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4f: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:981.16-984.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x50: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:986.16-989.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x51: unit name should not have leading "0x"Signed-off-by Vinod Koul <[email protected]>--- arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi | 10 +++++----- 1 file changed, 5 insertions(+), 5 deletions(-)arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi +0
-0@@ -963,27 +963,27 @@ ap_ts_i2c: &i2c14 { };
Quoted 4 lines
Quoted 4 lines
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi ap_ts_i2c: &i2c14 { · line 967
Quoted 4 lines
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi +1
-1&pm8998_adc { - adc-chan@ADC5_AMUX_THM1_100K_PU { + adc-chan@4d { reg = <ADC5_AMUX_THM1_100K_PU>;
When I read this define I instantly know which channel we're referring to. The 4d above is simply there for syntactical purposes and needs only to be cared about if the reg is ever changed.
So I like this form.
Quoted 11 lines
Quoted 5 lines
I'm a little conflicted about this change. If we're replacing the address with actual values, perhaps we should do that same for the reg property to keep them in sync? Admittedly though, it is a bit easier to read the macro name and figure out its meaning.
Well this was how Bjorn suggested, am okay if we do in any other way. This fixes warning but keeps it bit readable too
Other way would be to make defines decimal values instead of hex
While the ePAPRR states that the unit address must match the first reg, dtc enforces that the unit address string matches "%x" of the reg.
Regards,
Bjorn
Quoted 4 lines
Any better suggestions :)
Signature · 1 line
~Vinod
Re: [PATCH 5/5] arm64: dts: qcom: sdm845-cheza: remove macro from unit name
In reply to Vinod KoulQuoting Vinod Koul (2019-07-22 05:34:22)
Quoted 11 lines
Unit name is supposed to be a number, using a macro with hex value is not recommended, so add the value in unit name.
arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:966.16-969.4: Warning (
unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4d: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:971.16-974.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4e: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:976.16-979.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x4f: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:981.16-984.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x50: unit name should not have leading "0x" arch/arm64/boot/dts/qcom/sdm845-cheza.dtsi:986.16-989.4: Warning (unit_address_format): /soc@0/spmi@c440000/pmic@0/adc@3100/adc-chan@0x51: unit name should not have leading "0x"Signed-off-by Vinod Koul <[email protected]>---